Cargando…

Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching

BACKGROUND: Based on contradictory findings concerning the use of lasers for enamel etching, the purpose of this study was to investigate the shear bond strength of teeth prepared for bonding with Er-YAG laser etching and compare them with phosphoric acid etching. MATERIALS AND METHODS: In this in v...

Descripción completa

Detalles Bibliográficos
Autores principales: Raji, S. Hamid, Birang, Reza, Majdzade, Fateme, Ghorbanipour, Reza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469894/
https://www.ncbi.nlm.nih.gov/pubmed/23087733
_version_ 1782246151013007360
author Raji, S. Hamid
Birang, Reza
Majdzade, Fateme
Ghorbanipour, Reza
author_facet Raji, S. Hamid
Birang, Reza
Majdzade, Fateme
Ghorbanipour, Reza
author_sort Raji, S. Hamid
collection PubMed
description BACKGROUND: Based on contradictory findings concerning the use of lasers for enamel etching, the purpose of this study was to investigate the shear bond strength of teeth prepared for bonding with Er-YAG laser etching and compare them with phosphoric acid etching. MATERIALS AND METHODS: In this in vitro study forty – eight premolars, extracted for orthodontic purposes were randomly divided in to three groups. Thirty-two teeth were exposed to laser energy for 25 s: 16 teeth at 100 mj setting and 16 teeth at 150 mj setting. Sixteen teeth were etched with 37% phosphoric acid. The shear bond strength of bonded brackets with the Transbond XT adhesive system was measured with the Zwick testing machine. Descriptive statistics, Kolmogorov–Smirnov test, of homogeneity of variances, one- way analysis of variances and Tukey's test and Kruskal Wallis were used to analyze the data. RESULTS: The mean shear bond strength of the teeth lased with 150 mj was 12.26 ± 4.76 MPa, which was not significantly different from the group with acid etching (15.26 ± 4.16 MPa). Irradiation with 100 mj resulted in mean bond strengths of 9.05 ± 3.16 MPa, which was significantly different from that of acid etching (P < 0.001). CONCLUSIONS: laser etching at 150 and 100 mj was adequate for bond strength but the failure pattern of brackets bonded with laser etching is dominantly at adhesive – enamel interface and is not safe for enamel during debonding.
format Online
Article
Text
id pubmed-3469894
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-34698942012-10-19 Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching Raji, S. Hamid Birang, Reza Majdzade, Fateme Ghorbanipour, Reza Dent Res J (Isfahan) Original Article BACKGROUND: Based on contradictory findings concerning the use of lasers for enamel etching, the purpose of this study was to investigate the shear bond strength of teeth prepared for bonding with Er-YAG laser etching and compare them with phosphoric acid etching. MATERIALS AND METHODS: In this in vitro study forty – eight premolars, extracted for orthodontic purposes were randomly divided in to three groups. Thirty-two teeth were exposed to laser energy for 25 s: 16 teeth at 100 mj setting and 16 teeth at 150 mj setting. Sixteen teeth were etched with 37% phosphoric acid. The shear bond strength of bonded brackets with the Transbond XT adhesive system was measured with the Zwick testing machine. Descriptive statistics, Kolmogorov–Smirnov test, of homogeneity of variances, one- way analysis of variances and Tukey's test and Kruskal Wallis were used to analyze the data. RESULTS: The mean shear bond strength of the teeth lased with 150 mj was 12.26 ± 4.76 MPa, which was not significantly different from the group with acid etching (15.26 ± 4.16 MPa). Irradiation with 100 mj resulted in mean bond strengths of 9.05 ± 3.16 MPa, which was significantly different from that of acid etching (P < 0.001). CONCLUSIONS: laser etching at 150 and 100 mj was adequate for bond strength but the failure pattern of brackets bonded with laser etching is dominantly at adhesive – enamel interface and is not safe for enamel during debonding. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3469894/ /pubmed/23087733 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Raji, S. Hamid
Birang, Reza
Majdzade, Fateme
Ghorbanipour, Reza
Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title_full Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title_fullStr Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title_full_unstemmed Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title_short Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching
title_sort evaluation of shear bond strength of orthodontic brackets bonded with er-yag laser etching
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469894/
https://www.ncbi.nlm.nih.gov/pubmed/23087733
work_keys_str_mv AT rajishamid evaluationofshearbondstrengthoforthodonticbracketsbondedwitheryaglaseretching
AT birangreza evaluationofshearbondstrengthoforthodonticbracketsbondedwitheryaglaseretching
AT majdzadefateme evaluationofshearbondstrengthoforthodonticbracketsbondedwitheryaglaseretching
AT ghorbanipourreza evaluationofshearbondstrengthoforthodonticbracketsbondedwitheryaglaseretching