Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure

PURPOSE: Despite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigra...

Descripción completa

Detalles Bibliográficos
Autores principales: Veltman, Caroline E., Boogers, Mark J., Meinardi, Joris E., Al Younis, Imad, Dibbets-Schneider, Petra, Van der Wall, Ernst E., Bax, Jeroen J., Scholte, Arthur J. H. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458210/
https://www.ncbi.nlm.nih.gov/pubmed/22790878
http://dx.doi.org/10.1007/s00259-012-2180-2
_version_ 1782244638823809024
author Veltman, Caroline E.
Boogers, Mark J.
Meinardi, Joris E.
Al Younis, Imad
Dibbets-Schneider, Petra
Van der Wall, Ernst E.
Bax, Jeroen J.
Scholte, Arthur J. H. A.
author_facet Veltman, Caroline E.
Boogers, Mark J.
Meinardi, Joris E.
Al Younis, Imad
Dibbets-Schneider, Petra
Van der Wall, Ernst E.
Bax, Jeroen J.
Scholte, Arthur J. H. A.
author_sort Veltman, Caroline E.
collection PubMed
description PURPOSE: Despite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigraphy in patients with heart failure (HF). METHODS: Planar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI). RESULTS: Intra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar (123)I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were −2.50 to 2.16 and −10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement. CONCLUSION: The present study showed a high reliability of planar (123)I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF.
format Online
Article
Text
id pubmed-3458210
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-34582102013-07-15 Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure Veltman, Caroline E. Boogers, Mark J. Meinardi, Joris E. Al Younis, Imad Dibbets-Schneider, Petra Van der Wall, Ernst E. Bax, Jeroen J. Scholte, Arthur J. H. A. Eur J Nucl Med Mol Imaging Original Article PURPOSE: Despite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigraphy in patients with heart failure (HF). METHODS: Planar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI). RESULTS: Intra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar (123)I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were −2.50 to 2.16 and −10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement. CONCLUSION: The present study showed a high reliability of planar (123)I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF. Springer-Verlag 2012-07-13 2012 /pmc/articles/PMC3458210/ /pubmed/22790878 http://dx.doi.org/10.1007/s00259-012-2180-2 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Veltman, Caroline E.
Boogers, Mark J.
Meinardi, Joris E.
Al Younis, Imad
Dibbets-Schneider, Petra
Van der Wall, Ernst E.
Bax, Jeroen J.
Scholte, Arthur J. H. A.
Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title_full Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title_fullStr Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title_full_unstemmed Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title_short Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure
title_sort reproducibility of planar (123)i-meta-iodobenzylguanidine (mibg) myocardial scintigraphy in patients with heart failure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458210/
https://www.ncbi.nlm.nih.gov/pubmed/22790878
http://dx.doi.org/10.1007/s00259-012-2180-2
work_keys_str_mv AT veltmancarolinee reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT boogersmarkj reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT meinardijorise reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT alyounisimad reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT dibbetsschneiderpetra reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT vanderwallernste reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT baxjeroenj reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure
AT scholtearthurjha reproducibilityofplanar123imetaiodobenzylguanidinemibgmyocardialscintigraphyinpatientswithheartfailure