Cargando…

The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study

OBJECTIVE: Calcium hydroxide is the most widely used intracanal medicament in endodontics, which should be removed prior to permanent root canal filling to minimize its intervention with the bonding of endodontic sealers. This ex-vivo study aimed to evaluate the effect of pretreatment with calcium h...

Descripción completa

Detalles Bibliográficos
Autores principales: Bolhari, B., Shokouhinejad, N., Masoudi, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466769/
https://www.ncbi.nlm.nih.gov/pubmed/23066480
_version_ 1782245703513276416
author Bolhari, B.
Shokouhinejad, N.
Masoudi, A.
author_facet Bolhari, B.
Shokouhinejad, N.
Masoudi, A.
author_sort Bolhari, B.
collection PubMed
description OBJECTIVE: Calcium hydroxide is the most widely used intracanal medicament in endodontics, which should be removed prior to permanent root canal filling to minimize its intervention with the bonding of endodontic sealers. This ex-vivo study aimed to evaluate the effect of pretreatment with calcium hydroxide on the bond strength of Resilon/Epiphany self etch (SE) to the radicular dentin after removing the calcium hydroxide by hand file or ultrasonic methods. MATERIALS AND METHODS: Thirty-six single-rooted human extracted teeth were used in this study. After root canal preparation, the teeth were divided into three groups. In group 1, as the control, no pretreatment was performed; while in groups 2 and 3, this was carried out using calcium hydroxide paste. After one week, the paste was removed with hand stainless steel K-files in group 2 and ultrasonic instrumentation in group 3. All samples were obturated with Resilon/Epiphany SE. One-millimeter slices of mid-root dentin were prepared for the push-out test (14 slices per group). After the bond strength was assessed, the failure modes were examined. The data were analyzed using one-way ANOVA and Dunnett Post Hoc tests. RESULTS: Group 2 significantly showed the lowest bond strength (0.947 ± 0.47) (P = 0.01). No significant differences were found between the control group (2.32 ± 1.43) and group 3 (1.78 ± 1.04) (P = 0.01). CONCLUSIONS: Under the conditions of this ex vivo study, calcium hydroxide as the intracanal medicament and its removal using hand instrumentation adversely affected the bond strength of Resilon/Epiphany SE.
format Online
Article
Text
id pubmed-3466769
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-34667692012-10-12 The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study Bolhari, B. Shokouhinejad, N. Masoudi, A. J Dent (Tehran) Original Article OBJECTIVE: Calcium hydroxide is the most widely used intracanal medicament in endodontics, which should be removed prior to permanent root canal filling to minimize its intervention with the bonding of endodontic sealers. This ex-vivo study aimed to evaluate the effect of pretreatment with calcium hydroxide on the bond strength of Resilon/Epiphany self etch (SE) to the radicular dentin after removing the calcium hydroxide by hand file or ultrasonic methods. MATERIALS AND METHODS: Thirty-six single-rooted human extracted teeth were used in this study. After root canal preparation, the teeth were divided into three groups. In group 1, as the control, no pretreatment was performed; while in groups 2 and 3, this was carried out using calcium hydroxide paste. After one week, the paste was removed with hand stainless steel K-files in group 2 and ultrasonic instrumentation in group 3. All samples were obturated with Resilon/Epiphany SE. One-millimeter slices of mid-root dentin were prepared for the push-out test (14 slices per group). After the bond strength was assessed, the failure modes were examined. The data were analyzed using one-way ANOVA and Dunnett Post Hoc tests. RESULTS: Group 2 significantly showed the lowest bond strength (0.947 ± 0.47) (P = 0.01). No significant differences were found between the control group (2.32 ± 1.43) and group 3 (1.78 ± 1.04) (P = 0.01). CONCLUSIONS: Under the conditions of this ex vivo study, calcium hydroxide as the intracanal medicament and its removal using hand instrumentation adversely affected the bond strength of Resilon/Epiphany SE. Tehran University of Medical Sciences 2012 2012-06-30 /pmc/articles/PMC3466769/ /pubmed/23066480 Text en Copyright © Dental Research Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Bolhari, B.
Shokouhinejad, N.
Masoudi, A.
The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title_full The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title_fullStr The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title_full_unstemmed The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title_short The Effect of Calcium Hydroxide on the Bond Strength of Resilon/Epiphany Self-Etch and Assessment of Calcium Hydroxide Removal Techniques: An Ex-Vivo Study
title_sort effect of calcium hydroxide on the bond strength of resilon/epiphany self-etch and assessment of calcium hydroxide removal techniques: an ex-vivo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466769/
https://www.ncbi.nlm.nih.gov/pubmed/23066480
work_keys_str_mv AT bolharib theeffectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy
AT shokouhinejadn theeffectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy
AT masoudia theeffectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy
AT bolharib effectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy
AT shokouhinejadn effectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy
AT masoudia effectofcalciumhydroxideonthebondstrengthofresilonepiphanyselfetchandassessmentofcalciumhydroxideremovaltechniquesanexvivostudy