Cargando…

Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia

BACKGROUND: Nowadays, developed junctional rhythm (JR) that occurs during slow-pathway radiofrequency (RF) catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) has been focused upon as a highly sensitive surrogate end point for successful radiofrequency ablation. This study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Bagherzadeh, Ataallah, Rezaee, Mohammad Esmaeel, Farahani, Maryam Moshkani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466865/
https://www.ncbi.nlm.nih.gov/pubmed/23074599
_version_ 1782245717346091008
author Bagherzadeh, Ataallah
Rezaee, Mohammad Esmaeel
Farahani, Maryam Moshkani
author_facet Bagherzadeh, Ataallah
Rezaee, Mohammad Esmaeel
Farahani, Maryam Moshkani
author_sort Bagherzadeh, Ataallah
collection PubMed
description BACKGROUND: Nowadays, developed junctional rhythm (JR) that occurs during slow-pathway radiofrequency (RF) catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) has been focused upon as a highly sensitive surrogate end point for successful radiofrequency ablation. This study was conducted to assess the relationship between the presence and pattern of developed JR during the RF ablation of AVNRT and a successful outcome. METHODS: Seventy-five patients aged between 14 and 88 who underwent slow-pathway RF ablation due to symptomatic AVNRT were enrolled into the study and received a total of 162 RF energy applications. Combined anatomic and electrogram mapping approach was used for slow-pathway RF ablation. The ablation procedure consisted of 60-second, 60 °C temperature-controlled energy delivery. After each ablation pulse, successful ablation was assessed according to the loss of AVNRT inducibility via isoproterenol infusion. Four different patterns were considered for the developed JR, namely sparse, intermittent, continuous, and transient block. Success ablation rate was assessed with respect to the position, pattern, and number of junctional beats. RESULTS: Successful RF ablation with a loss of AVNRT inducibility was achieved in 43 (57.3%) patients using 119 RF energy applications (73.5%). JR developed in 133 of the 162 (82.1%) applications with a given sensitivity of 90.8% and low specificity of 41.9% as an end point of successful RF ablation, with a negative predictive value of 62.1%. The mean number of the developed junctional beats was significantly higher in the successful ablations (p value < 0.001), and the ROC analysis revealed that the best cut-off point of the cumulative junctional beats for identifying accurate AVNRT ablation therapy is 14 beats with 90.76 % sensitivity and 90.70% specificity. There were no significant differences in terms of successful ablation rates according to the four different patterns of JR and its positions (p value=0.338, p value=0.105, respectively) in the univariate analyses. CONCLUSION: JR is a sensitive but non-specific predictor of the successful RF ablation of AVNRT. Nevertheless, according to the results, its specificity could increase with the presence of more than 14 cumulative junctional beats. Although the development of JR during slow-pathway RF ablation seems not to be reliable as a success end point, its absences could be a marker of requiring more energy application to ablate the slow pathway.
format Online
Article
Text
id pubmed-3466865
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-34668652012-10-16 Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia Bagherzadeh, Ataallah Rezaee, Mohammad Esmaeel Farahani, Maryam Moshkani J Tehran Heart Cent Original Article BACKGROUND: Nowadays, developed junctional rhythm (JR) that occurs during slow-pathway radiofrequency (RF) catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) has been focused upon as a highly sensitive surrogate end point for successful radiofrequency ablation. This study was conducted to assess the relationship between the presence and pattern of developed JR during the RF ablation of AVNRT and a successful outcome. METHODS: Seventy-five patients aged between 14 and 88 who underwent slow-pathway RF ablation due to symptomatic AVNRT were enrolled into the study and received a total of 162 RF energy applications. Combined anatomic and electrogram mapping approach was used for slow-pathway RF ablation. The ablation procedure consisted of 60-second, 60 °C temperature-controlled energy delivery. After each ablation pulse, successful ablation was assessed according to the loss of AVNRT inducibility via isoproterenol infusion. Four different patterns were considered for the developed JR, namely sparse, intermittent, continuous, and transient block. Success ablation rate was assessed with respect to the position, pattern, and number of junctional beats. RESULTS: Successful RF ablation with a loss of AVNRT inducibility was achieved in 43 (57.3%) patients using 119 RF energy applications (73.5%). JR developed in 133 of the 162 (82.1%) applications with a given sensitivity of 90.8% and low specificity of 41.9% as an end point of successful RF ablation, with a negative predictive value of 62.1%. The mean number of the developed junctional beats was significantly higher in the successful ablations (p value < 0.001), and the ROC analysis revealed that the best cut-off point of the cumulative junctional beats for identifying accurate AVNRT ablation therapy is 14 beats with 90.76 % sensitivity and 90.70% specificity. There were no significant differences in terms of successful ablation rates according to the four different patterns of JR and its positions (p value=0.338, p value=0.105, respectively) in the univariate analyses. CONCLUSION: JR is a sensitive but non-specific predictor of the successful RF ablation of AVNRT. Nevertheless, according to the results, its specificity could increase with the presence of more than 14 cumulative junctional beats. Although the development of JR during slow-pathway RF ablation seems not to be reliable as a success end point, its absences could be a marker of requiring more energy application to ablate the slow pathway. Tehran University of Medical Sciences 2011 2011-02-28 /pmc/articles/PMC3466865/ /pubmed/23074599 Text en Copyright © Tehran Heart Center, Tehran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Bagherzadeh, Ataallah
Rezaee, Mohammad Esmaeel
Farahani, Maryam Moshkani
Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title_full Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title_fullStr Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title_full_unstemmed Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title_short Prediction of Primary Slow-Pathway Ablation Success Rate according to the Characteristics of Junctional Rhythm Developed during the Radiofrequency Catheter Ablation of Atrioventricular Nodal Reentrant Tachycardia
title_sort prediction of primary slow-pathway ablation success rate according to the characteristics of junctional rhythm developed during the radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3466865/
https://www.ncbi.nlm.nih.gov/pubmed/23074599
work_keys_str_mv AT bagherzadehataallah predictionofprimaryslowpathwayablationsuccessrateaccordingtothecharacteristicsofjunctionalrhythmdevelopedduringtheradiofrequencycatheterablationofatrioventricularnodalreentranttachycardia
AT rezaeemohammadesmaeel predictionofprimaryslowpathwayablationsuccessrateaccordingtothecharacteristicsofjunctionalrhythmdevelopedduringtheradiofrequencycatheterablationofatrioventricularnodalreentranttachycardia
AT farahanimaryammoshkani predictionofprimaryslowpathwayablationsuccessrateaccordingtothecharacteristicsofjunctionalrhythmdevelopedduringtheradiofrequencycatheterablationofatrioventricularnodalreentranttachycardia