Cargando…
Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model
Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA) stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Bio...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3470892/ https://www.ncbi.nlm.nih.gov/pubmed/23093843 http://dx.doi.org/10.1155/2012/413956 |
_version_ | 1782246325373370368 |
---|---|
author | Wu, Yizhe Shen, Li Wang, Qibing Ge, Lei Xie, Jian Hu, Xi Sun, Aijun Qian, Juying Ge, Junbo |
author_facet | Wu, Yizhe Shen, Li Wang, Qibing Ge, Lei Xie, Jian Hu, Xi Sun, Aijun Qian, Juying Ge, Junbo |
author_sort | Wu, Yizhe |
collection | PubMed |
description | Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA) stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China) and eight metallic stents (EXCEL, Jiwei Co., Ltd. China) were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X) and mean lumen diameter of stent immediately after deployment (Y), while acute percent recoil was defined as (X−Y)/X and expressed as a percentage. Intravascular ultrasound (IVUS) was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA) between two groups and detect stent malapposition or collapse. Results. Acute absolute recoil in XINSORB and EXCEL was 0.02 ± 0.13 mm and −0.08 ± 0.08 mm respectively (P = 0.19). Acute percent recoil in XINSORB and EXCEL was 0.66 ± 4.32% and −1.40 ± 3.83%, respectively (P = 0.45). CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. Conclusions. The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent. |
format | Online Article Text |
id | pubmed-3470892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-34708922012-10-23 Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model Wu, Yizhe Shen, Li Wang, Qibing Ge, Lei Xie, Jian Hu, Xi Sun, Aijun Qian, Juying Ge, Junbo J Biomed Biotechnol Research Article Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA) stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China) and eight metallic stents (EXCEL, Jiwei Co., Ltd. China) were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X) and mean lumen diameter of stent immediately after deployment (Y), while acute percent recoil was defined as (X−Y)/X and expressed as a percentage. Intravascular ultrasound (IVUS) was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA) between two groups and detect stent malapposition or collapse. Results. Acute absolute recoil in XINSORB and EXCEL was 0.02 ± 0.13 mm and −0.08 ± 0.08 mm respectively (P = 0.19). Acute percent recoil in XINSORB and EXCEL was 0.66 ± 4.32% and −1.40 ± 3.83%, respectively (P = 0.45). CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. Conclusions. The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent. Hindawi Publishing Corporation 2012 2012-10-03 /pmc/articles/PMC3470892/ /pubmed/23093843 http://dx.doi.org/10.1155/2012/413956 Text en Copyright © 2012 Yizhe Wu et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Wu, Yizhe Shen, Li Wang, Qibing Ge, Lei Xie, Jian Hu, Xi Sun, Aijun Qian, Juying Ge, Junbo Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title | Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title_full | Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title_fullStr | Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title_full_unstemmed | Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title_short | Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model |
title_sort | comparison of acute recoil between bioabsorbable poly-l-lactic acid xinsorb stent and metallic stent in porcine model |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3470892/ https://www.ncbi.nlm.nih.gov/pubmed/23093843 http://dx.doi.org/10.1155/2012/413956 |
work_keys_str_mv | AT wuyizhe comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT shenli comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT wangqibing comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT gelei comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT xiejian comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT huxi comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT sunaijun comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT qianjuying comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel AT gejunbo comparisonofacuterecoilbetweenbioabsorbablepolyllacticacidxinsorbstentandmetallicstentinporcinemodel |