Cargando…

Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors

Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and pros...

Descripción completa

Detalles Bibliográficos
Autores principales: Alhasan, Mustafa K., Liu, Li, Lewis, Matthew A., Magnusson, Jennifer, Mason, Ralph P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460997/
https://www.ncbi.nlm.nih.gov/pubmed/23029403
http://dx.doi.org/10.1371/journal.pone.0046106
_version_ 1782245027528835072
author Alhasan, Mustafa K.
Liu, Li
Lewis, Matthew A.
Magnusson, Jennifer
Mason, Ralph P.
author_facet Alhasan, Mustafa K.
Liu, Li
Lewis, Matthew A.
Magnusson, Jennifer
Mason, Ralph P.
author_sort Alhasan, Mustafa K.
collection PubMed
description Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO). During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs. The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.
format Online
Article
Text
id pubmed-3460997
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34609972012-10-01 Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors Alhasan, Mustafa K. Liu, Li Lewis, Matthew A. Magnusson, Jennifer Mason, Ralph P. PLoS One Research Article Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO). During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs. The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent. Public Library of Science 2012-09-28 /pmc/articles/PMC3460997/ /pubmed/23029403 http://dx.doi.org/10.1371/journal.pone.0046106 Text en © 2012 Alhasan et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Alhasan, Mustafa K.
Liu, Li
Lewis, Matthew A.
Magnusson, Jennifer
Mason, Ralph P.
Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title_full Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title_fullStr Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title_full_unstemmed Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title_short Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
title_sort comparison of optical and power doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460997/
https://www.ncbi.nlm.nih.gov/pubmed/23029403
http://dx.doi.org/10.1371/journal.pone.0046106
work_keys_str_mv AT alhasanmustafak comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors
AT liuli comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors
AT lewismatthewa comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors
AT magnussonjennifer comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors
AT masonralphp comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors