Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison
PURPOSE: The incidence of operative treatment of dislocated midshaft clavicle fractures (DMCF) is rising due to unsatisfactory results after non-operative treatment. Knowledge of complications is important for selection of the surgical technique and preoperative patient counselling. The aim of this...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460104/ https://www.ncbi.nlm.nih.gov/pubmed/22847116 http://dx.doi.org/10.1007/s00264-012-1615-5 |
_version_ | 1782244910222540800 |
---|---|
author | Wijdicks, Frans-Jasper Houwert, Marijn Dijkgraaf, Marcel de Lange, Diederik Oosterhuis, Koen Clevers, Geertjan Verleisdonk, Egbert-Jan |
author_facet | Wijdicks, Frans-Jasper Houwert, Marijn Dijkgraaf, Marcel de Lange, Diederik Oosterhuis, Koen Clevers, Geertjan Verleisdonk, Egbert-Jan |
author_sort | Wijdicks, Frans-Jasper |
collection | PubMed |
description | PURPOSE: The incidence of operative treatment of dislocated midshaft clavicle fractures (DMCF) is rising due to unsatisfactory results after non-operative treatment. Knowledge of complications is important for selection of the surgical technique and preoperative patient counselling. The aim of this study is to compare complications after plate fixation and elastic stable intramedullary nailing (ESIN) with a titanium elastic nail (TEN) for DMCF. METHODS: A retrospective analysis of our surgical database was performed. From January 2005 to January 2010, 90 patients with DMCF were treated with plate fixation or ESIN. Complications were evaluated in both treatment groups and subsequently compared. RESULTS: Seven implant failures occurred in six patients (14 %) of the plate group and one implant failure (2.1 %) was seen in the ESIN group (p = 0.051). Major revision surgery was performed in five cases in the plate group (11.6 %) and in one case (2.1 %) in the ESIN group (p = 0.100). Three refractures (7.0 %) were observed in the plate group after removal of the implant against none in the ESIN group (p = 0.105). Six minor revisions (13 %) were reported in the ESIN group and none were reported in the plate group (p = 0.027). CONCLUSIONS: Compared to other studies we report higher rates of refracture (7.0 %), major revision surgery (11.6 %) and implant failure (14.0 %) after plate fixation. The frequency of implant failures differed almost significantly for patients treated with plate fixation compared to ESIN. Furthermore, a tendency towards refracture after implant removal and major revision surgery after plate fixation was observed. |
format | Online Article Text |
id | pubmed-3460104 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-34601042012-11-09 Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison Wijdicks, Frans-Jasper Houwert, Marijn Dijkgraaf, Marcel de Lange, Diederik Oosterhuis, Koen Clevers, Geertjan Verleisdonk, Egbert-Jan Int Orthop Original Paper PURPOSE: The incidence of operative treatment of dislocated midshaft clavicle fractures (DMCF) is rising due to unsatisfactory results after non-operative treatment. Knowledge of complications is important for selection of the surgical technique and preoperative patient counselling. The aim of this study is to compare complications after plate fixation and elastic stable intramedullary nailing (ESIN) with a titanium elastic nail (TEN) for DMCF. METHODS: A retrospective analysis of our surgical database was performed. From January 2005 to January 2010, 90 patients with DMCF were treated with plate fixation or ESIN. Complications were evaluated in both treatment groups and subsequently compared. RESULTS: Seven implant failures occurred in six patients (14 %) of the plate group and one implant failure (2.1 %) was seen in the ESIN group (p = 0.051). Major revision surgery was performed in five cases in the plate group (11.6 %) and in one case (2.1 %) in the ESIN group (p = 0.100). Three refractures (7.0 %) were observed in the plate group after removal of the implant against none in the ESIN group (p = 0.105). Six minor revisions (13 %) were reported in the ESIN group and none were reported in the plate group (p = 0.027). CONCLUSIONS: Compared to other studies we report higher rates of refracture (7.0 %), major revision surgery (11.6 %) and implant failure (14.0 %) after plate fixation. The frequency of implant failures differed almost significantly for patients treated with plate fixation compared to ESIN. Furthermore, a tendency towards refracture after implant removal and major revision surgery after plate fixation was observed. Springer-Verlag 2012-07-31 2012-10 /pmc/articles/PMC3460104/ /pubmed/22847116 http://dx.doi.org/10.1007/s00264-012-1615-5 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Paper Wijdicks, Frans-Jasper Houwert, Marijn Dijkgraaf, Marcel de Lange, Diederik Oosterhuis, Koen Clevers, Geertjan Verleisdonk, Egbert-Jan Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title | Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title_full | Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title_fullStr | Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title_full_unstemmed | Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title_short | Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
title_sort | complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460104/ https://www.ncbi.nlm.nih.gov/pubmed/22847116 http://dx.doi.org/10.1007/s00264-012-1615-5 |
work_keys_str_mv | AT wijdicksfransjasper complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT houwertmarijn complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT dijkgraafmarcel complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT delangediederik complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT oosterhuiskoen complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT cleversgeertjan complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison AT verleisdonkegbertjan complicationsafterplatefixationandelasticstableintramedullarynailingofdislocatedmidshaftclaviclefracturesaretrospectivecomparison |