Cargando…
Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Met...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3462130/ https://www.ncbi.nlm.nih.gov/pubmed/22824169 http://dx.doi.org/10.1186/1556-276X-7-415 |
_version_ | 1782245143563206656 |
---|---|
author | Zdansky, Karel |
author_facet | Zdansky, Karel |
author_sort | Zdansky, Karel |
collection | PubMed |
description | Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Metal nanoparticles were deposited electrophoretically from colloids prepared beforehand. Deposited nanoparticles were imaged by scanning electron microscopy, atomic force microscopy, and scanning tunneling microscopy on the as-made and annealed-in-vacuum samples. Current–voltage characteristics of prepared Schottky diodes had very high rectification ratios, better than 10(7) at 1 V. It was shown that the barrier heights of these diodes were equal to the difference between the electron affinity of InP or GaN and the electron work function of the metal Pd or Pt (Schottky-Mott limit). That was a good precondition for the high sensitivity of the diodes to hydrogen, and indeed, high sensitivity to hydrogen, with the detection limit better than 1 ppm, was proved. |
format | Online Article Text |
id | pubmed-3462130 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer |
record_format | MEDLINE/PubMed |
spelling | pubmed-34621302012-10-02 Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection Zdansky, Karel Nanoscale Res Lett Nano Express Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Metal nanoparticles were deposited electrophoretically from colloids prepared beforehand. Deposited nanoparticles were imaged by scanning electron microscopy, atomic force microscopy, and scanning tunneling microscopy on the as-made and annealed-in-vacuum samples. Current–voltage characteristics of prepared Schottky diodes had very high rectification ratios, better than 10(7) at 1 V. It was shown that the barrier heights of these diodes were equal to the difference between the electron affinity of InP or GaN and the electron work function of the metal Pd or Pt (Schottky-Mott limit). That was a good precondition for the high sensitivity of the diodes to hydrogen, and indeed, high sensitivity to hydrogen, with the detection limit better than 1 ppm, was proved. Springer 2012-07-23 /pmc/articles/PMC3462130/ /pubmed/22824169 http://dx.doi.org/10.1186/1556-276X-7-415 Text en Copyright ©2012 Zdansky.; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Nano Express Zdansky, Karel Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title | Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title_full | Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title_fullStr | Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title_full_unstemmed | Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title_short | Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection |
title_sort | graphite/inp and graphite/gan schottky barriers with electrophoretically deposited pd or pt nanoparticles for hydrogen detection |
topic | Nano Express |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3462130/ https://www.ncbi.nlm.nih.gov/pubmed/22824169 http://dx.doi.org/10.1186/1556-276X-7-415 |
work_keys_str_mv | AT zdanskykarel graphiteinpandgraphiteganschottkybarrierswithelectrophoreticallydepositedpdorptnanoparticlesforhydrogendetection |