Cargando…
Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes
PURPOSE: We evaluated ocular optical components and their interrelationships in myopic Korean patients. METHODS: In this prospective observational study, 1,011 consecutive patients were recruited from a refractive surgery clinic. The best-corrected visual acuity was >20 / 20 in all patients. The...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Ophthalmological Society
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3464315/ https://www.ncbi.nlm.nih.gov/pubmed/23060718 http://dx.doi.org/10.3341/kjo.2012.26.5.324 |
_version_ | 1782245407484542976 |
---|---|
author | Lee, Sangkyu Kim, Boyun Oh, Tae-Hoon Kim, Hyun Seung |
author_facet | Lee, Sangkyu Kim, Boyun Oh, Tae-Hoon Kim, Hyun Seung |
author_sort | Lee, Sangkyu |
collection | PubMed |
description | PURPOSE: We evaluated ocular optical components and their interrelationships in myopic Korean patients. METHODS: In this prospective observational study, 1,011 consecutive patients were recruited from a refractive surgery clinic. The best-corrected visual acuity was >20 / 20 in all patients. The refractive error, axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were measured by an autorefractor and partial coherence laser interferometry (IOL Master). Central corneal thickness (CCT) was measured by ORBscan II topography. RESULTS: The refractive errors had a positive correlation with LT but negative correlations with AL, ACD, VCD, and CCT. As the axial length increased, the ACD, VCD, and CCT increased but the LT decreased. The CCT had a positive correlation with gender, refractive errors, ACD, VCD, and AL but no correlation with age. The mean CCT was increased in proportion to the increase in AL. CONCLUSIONS: In myopic Korean patients, as axial elongation progressed, the VCD and ACD deepened and the CCT thickened but the LT decreased. The CCT had a positive correlation with the degree of myopia and the AL. |
format | Online Article Text |
id | pubmed-3464315 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Ophthalmological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-34643152012-10-11 Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes Lee, Sangkyu Kim, Boyun Oh, Tae-Hoon Kim, Hyun Seung Korean J Ophthalmol Original Article PURPOSE: We evaluated ocular optical components and their interrelationships in myopic Korean patients. METHODS: In this prospective observational study, 1,011 consecutive patients were recruited from a refractive surgery clinic. The best-corrected visual acuity was >20 / 20 in all patients. The refractive error, axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were measured by an autorefractor and partial coherence laser interferometry (IOL Master). Central corneal thickness (CCT) was measured by ORBscan II topography. RESULTS: The refractive errors had a positive correlation with LT but negative correlations with AL, ACD, VCD, and CCT. As the axial length increased, the ACD, VCD, and CCT increased but the LT decreased. The CCT had a positive correlation with gender, refractive errors, ACD, VCD, and AL but no correlation with age. The mean CCT was increased in proportion to the increase in AL. CONCLUSIONS: In myopic Korean patients, as axial elongation progressed, the VCD and ACD deepened and the CCT thickened but the LT decreased. The CCT had a positive correlation with the degree of myopia and the AL. The Korean Ophthalmological Society 2012-10 2012-09-24 /pmc/articles/PMC3464315/ /pubmed/23060718 http://dx.doi.org/10.3341/kjo.2012.26.5.324 Text en © 2012 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Sangkyu Kim, Boyun Oh, Tae-Hoon Kim, Hyun Seung Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title | Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title_full | Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title_fullStr | Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title_full_unstemmed | Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title_short | Correlations between Magnitude of Refractive Error and Other Optical Components in Korean Myopes |
title_sort | correlations between magnitude of refractive error and other optical components in korean myopes |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3464315/ https://www.ncbi.nlm.nih.gov/pubmed/23060718 http://dx.doi.org/10.3341/kjo.2012.26.5.324 |
work_keys_str_mv | AT leesangkyu correlationsbetweenmagnitudeofrefractiveerrorandotheropticalcomponentsinkoreanmyopes AT kimboyun correlationsbetweenmagnitudeofrefractiveerrorandotheropticalcomponentsinkoreanmyopes AT ohtaehoon correlationsbetweenmagnitudeofrefractiveerrorandotheropticalcomponentsinkoreanmyopes AT kimhyunseung correlationsbetweenmagnitudeofrefractiveerrorandotheropticalcomponentsinkoreanmyopes |