Cargando…

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

PURPOSE: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of...

Descripción completa

Detalles Bibliográficos
Autores principales: Huh, Young-June, Choi, Bo-Ram, Huh, Kyung-Hoe, Yi, Won-Jin, Heo, Min-Suk, Lee, Sam-Sun, Choi, Soon-Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3465755/
https://www.ncbi.nlm.nih.gov/pubmed/23071963
http://dx.doi.org/10.5624/isd.2012.42.3.139
_version_ 1782245576911355904
author Huh, Young-June
Choi, Bo-Ram
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Lee, Sam-Sun
Choi, Soon-Chul
author_facet Huh, Young-June
Choi, Bo-Ram
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Lee, Sam-Sun
Choi, Soon-Chul
author_sort Huh, Young-June
collection PubMed
description PURPOSE: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. MATERIALS AND METHODS: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. RESULTS: The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16°, 0.57±0.15°, respectively. However, for the two different angulations in each group, the 20° angulation showed a greater error in the deviation of the entry point than did the 10° angulation. CONCLUSION: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.
format Online
Article
Text
id pubmed-3465755
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-34657552012-10-15 In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants Huh, Young-June Choi, Bo-Ram Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Lee, Sam-Sun Choi, Soon-Chul Imaging Sci Dent Original Article PURPOSE: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. MATERIALS AND METHODS: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. RESULTS: The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16°, 0.57±0.15°, respectively. However, for the two different angulations in each group, the 20° angulation showed a greater error in the deviation of the entry point than did the 10° angulation. CONCLUSION: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort. Korean Academy of Oral and Maxillofacial Radiology 2012-09 2012-09-21 /pmc/articles/PMC3465755/ /pubmed/23071963 http://dx.doi.org/10.5624/isd.2012.42.3.139 Text en Copyright © 2012 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Huh, Young-June
Choi, Bo-Ram
Huh, Kyung-Hoe
Yi, Won-Jin
Heo, Min-Suk
Lee, Sam-Sun
Choi, Soon-Chul
In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title_full In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title_fullStr In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title_full_unstemmed In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title_short In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
title_sort in-vitro study on the accuracy of a simple-design ct-guided stent for dental implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3465755/
https://www.ncbi.nlm.nih.gov/pubmed/23071963
http://dx.doi.org/10.5624/isd.2012.42.3.139
work_keys_str_mv AT huhyoungjune invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT choiboram invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT huhkyunghoe invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT yiwonjin invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT heominsuk invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT leesamsun invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants
AT choisoonchul invitrostudyontheaccuracyofasimpledesignctguidedstentfordentalimplants