Cargando…

Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection

Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Met...

Descripción completa

Detalles Bibliográficos
Autor principal: Zdansky, Karel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3462130/
https://www.ncbi.nlm.nih.gov/pubmed/22824169
http://dx.doi.org/10.1186/1556-276X-7-415
_version_ 1782245143563206656
author Zdansky, Karel
author_facet Zdansky, Karel
author_sort Zdansky, Karel
collection PubMed
description Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Metal nanoparticles were deposited electrophoretically from colloids prepared beforehand. Deposited nanoparticles were imaged by scanning electron microscopy, atomic force microscopy, and scanning tunneling microscopy on the as-made and annealed-in-vacuum samples. Current–voltage characteristics of prepared Schottky diodes had very high rectification ratios, better than 10(7) at 1 V. It was shown that the barrier heights of these diodes were equal to the difference between the electron affinity of InP or GaN and the electron work function of the metal Pd or Pt (Schottky-Mott limit). That was a good precondition for the high sensitivity of the diodes to hydrogen, and indeed, high sensitivity to hydrogen, with the detection limit better than 1 ppm, was proved.
format Online
Article
Text
id pubmed-3462130
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-34621302012-10-02 Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection Zdansky, Karel Nanoscale Res Lett Nano Express Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Metal nanoparticles were deposited electrophoretically from colloids prepared beforehand. Deposited nanoparticles were imaged by scanning electron microscopy, atomic force microscopy, and scanning tunneling microscopy on the as-made and annealed-in-vacuum samples. Current–voltage characteristics of prepared Schottky diodes had very high rectification ratios, better than 10(7) at 1 V. It was shown that the barrier heights of these diodes were equal to the difference between the electron affinity of InP or GaN and the electron work function of the metal Pd or Pt (Schottky-Mott limit). That was a good precondition for the high sensitivity of the diodes to hydrogen, and indeed, high sensitivity to hydrogen, with the detection limit better than 1 ppm, was proved. Springer 2012-07-23 /pmc/articles/PMC3462130/ /pubmed/22824169 http://dx.doi.org/10.1186/1556-276X-7-415 Text en Copyright ©2012 Zdansky.; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Nano Express
Zdansky, Karel
Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title_full Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title_fullStr Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title_full_unstemmed Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title_short Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
title_sort graphite/inp and graphite/gan schottky barriers with electrophoretically deposited pd or pt nanoparticles for hydrogen detection
topic Nano Express
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3462130/
https://www.ncbi.nlm.nih.gov/pubmed/22824169
http://dx.doi.org/10.1186/1556-276X-7-415
work_keys_str_mv AT zdanskykarel graphiteinpandgraphiteganschottkybarrierswithelectrophoreticallydepositedpdorptnanoparticlesforhydrogendetection