Cargando…

Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq

BACKGROUND: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Marzoki, Jasim M, Al-Maaroof, Zainab W, Kadhum, Ali H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3464059/
https://www.ncbi.nlm.nih.gov/pubmed/23055785
http://dx.doi.org/10.2147/JBM.S35895
_version_ 1782245356847759360
author Al-Marzoki, Jasim M
Al-Maaroof, Zainab W
Kadhum, Ali H
author_facet Al-Marzoki, Jasim M
Al-Maaroof, Zainab W
Kadhum, Ali H
author_sort Al-Marzoki, Jasim M
collection PubMed
description BACKGROUND: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. METHODS: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. RESULTS: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. CONCLUSION: Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from different areas in Iraq.
format Online
Article
Text
id pubmed-3464059
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-34640592012-10-09 Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq Al-Marzoki, Jasim M Al-Maaroof, Zainab W Kadhum, Ali H J Blood Med Original Research BACKGROUND: The health of an individual is known to vary in different countries, in the same country at different times, and in the same individuals at different ages. This means that the condition of individuals must be related to or compared with reference data. Determination of a reference range for the healthy term newborn is clinically important in terms of various complete blood count parameters. The purpose of this study was to establish a local reference range for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq. METHODS: A total of 220 mothers and their neonates were enrolled in this cross-sectional study from February 2011 to January 2012. Maternal inclusion criteria were age 15–45 years, an uneventful pregnancy, and hemoglobin ≥ 10 g. Neonatal inclusion criteria were full term (37–42 weeks) and normal birth weight. The umbilical cord was immediately clamped after delivery of the baby; 3 mL of cord blood was then taken from the umbilical vein and collected in a tube containing ethylenediamine tetra-acetic acid, its plasma was analyzed for full blood count parameters by standard Coulter gram, and the differential leukocyte count was done manually. RESULTS: Mean neonatal hemoglobin was 13.88 ± 1.34 (range 11–17.3) g/dL and mean white cell count was 10.12 ± 2.8 (range 3.1–21.6) × 109/L. Mean platelet count was 267.63 ± 60.62 (range 152–472) × 109/L. No significant differences in red cell, white cell, or platelet counts were found between males and females, except for neutrophil count. The current study shows lower levels of hemoglobin, white cells, and red cells compared with other studies, and there is agreement with some studies and disagreement with others concerning platelet count. CONCLUSION: Most results in the current study were within the reference range. The hematological reference values for Iraqi neonatal cord plasma need to be confirmed by larger numbers of blood samples and by collecting samples from different areas in Iraq. Dove Medical Press 2012-10-01 /pmc/articles/PMC3464059/ /pubmed/23055785 http://dx.doi.org/10.2147/JBM.S35895 Text en © 2012 Al-Marzoki et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Al-Marzoki, Jasim M
Al-Maaroof, Zainab W
Kadhum, Ali H
Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title_full Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title_fullStr Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title_full_unstemmed Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title_short Determination of reference ranges for full blood count parameters in neonatal cord plasma in Hilla, Babil, Iraq
title_sort determination of reference ranges for full blood count parameters in neonatal cord plasma in hilla, babil, iraq
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3464059/
https://www.ncbi.nlm.nih.gov/pubmed/23055785
http://dx.doi.org/10.2147/JBM.S35895
work_keys_str_mv AT almarzokijasimm determinationofreferencerangesforfullbloodcountparametersinneonatalcordplasmainhillababiliraq
AT almaaroofzainabw determinationofreferencerangesforfullbloodcountparametersinneonatalcordplasmainhillababiliraq
AT kadhumalih determinationofreferencerangesforfullbloodcountparametersinneonatalcordplasmainhillababiliraq