Cargando…

Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method

BACKGROUND: Transcatheter closure of atrial septal defect secundum (ASD-II) has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE) method for measuring atrial septal defect with balloon occlusive diameter (BOD) in transcatheter A...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadeghian, Hakimeh, Hajizeinali, Alimohammad, Eslami, Bahareh, Lotfi-Tokaldany, Masoumeh, Sheikhfathollahi, Mahmood, Sahebjam, Mohammad, Hakki, Elham, Zoroufian, Arezou, Kassaian, Seyed Ebrahim, Alidoosti, Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466821/
https://www.ncbi.nlm.nih.gov/pubmed/23074571
_version_ 1782245707101503488
author Sadeghian, Hakimeh
Hajizeinali, Alimohammad
Eslami, Bahareh
Lotfi-Tokaldany, Masoumeh
Sheikhfathollahi, Mahmood
Sahebjam, Mohammad
Hakki, Elham
Zoroufian, Arezou
Kassaian, Seyed Ebrahim
Alidoosti, Mohammad
author_facet Sadeghian, Hakimeh
Hajizeinali, Alimohammad
Eslami, Bahareh
Lotfi-Tokaldany, Masoumeh
Sheikhfathollahi, Mahmood
Sahebjam, Mohammad
Hakki, Elham
Zoroufian, Arezou
Kassaian, Seyed Ebrahim
Alidoosti, Mohammad
author_sort Sadeghian, Hakimeh
collection PubMed
description BACKGROUND: Transcatheter closure of atrial septal defect secundum (ASD-II) has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE) method for measuring atrial septal defect with balloon occlusive diameter (BOD) in transcatheter ASD-II closure. METHODS: A total of 39 patients (71.1% female, mean age: 35.31 ± 15.37 years) who underwent successful transcatheter closure of ASD-II between November 2005 and July 2008 were enrolled in this study. Transthoracic echocardiography (TTE) and TEE were performed to select suitable cases for device closure and measure the defect size before the procedure, and BOD measurement was performed during catheterization via TEE. The final size of the selected device was usually either equal to or 1 – 2 mm larger than the BOD of the defect. RESULTS: The mean defect size obtained by TEE and BOD was 18.50 ± 5.08 mm and 22.86 ± 4.76 mm, respectively. The mean difference between the values of ASD size obtained by TEE and BOD was 4.36 ± 2.93 mm. In comparison with BOD, TEE underestimated the defect size in 94.9%, but TEE value being equal to BOD was observed in 5.1%. There was a good linear correlation between the two measurements: BOD = 0.773 × ASD size by TEE+8.562; r2 = 67.9.1%. A negative correlation was found between TEE sizing and the difference between BOD and TEE values (r = −0.394, p value = 0.013). CONCLUSION: In this study, BOD was larger than ASD size obtained by two-dimensional TEE. However, TEE maximal defect sizing correlates with BOD and may provide credible information in device size selection for transcatheter ASD closure.
format Online
Article
Text
id pubmed-3466821
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-34668212012-10-16 Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method Sadeghian, Hakimeh Hajizeinali, Alimohammad Eslami, Bahareh Lotfi-Tokaldany, Masoumeh Sheikhfathollahi, Mahmood Sahebjam, Mohammad Hakki, Elham Zoroufian, Arezou Kassaian, Seyed Ebrahim Alidoosti, Mohammad J Tehran Heart Cent Original Article BACKGROUND: Transcatheter closure of atrial septal defect secundum (ASD-II) has become an alternative method for surgery. We sought to compare the two-dimensional transesophageal echocardiography (TEE) method for measuring atrial septal defect with balloon occlusive diameter (BOD) in transcatheter ASD-II closure. METHODS: A total of 39 patients (71.1% female, mean age: 35.31 ± 15.37 years) who underwent successful transcatheter closure of ASD-II between November 2005 and July 2008 were enrolled in this study. Transthoracic echocardiography (TTE) and TEE were performed to select suitable cases for device closure and measure the defect size before the procedure, and BOD measurement was performed during catheterization via TEE. The final size of the selected device was usually either equal to or 1 – 2 mm larger than the BOD of the defect. RESULTS: The mean defect size obtained by TEE and BOD was 18.50 ± 5.08 mm and 22.86 ± 4.76 mm, respectively. The mean difference between the values of ASD size obtained by TEE and BOD was 4.36 ± 2.93 mm. In comparison with BOD, TEE underestimated the defect size in 94.9%, but TEE value being equal to BOD was observed in 5.1%. There was a good linear correlation between the two measurements: BOD = 0.773 × ASD size by TEE+8.562; r2 = 67.9.1%. A negative correlation was found between TEE sizing and the difference between BOD and TEE values (r = −0.394, p value = 0.013). CONCLUSION: In this study, BOD was larger than ASD size obtained by two-dimensional TEE. However, TEE maximal defect sizing correlates with BOD and may provide credible information in device size selection for transcatheter ASD closure. Tehran University of Medical Sciences 2010 2010-05-31 /pmc/articles/PMC3466821/ /pubmed/23074571 Text en Copyright © Tehran Heart Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Sadeghian, Hakimeh
Hajizeinali, Alimohammad
Eslami, Bahareh
Lotfi-Tokaldany, Masoumeh
Sheikhfathollahi, Mahmood
Sahebjam, Mohammad
Hakki, Elham
Zoroufian, Arezou
Kassaian, Seyed Ebrahim
Alidoosti, Mohammad
Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title_full Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title_fullStr Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title_full_unstemmed Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title_short Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method
title_sort measurement of atrial septal defect size: a comparative study between transesophageal echocardiography and balloon occlusive diameter method
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466821/
https://www.ncbi.nlm.nih.gov/pubmed/23074571
work_keys_str_mv AT sadeghianhakimeh measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT hajizeinalialimohammad measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT eslamibahareh measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT lotfitokaldanymasoumeh measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT sheikhfathollahimahmood measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT sahebjammohammad measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT hakkielham measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT zoroufianarezou measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT kassaianseyedebrahim measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod
AT alidoostimohammad measurementofatrialseptaldefectsizeacomparativestudybetweentransesophagealechocardiographyandballoonocclusivediametermethod