Cargando…

Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?

OBJECTIVE: Successful results after one-stage trans-anal pull-through (OSTAPT) operation for Hirschsprung's disease (HD) depend on accurate identification of the aganglionic segment in intra-operative frozen section (FS). Misinterpretation of the findings of the rectal biopsy is an anxiety-evok...

Descripción completa

Detalles Bibliográficos
Autores principales: Rouzrokh, Mohsen, Jadali, Farzaneh, Gharib, Atoosa, Khaleghnejad-Tabari, Ahmad, Tavassoli, Azita, Mohajerzadeh, Leily
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3446099/
https://www.ncbi.nlm.nih.gov/pubmed/23056767
_version_ 1782243907139010560
author Rouzrokh, Mohsen
Jadali, Farzaneh
Gharib, Atoosa
Khaleghnejad-Tabari, Ahmad
Tavassoli, Azita
Mohajerzadeh, Leily
author_facet Rouzrokh, Mohsen
Jadali, Farzaneh
Gharib, Atoosa
Khaleghnejad-Tabari, Ahmad
Tavassoli, Azita
Mohajerzadeh, Leily
author_sort Rouzrokh, Mohsen
collection PubMed
description OBJECTIVE: Successful results after one-stage trans-anal pull-through (OSTAPT) operation for Hirschsprung's disease (HD) depend on accurate identification of the aganglionic segment in intra-operative frozen section (FS). Misinterpretation of the findings of the rectal biopsy is an anxiety-evoking pitfall for the surgeon. This study aims to describe our experiences in comparing results of FS and permanent Section (PS) rectal biopsies in children with HD who were candidates for OSTAPT in a single-step operation. METHODS: Subjects under the age of 14 years, admitted from March 2000 to July 2008 in a university-affiliated children's hospital for open rectal biopsy to diagnose HD were included in the study. All biopsies were taken 2–3 cm above the dentate line. 210 specimens of full-thickness rectal biopsy were obtained for both frozen section and permanent biopsy from all patients, examined by two well experienced pediatric pathologists for ascertaining the presence of ganglion cells, and the results were compared. Analysis was performed by SPSS Software version 11.5. FINDINGS: Two-hundred one infants and children underwent FS rectal biopsy to exclude HD. Positive results were seen in 63.8% of the specimens examined as PS and in 58.3% of FS samples. 93.9% of positive results in FS studies were confirmed by PS studies. 6.1% of FS reports were false positive and 21.7% were false negative (P<0.001). The sensitivity of FS was 85.8% and specificity 90.2%. Positive predictive value (PPV) was 93.9% and negative predictive value (NPV) was 78.3% in FS studies (P<0.001). The accuracy of FS was 80.4%. CONCLUSION: Although FS of the rectal biopsy is useful in defining the aganglionic segment during operation, according to this study, it cannot be used as the sole base for performing primary pull-through operation before the results of the permanent section are on hand.
format Online
Article
Text
id pubmed-3446099
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-34460992012-10-09 Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease? Rouzrokh, Mohsen Jadali, Farzaneh Gharib, Atoosa Khaleghnejad-Tabari, Ahmad Tavassoli, Azita Mohajerzadeh, Leily Iran J Pediatr Original Article OBJECTIVE: Successful results after one-stage trans-anal pull-through (OSTAPT) operation for Hirschsprung's disease (HD) depend on accurate identification of the aganglionic segment in intra-operative frozen section (FS). Misinterpretation of the findings of the rectal biopsy is an anxiety-evoking pitfall for the surgeon. This study aims to describe our experiences in comparing results of FS and permanent Section (PS) rectal biopsies in children with HD who were candidates for OSTAPT in a single-step operation. METHODS: Subjects under the age of 14 years, admitted from March 2000 to July 2008 in a university-affiliated children's hospital for open rectal biopsy to diagnose HD were included in the study. All biopsies were taken 2–3 cm above the dentate line. 210 specimens of full-thickness rectal biopsy were obtained for both frozen section and permanent biopsy from all patients, examined by two well experienced pediatric pathologists for ascertaining the presence of ganglion cells, and the results were compared. Analysis was performed by SPSS Software version 11.5. FINDINGS: Two-hundred one infants and children underwent FS rectal biopsy to exclude HD. Positive results were seen in 63.8% of the specimens examined as PS and in 58.3% of FS samples. 93.9% of positive results in FS studies were confirmed by PS studies. 6.1% of FS reports were false positive and 21.7% were false negative (P<0.001). The sensitivity of FS was 85.8% and specificity 90.2%. Positive predictive value (PPV) was 93.9% and negative predictive value (NPV) was 78.3% in FS studies (P<0.001). The accuracy of FS was 80.4%. CONCLUSION: Although FS of the rectal biopsy is useful in defining the aganglionic segment during operation, according to this study, it cannot be used as the sole base for performing primary pull-through operation before the results of the permanent section are on hand. Tehran University of Medical Sciences 2011-03 /pmc/articles/PMC3446099/ /pubmed/23056767 Text en © 2011 Iranian Journal of Pediatrics & Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Rouzrokh, Mohsen
Jadali, Farzaneh
Gharib, Atoosa
Khaleghnejad-Tabari, Ahmad
Tavassoli, Azita
Mohajerzadeh, Leily
Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title_full Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title_fullStr Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title_full_unstemmed Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title_short Can We Rely on Frozen Sections of a Rectal Biopsy for One-stage Trans-anal Pull-through Operation in Hirschsprung's Disease?
title_sort can we rely on frozen sections of a rectal biopsy for one-stage trans-anal pull-through operation in hirschsprung's disease?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3446099/
https://www.ncbi.nlm.nih.gov/pubmed/23056767
work_keys_str_mv AT rouzrokhmohsen canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease
AT jadalifarzaneh canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease
AT gharibatoosa canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease
AT khaleghnejadtabariahmad canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease
AT tavassoliazita canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease
AT mohajerzadehleily canwerelyonfrozensectionsofarectalbiopsyforonestagetransanalpullthroughoperationinhirschsprungsdisease