Cargando…
Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and pros...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460997/ https://www.ncbi.nlm.nih.gov/pubmed/23029403 http://dx.doi.org/10.1371/journal.pone.0046106 |
_version_ | 1782245027528835072 |
---|---|
author | Alhasan, Mustafa K. Liu, Li Lewis, Matthew A. Magnusson, Jennifer Mason, Ralph P. |
author_facet | Alhasan, Mustafa K. Liu, Li Lewis, Matthew A. Magnusson, Jennifer Mason, Ralph P. |
author_sort | Alhasan, Mustafa K. |
collection | PubMed |
description | Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO). During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs. The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent. |
format | Online Article Text |
id | pubmed-3460997 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-34609972012-10-01 Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors Alhasan, Mustafa K. Liu, Li Lewis, Matthew A. Magnusson, Jennifer Mason, Ralph P. PLoS One Research Article Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO). During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs. The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent. Public Library of Science 2012-09-28 /pmc/articles/PMC3460997/ /pubmed/23029403 http://dx.doi.org/10.1371/journal.pone.0046106 Text en © 2012 Alhasan et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Alhasan, Mustafa K. Liu, Li Lewis, Matthew A. Magnusson, Jennifer Mason, Ralph P. Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title | Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title_full | Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title_fullStr | Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title_full_unstemmed | Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title_short | Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors |
title_sort | comparison of optical and power doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3460997/ https://www.ncbi.nlm.nih.gov/pubmed/23029403 http://dx.doi.org/10.1371/journal.pone.0046106 |
work_keys_str_mv | AT alhasanmustafak comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors AT liuli comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors AT lewismatthewa comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors AT magnussonjennifer comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors AT masonralphp comparisonofopticalandpowerdopplerultrasoundimagingfornoninvasiveevaluationofarsenictrioxideasavasculardisruptingagentintumors |