Cargando…

Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients

PURPOSE: The objective of the study was to compare the performance of i-gel supraglottic airway with cLMA in difficult airway management in post burn neck contracture patients and assess the feasibility of i-gel use for emergency airway management in difficult airway situation with reduced neck move...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Jeevan, Yadav, Manohar Kumar, Marahatta, Sujan Babu, Shrestha, Bikash Lal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469912/
https://www.ncbi.nlm.nih.gov/pubmed/23087456
http://dx.doi.org/10.4103/0019-5049.100815
_version_ 1782246155199971328
author Singh, Jeevan
Yadav, Manohar Kumar
Marahatta, Sujan Babu
Shrestha, Bikash Lal
author_facet Singh, Jeevan
Yadav, Manohar Kumar
Marahatta, Sujan Babu
Shrestha, Bikash Lal
author_sort Singh, Jeevan
collection PubMed
description PURPOSE: The objective of the study was to compare the performance of i-gel supraglottic airway with cLMA in difficult airway management in post burn neck contracture patients and assess the feasibility of i-gel use for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening. METHODS: Prospective, crossover, randomized controlled trial was performed amongst forty eight post burn neck contracture patients with limited mouth opening and neck movement. i-gel and cLMA were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, visualization of square wave pattern. RESULTS: Success rate for the i-gel was 91.7% versus 79.2% for the cLMA. i-gel required shorter insertion time (19.3 seconds vs. 23.5 seconds, P=0.000). Airway leak pressure difference was statistically significant (i-gel 21.2 cm H20; cLMA 16.9 cm H(2)0; P=0.00). Fiberoptic view through the i-gel showed there were less epiglottic downfolding and better fiberoptic view of the glottis than cLMA. Overall agreement in insertion outcome for i-gel was 22/24 (91.7%) successes and 2/24(8.3%) failure and for cLMA, 19/24 (79.16%) successes and 5/24 (16.7%) failure in the first attempt. CONCLUSION: The i-gel is cheap, effective airway device which is easier to insert and has better clinical performance in the difficult airway management of the airway in the post burn contracture of the neck. Our study shows that i-gel is feasible for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening in post burn neck.
format Online
Article
Text
id pubmed-3469912
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-34699122012-10-19 Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients Singh, Jeevan Yadav, Manohar Kumar Marahatta, Sujan Babu Shrestha, Bikash Lal Indian J Anaesth Clinical Investigation PURPOSE: The objective of the study was to compare the performance of i-gel supraglottic airway with cLMA in difficult airway management in post burn neck contracture patients and assess the feasibility of i-gel use for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening. METHODS: Prospective, crossover, randomized controlled trial was performed amongst forty eight post burn neck contracture patients with limited mouth opening and neck movement. i-gel and cLMA were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, visualization of square wave pattern. RESULTS: Success rate for the i-gel was 91.7% versus 79.2% for the cLMA. i-gel required shorter insertion time (19.3 seconds vs. 23.5 seconds, P=0.000). Airway leak pressure difference was statistically significant (i-gel 21.2 cm H20; cLMA 16.9 cm H(2)0; P=0.00). Fiberoptic view through the i-gel showed there were less epiglottic downfolding and better fiberoptic view of the glottis than cLMA. Overall agreement in insertion outcome for i-gel was 22/24 (91.7%) successes and 2/24(8.3%) failure and for cLMA, 19/24 (79.16%) successes and 5/24 (16.7%) failure in the first attempt. CONCLUSION: The i-gel is cheap, effective airway device which is easier to insert and has better clinical performance in the difficult airway management of the airway in the post burn contracture of the neck. Our study shows that i-gel is feasible for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening in post burn neck. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3469912/ /pubmed/23087456 http://dx.doi.org/10.4103/0019-5049.100815 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Investigation
Singh, Jeevan
Yadav, Manohar Kumar
Marahatta, Sujan Babu
Shrestha, Bikash Lal
Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title_full Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title_fullStr Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title_full_unstemmed Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title_short Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
title_sort randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469912/
https://www.ncbi.nlm.nih.gov/pubmed/23087456
http://dx.doi.org/10.4103/0019-5049.100815
work_keys_str_mv AT singhjeevan randomizedcrossovercomparisonofthelaryngealmaskairwayclassicwithigellaryngealmaskairwayinthemanagementofdifficultairwayinpostburnneckcontracturepatients
AT yadavmanoharkumar randomizedcrossovercomparisonofthelaryngealmaskairwayclassicwithigellaryngealmaskairwayinthemanagementofdifficultairwayinpostburnneckcontracturepatients
AT marahattasujanbabu randomizedcrossovercomparisonofthelaryngealmaskairwayclassicwithigellaryngealmaskairwayinthemanagementofdifficultairwayinpostburnneckcontracturepatients
AT shresthabikashlal randomizedcrossovercomparisonofthelaryngealmaskairwayclassicwithigellaryngealmaskairwayinthemanagementofdifficultairwayinpostburnneckcontracturepatients