Cargando…
Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope
Three-dimensional second-harmonic fields, sample orientation, and susceptibility ratios of biological samples are measured using polarization-resolved second-harmonic generation (SHG) microscopy. The three-dimensional (3D) polarization is gathered by measurement of a series of holograms for which ex...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3447544/ https://www.ncbi.nlm.nih.gov/pubmed/23024896 http://dx.doi.org/10.1364/BOE.3.002004 |
_version_ | 1782244108521177088 |
---|---|
author | Winters, David G. Smith, David R. Schlup, Philip Bartels, Randy A. |
author_facet | Winters, David G. Smith, David R. Schlup, Philip Bartels, Randy A. |
author_sort | Winters, David G. |
collection | PubMed |
description | Three-dimensional second-harmonic fields, sample orientation, and susceptibility ratios of biological samples are measured using polarization-resolved second-harmonic generation (SHG) microscopy. The three-dimensional (3D) polarization is gathered by measurement of a series of holograms for which excitation and analyzer polarizations are systematically varied, and the 3D SHG field is recovered through numerical back propagation. Harmonophore orientation is resolved in 3D from a sub-set of polarization-resolved SHG holograms. We further expand on previous approaches for the determination of susceptibility ratios, adding the calculation of multiple ratio values to allow intrinsic verification. |
format | Online Article Text |
id | pubmed-3447544 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-34475442012-09-28 Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope Winters, David G. Smith, David R. Schlup, Philip Bartels, Randy A. Biomed Opt Express Microscopy Three-dimensional second-harmonic fields, sample orientation, and susceptibility ratios of biological samples are measured using polarization-resolved second-harmonic generation (SHG) microscopy. The three-dimensional (3D) polarization is gathered by measurement of a series of holograms for which excitation and analyzer polarizations are systematically varied, and the 3D SHG field is recovered through numerical back propagation. Harmonophore orientation is resolved in 3D from a sub-set of polarization-resolved SHG holograms. We further expand on previous approaches for the determination of susceptibility ratios, adding the calculation of multiple ratio values to allow intrinsic verification. Optical Society of America 2012-08-03 /pmc/articles/PMC3447544/ /pubmed/23024896 http://dx.doi.org/10.1364/BOE.3.002004 Text en © 2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Microscopy Winters, David G. Smith, David R. Schlup, Philip Bartels, Randy A. Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title | Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title_full | Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title_fullStr | Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title_full_unstemmed | Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title_short | Measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
title_sort | measurement of orientation and susceptibility ratios using a polarization-resolved second-harmonic generation holographic microscope |
topic | Microscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3447544/ https://www.ncbi.nlm.nih.gov/pubmed/23024896 http://dx.doi.org/10.1364/BOE.3.002004 |
work_keys_str_mv | AT wintersdavidg measurementoforientationandsusceptibilityratiosusingapolarizationresolvedsecondharmonicgenerationholographicmicroscope AT smithdavidr measurementoforientationandsusceptibilityratiosusingapolarizationresolvedsecondharmonicgenerationholographicmicroscope AT schlupphilip measurementoforientationandsusceptibilityratiosusingapolarizationresolvedsecondharmonicgenerationholographicmicroscope AT bartelsrandya measurementoforientationandsusceptibilityratiosusingapolarizationresolvedsecondharmonicgenerationholographicmicroscope |