Cargando…

Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector

BACKGROUND: Cynanchum paniculatum Kitagawa belongs to Asclepiadaceae and was used in traditional medicine to invigorate blood, alleviate edema, relieve pain, and relieve toxicity for a long time. OBJECTIVE: A novel and reliable high performance liquid chromatography coupled with diode array detector...

Descripción completa

Detalles Bibliográficos
Autores principales: Weon, Jin Bae, Lee, Bohyoung, Yun, Bo-Ra, Lee, Jiwoo, Ma, Choong Je
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466459/
https://www.ncbi.nlm.nih.gov/pubmed/23060698
http://dx.doi.org/10.4103/0973-1296.99289
_version_ 1782245688704237568
author Weon, Jin Bae
Lee, Bohyoung
Yun, Bo-Ra
Lee, Jiwoo
Ma, Choong Je
author_facet Weon, Jin Bae
Lee, Bohyoung
Yun, Bo-Ra
Lee, Jiwoo
Ma, Choong Je
author_sort Weon, Jin Bae
collection PubMed
description BACKGROUND: Cynanchum paniculatum Kitagawa belongs to Asclepiadaceae and was used in traditional medicine to invigorate blood, alleviate edema, relieve pain, and relieve toxicity for a long time. OBJECTIVE: A novel and reliable high performance liquid chromatography coupled with diode array detector method has been established for simultaneous determination of 10 bioactive compounds isolated from Cynanchum paniculatum Kitagawa, one of the herbal medicines. MATERIALS AND METHODS: The chromatography analysis was performed on a SHISEIDO C(18) column (S-5 μm, 4.6 mm I.D. × 250 mm) at 35°C with a gradient elution of acetonitrile and water at a flow rate of 1ml/min and UV detection at 210, 230, and 280 nm. RESULTS: The method was validated for linearity, precision, and accuracy. All calibration curves showed good linear regression (r(2) > 0.9996). Limits of detection (LOD) and limits of quantification (LOQ) fell in the ranges 0.01 - 0.28 μg/ml and 0.04 - 0.83 μg/ml, respectively. The relative standard deviation (RSD) of the intra- and inter- day test, precision test were within 1.92% and 2.43%, respectively. The mean recovery of all ranged from 92.82 to 107.96% with RSD values 0.12 - 2.18%. CONCLUSION: The results of validation appeared that this established method was very accurate and stabilized for the quantification of 10 bioactive compounds isolated from C. paniculatum.
format Online
Article
Text
id pubmed-3466459
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-34664592012-10-11 Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector Weon, Jin Bae Lee, Bohyoung Yun, Bo-Ra Lee, Jiwoo Ma, Choong Je Pharmacogn Mag Original Article BACKGROUND: Cynanchum paniculatum Kitagawa belongs to Asclepiadaceae and was used in traditional medicine to invigorate blood, alleviate edema, relieve pain, and relieve toxicity for a long time. OBJECTIVE: A novel and reliable high performance liquid chromatography coupled with diode array detector method has been established for simultaneous determination of 10 bioactive compounds isolated from Cynanchum paniculatum Kitagawa, one of the herbal medicines. MATERIALS AND METHODS: The chromatography analysis was performed on a SHISEIDO C(18) column (S-5 μm, 4.6 mm I.D. × 250 mm) at 35°C with a gradient elution of acetonitrile and water at a flow rate of 1ml/min and UV detection at 210, 230, and 280 nm. RESULTS: The method was validated for linearity, precision, and accuracy. All calibration curves showed good linear regression (r(2) > 0.9996). Limits of detection (LOD) and limits of quantification (LOQ) fell in the ranges 0.01 - 0.28 μg/ml and 0.04 - 0.83 μg/ml, respectively. The relative standard deviation (RSD) of the intra- and inter- day test, precision test were within 1.92% and 2.43%, respectively. The mean recovery of all ranged from 92.82 to 107.96% with RSD values 0.12 - 2.18%. CONCLUSION: The results of validation appeared that this established method was very accurate and stabilized for the quantification of 10 bioactive compounds isolated from C. paniculatum. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3466459/ /pubmed/23060698 http://dx.doi.org/10.4103/0973-1296.99289 Text en Copyright: © Pharmacognosy Magazine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Weon, Jin Bae
Lee, Bohyoung
Yun, Bo-Ra
Lee, Jiwoo
Ma, Choong Je
Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title_full Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title_fullStr Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title_full_unstemmed Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title_short Simultaneous determination of ten bioactive compaounds from the roots of Cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
title_sort simultaneous determination of ten bioactive compaounds from the roots of cynanchum paniculatum by using high performance liquid chromatography coupled-diode array detector
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466459/
https://www.ncbi.nlm.nih.gov/pubmed/23060698
http://dx.doi.org/10.4103/0973-1296.99289
work_keys_str_mv AT weonjinbae simultaneousdeterminationoftenbioactivecompaoundsfromtherootsofcynanchumpaniculatumbyusinghighperformanceliquidchromatographycoupleddiodearraydetector
AT leebohyoung simultaneousdeterminationoftenbioactivecompaoundsfromtherootsofcynanchumpaniculatumbyusinghighperformanceliquidchromatographycoupleddiodearraydetector
AT yunbora simultaneousdeterminationoftenbioactivecompaoundsfromtherootsofcynanchumpaniculatumbyusinghighperformanceliquidchromatographycoupleddiodearraydetector
AT leejiwoo simultaneousdeterminationoftenbioactivecompaoundsfromtherootsofcynanchumpaniculatumbyusinghighperformanceliquidchromatographycoupleddiodearraydetector
AT machoongje simultaneousdeterminationoftenbioactivecompaoundsfromtherootsofcynanchumpaniculatumbyusinghighperformanceliquidchromatographycoupleddiodearraydetector