Cargando…
Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale
BACKGROUND AND PURPOSE: The National Institutes of Health Stroke Scale (NIHSS) is a clinical assessment tool that is widely used in clinical trials and practice to evaluate stroke-related neurological deficits. The aim of this study was to determine the validity and reliability of the Korean version...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Neurological Association
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469797/ https://www.ncbi.nlm.nih.gov/pubmed/23091526 http://dx.doi.org/10.3988/jcn.2012.8.3.177 |
_version_ | 1782246128500080640 |
---|---|
author | Oh, Mi Sun Yu, Kyung-Ho Lee, Ju-Hun Jung, San Ko, Im-Suck Shin, Joon-Hyun Cho, Soo-Jin Choi, Hui-Chul Kim, Hyang Hee Lee, Byung-Chul |
author_facet | Oh, Mi Sun Yu, Kyung-Ho Lee, Ju-Hun Jung, San Ko, Im-Suck Shin, Joon-Hyun Cho, Soo-Jin Choi, Hui-Chul Kim, Hyang Hee Lee, Byung-Chul |
author_sort | Oh, Mi Sun |
collection | PubMed |
description | BACKGROUND AND PURPOSE: The National Institutes of Health Stroke Scale (NIHSS) is a clinical assessment tool that is widely used in clinical trials and practice to evaluate stroke-related neurological deficits. The aim of this study was to determine the validity and reliability of the Korean version of the NIHSS (K-NIHSS) for evaluating Korean stroke patients. METHODS: The K-NIHSS was translated and adapted with regard to cultural and linguistic peculiarities. To examine its content validity, we quantified the Content Validity Index (CVI), which was rated by 11 stroke experts. The validity of the K-NIHSS was assessed by comparison with the Glasgow Coma Scale (GCS), the modified Rankin Scale (mRS), and the Barthel Index. The reliability of the K-NIHSS was evaluated using the unweighted kappa statistics for multiple raters and an intraclass correlation coefficient (ICC). RESULTS: The CVI of the K-NIHSS reached 0.91-1.00. The median K-NIHSS score at baseline was 3 (interquartile range, 2-7), and the mean±SD score was 6.0±6.6. The baseline K-NIHSS had a significantly negative correlation with the GCS at baseline and the Barthel Index after 90 days. The K-NIHSS also had a significantly positive correlation with the mRS after 90 days. Facial paresis and dysarthria had moderate interrater reliability (unweighted kappa, 0.41-0.60); kappa values were substantial to excellent (unweighted kappa, >0.60) for all the other items. The ICC for the overall K-NIHSS score was 0.998. The intrarater reliability was acceptable, with a median kappa range of 0.524-1.000. CONCLUSIONS: The K-NIHSS is a valid and reliable tool for assessing neurological deficits in Korean acute stroke patients. |
format | Online Article Text |
id | pubmed-3469797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Korean Neurological Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-34697972012-10-22 Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale Oh, Mi Sun Yu, Kyung-Ho Lee, Ju-Hun Jung, San Ko, Im-Suck Shin, Joon-Hyun Cho, Soo-Jin Choi, Hui-Chul Kim, Hyang Hee Lee, Byung-Chul J Clin Neurol Original Article BACKGROUND AND PURPOSE: The National Institutes of Health Stroke Scale (NIHSS) is a clinical assessment tool that is widely used in clinical trials and practice to evaluate stroke-related neurological deficits. The aim of this study was to determine the validity and reliability of the Korean version of the NIHSS (K-NIHSS) for evaluating Korean stroke patients. METHODS: The K-NIHSS was translated and adapted with regard to cultural and linguistic peculiarities. To examine its content validity, we quantified the Content Validity Index (CVI), which was rated by 11 stroke experts. The validity of the K-NIHSS was assessed by comparison with the Glasgow Coma Scale (GCS), the modified Rankin Scale (mRS), and the Barthel Index. The reliability of the K-NIHSS was evaluated using the unweighted kappa statistics for multiple raters and an intraclass correlation coefficient (ICC). RESULTS: The CVI of the K-NIHSS reached 0.91-1.00. The median K-NIHSS score at baseline was 3 (interquartile range, 2-7), and the mean±SD score was 6.0±6.6. The baseline K-NIHSS had a significantly negative correlation with the GCS at baseline and the Barthel Index after 90 days. The K-NIHSS also had a significantly positive correlation with the mRS after 90 days. Facial paresis and dysarthria had moderate interrater reliability (unweighted kappa, 0.41-0.60); kappa values were substantial to excellent (unweighted kappa, >0.60) for all the other items. The ICC for the overall K-NIHSS score was 0.998. The intrarater reliability was acceptable, with a median kappa range of 0.524-1.000. CONCLUSIONS: The K-NIHSS is a valid and reliable tool for assessing neurological deficits in Korean acute stroke patients. Korean Neurological Association 2012-09 2012-09-27 /pmc/articles/PMC3469797/ /pubmed/23091526 http://dx.doi.org/10.3988/jcn.2012.8.3.177 Text en Copyright © 2012 Korean Neurological Association http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Oh, Mi Sun Yu, Kyung-Ho Lee, Ju-Hun Jung, San Ko, Im-Suck Shin, Joon-Hyun Cho, Soo-Jin Choi, Hui-Chul Kim, Hyang Hee Lee, Byung-Chul Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title | Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title_full | Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title_fullStr | Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title_full_unstemmed | Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title_short | Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale |
title_sort | validity and reliability of a korean version of the national institutes of health stroke scale |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469797/ https://www.ncbi.nlm.nih.gov/pubmed/23091526 http://dx.doi.org/10.3988/jcn.2012.8.3.177 |
work_keys_str_mv | AT ohmisun validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT yukyungho validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT leejuhun validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT jungsan validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT koimsuck validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT shinjoonhyun validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT chosoojin validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT choihuichul validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT kimhyanghee validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale AT leebyungchul validityandreliabilityofakoreanversionofthenationalinstitutesofhealthstrokescale |