Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

BACKGROUND: The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclinat...

Descripción completa

Detalles Bibliográficos
Autores principales: Koprowski, Robert, Teper, Sławomir Jan, Węglarz, Beata, Wylęgała, Edward, Krejca, Michał, Wróbel, Zygmunt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458903/
https://www.ncbi.nlm.nih.gov/pubmed/22727245
http://dx.doi.org/10.1186/1475-925X-11-35
_version_ 1782244728969887744
author Koprowski, Robert
Teper, Sławomir Jan
Węglarz, Beata
Wylęgała, Edward
Krejca, Michał
Wróbel, Zygmunt
author_facet Koprowski, Robert
Teper, Sławomir Jan
Węglarz, Beata
Wylęgała, Edward
Krejca, Michał
Wróbel, Zygmunt
author_sort Koprowski, Robert
collection PubMed
description BACKGROUND: The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. METHODS: The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. RESULTS: The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. CONCLUSIONS: This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.
format Online
Article
Text
id pubmed-3458903
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34589032012-09-28 Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus Koprowski, Robert Teper, Sławomir Jan Węglarz, Beata Wylęgała, Edward Krejca, Michał Wróbel, Zygmunt Biomed Eng Online Research BACKGROUND: The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. METHODS: The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. RESULTS: The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. CONCLUSIONS: This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number. BioMed Central 2012-06-22 /pmc/articles/PMC3458903/ /pubmed/22727245 http://dx.doi.org/10.1186/1475-925X-11-35 Text en Copyright ©2012 Koprowski et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Koprowski, Robert
Teper, Sławomir Jan
Węglarz, Beata
Wylęgała, Edward
Krejca, Michał
Wróbel, Zygmunt
Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title_full Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title_fullStr Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title_full_unstemmed Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title_short Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
title_sort fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3458903/
https://www.ncbi.nlm.nih.gov/pubmed/22727245
http://dx.doi.org/10.1186/1475-925X-11-35
work_keys_str_mv AT koprowskirobert fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus
AT tepersławomirjan fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus
AT weglarzbeata fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus
AT wylegałaedward fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus
AT krejcamichał fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus
AT wrobelzygmunt fullyautomaticalgorithmfortheanalysisofvesselsintheangiographicimageoftheeyefundus