A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices

PURPOSE: To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices. METHODS: Thirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qinmei, Savini, Giacomo, Hoffer, Kenneth J., Xu, Zhen, Feng, Yifan, Wen, Daizong, Hua, Yanjun, Yang, Feng, Pan, Chao, Huang, Jinhai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458095/
https://www.ncbi.nlm.nih.gov/pubmed/23049823
http://dx.doi.org/10.1371/journal.pone.0045607
_version_ 1782244626846973952
author Wang, Qinmei
Savini, Giacomo
Hoffer, Kenneth J.
Xu, Zhen
Feng, Yifan
Wen, Daizong
Hua, Yanjun
Yang, Feng
Pan, Chao
Huang, Jinhai
author_facet Wang, Qinmei
Savini, Giacomo
Hoffer, Kenneth J.
Xu, Zhen
Feng, Yifan
Wen, Daizong
Hua, Yanjun
Yang, Feng
Pan, Chao
Huang, Jinhai
author_sort Wang, Qinmei
collection PubMed
description PURPOSE: To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices. METHODS: Thirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measurements with the RC-5000 (Tomey Corp., Japan), KR-8000 (Topcon, Japan), IOLMaster (Carl Zeiss Meditec, Germany), E300 (Medmont International, Australia), Allegro Topolyzer (Wavelight AG, Germany), Vista (EyeSys, TX), Pentacam (Oculus, Germany) and Sirius (CSO, Italy). Measurements were repeated in the second session (1 to 2 weeks later). Repeatability and reproducibility of corneal power measurements were assessed based on the intrasession and intersession within-subject standard deviation (Sw), repeatability (2.77Sw), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was evaluated by 95% limits of agreement (LoA). RESULTS: All devices demonstrated high repeatability and reproducibility of the keratometric values (2.77Sw<0.36D, COV<0.3%, ICC>0.98). Repeated-measures analysis of variance with Bonferroni post test showed statistically significant differences (P<0.01) among mean keratometric values of most instruments; the largest differences were observed between the EyeSys Vista and Medmont E300. Good agreement (i.e., 95%LoA within ±0.5D) was found between most instruments for flat, steep and mean keratometry, except for EyeSys and Medmont. Repeatability and reproducibility of vectors J(0) and J(45) was good, as the ICCs were higher than 0.9, except J(45) of Medmont and Pentacam. For the 95% LoAs of J(0) and J(45), they were all ≤ ±0.31 among any two paired devices. CONCLUSIONS: The 8 devices showed excellent repeatability and reproducibility. The results obtained using the RC-5000, KR-8000, IOLMaster, Allegro Topolyzer, Pentacam and Sirius were comparable, suggesting that they could be used interchangeably in most clinical settings. Caution is warranted with the measurements of the EyeSys Vista and Medmont E300, which should not be used interchangeably with other devices due to lower agreement. TRIAL REGISTRATION: ClinicalTrials.gov NCT01587287
format Online
Article
Text
id pubmed-3458095
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34580952012-10-03 A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices Wang, Qinmei Savini, Giacomo Hoffer, Kenneth J. Xu, Zhen Feng, Yifan Wen, Daizong Hua, Yanjun Yang, Feng Pan, Chao Huang, Jinhai PLoS One Research Article PURPOSE: To comprehensively assess the precision and agreement of anterior corneal power measurements using 8 different devices. METHODS: Thirty-five eyes from 35 healthy subjects were included in the prospective study. In the first session, a single examiner performed on each subject randomly measurements with the RC-5000 (Tomey Corp., Japan), KR-8000 (Topcon, Japan), IOLMaster (Carl Zeiss Meditec, Germany), E300 (Medmont International, Australia), Allegro Topolyzer (Wavelight AG, Germany), Vista (EyeSys, TX), Pentacam (Oculus, Germany) and Sirius (CSO, Italy). Measurements were repeated in the second session (1 to 2 weeks later). Repeatability and reproducibility of corneal power measurements were assessed based on the intrasession and intersession within-subject standard deviation (Sw), repeatability (2.77Sw), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was evaluated by 95% limits of agreement (LoA). RESULTS: All devices demonstrated high repeatability and reproducibility of the keratometric values (2.77Sw<0.36D, COV<0.3%, ICC>0.98). Repeated-measures analysis of variance with Bonferroni post test showed statistically significant differences (P<0.01) among mean keratometric values of most instruments; the largest differences were observed between the EyeSys Vista and Medmont E300. Good agreement (i.e., 95%LoA within ±0.5D) was found between most instruments for flat, steep and mean keratometry, except for EyeSys and Medmont. Repeatability and reproducibility of vectors J(0) and J(45) was good, as the ICCs were higher than 0.9, except J(45) of Medmont and Pentacam. For the 95% LoAs of J(0) and J(45), they were all ≤ ±0.31 among any two paired devices. CONCLUSIONS: The 8 devices showed excellent repeatability and reproducibility. The results obtained using the RC-5000, KR-8000, IOLMaster, Allegro Topolyzer, Pentacam and Sirius were comparable, suggesting that they could be used interchangeably in most clinical settings. Caution is warranted with the measurements of the EyeSys Vista and Medmont E300, which should not be used interchangeably with other devices due to lower agreement. TRIAL REGISTRATION: ClinicalTrials.gov NCT01587287 Public Library of Science 2012-09-25 /pmc/articles/PMC3458095/ /pubmed/23049823 http://dx.doi.org/10.1371/journal.pone.0045607 Text en © 2012 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wang, Qinmei
Savini, Giacomo
Hoffer, Kenneth J.
Xu, Zhen
Feng, Yifan
Wen, Daizong
Hua, Yanjun
Yang, Feng
Pan, Chao
Huang, Jinhai
A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title_full A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title_fullStr A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title_full_unstemmed A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title_short A Comprehensive Assessment of the Precision and Agreement of Anterior Corneal Power Measurements Obtained Using 8 Different Devices
title_sort comprehensive assessment of the precision and agreement of anterior corneal power measurements obtained using 8 different devices
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458095/
https://www.ncbi.nlm.nih.gov/pubmed/23049823
http://dx.doi.org/10.1371/journal.pone.0045607
work_keys_str_mv AT wangqinmei acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT savinigiacomo acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT hofferkennethj acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT xuzhen acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT fengyifan acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT wendaizong acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT huayanjun acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT yangfeng acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT panchao acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT huangjinhai acomprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT wangqinmei comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT savinigiacomo comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT hofferkennethj comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT xuzhen comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT fengyifan comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT wendaizong comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT huayanjun comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT yangfeng comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT panchao comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices
AT huangjinhai comprehensiveassessmentoftheprecisionandagreementofanteriorcornealpowermeasurementsobtainedusing8differentdevices