Cargando…

Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging

The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view o...

Descripción completa

Detalles Bibliográficos
Autores principales: Fortune, Steven, Jansen, Maurits A., Anderson, Tom, Gray, Gillian A., Schneider, Jürgen E., Hoskins, Peter R., Marshall, Ian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471072/
https://www.ncbi.nlm.nih.gov/pubmed/22770689
http://dx.doi.org/10.1016/j.mri.2012.04.008
_version_ 1782246370244034560
author Fortune, Steven
Jansen, Maurits A.
Anderson, Tom
Gray, Gillian A.
Schneider, Jürgen E.
Hoskins, Peter R.
Marshall, Ian
author_facet Fortune, Steven
Jansen, Maurits A.
Anderson, Tom
Gray, Gillian A.
Schneider, Jürgen E.
Hoskins, Peter R.
Marshall, Ian
author_sort Fortune, Steven
collection PubMed
description The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view of left ventricular motion of rats and mice, thus reducing the need for live animals in the development of MRI. Cylindrical phantoms were moulded from polyvinyl alcohol (PVA) Cryogel and attached via stiff water-filled tubing to a gear pump. Pulsatile distension of the phantoms was effected by suitable programming of the pump. Cine MRI scanning was carried out at 7 T and compared with in vivo rodent cardiac imaging. Suitable pulsatile performance was achieved with phantoms for which the PVA material had been subjected to two freeze–thaw cycles, resulting in T1 and T2 relaxation time constants of 1656±124 ms and 55±10 ms, respectively. For the rat phantom operating at 240 beats per min (bpm), the dynamic range of the outer diameter was from 10.3 to 12.4 mm with the wall thickness varying between 1.9 and 1.2 mm. Corresponding figures for the mouse phantom at 480 bpm were outer diameter range from 5.4 to 6.4 mm and wall thickness from 1.5 to 1.2 mm. Dynamic cardiac phantoms simulating rodent left ventricular motion in the short-axis view were successfully developed and compared with in vivo imaging. The phantoms can be used for future development work with reduced need of live animals.
format Online
Article
Text
id pubmed-3471072
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-34710722012-11-14 Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging Fortune, Steven Jansen, Maurits A. Anderson, Tom Gray, Gillian A. Schneider, Jürgen E. Hoskins, Peter R. Marshall, Ian Magn Reson Imaging Technical Note The increasing availability of rodent models of human cardiovascular disease has led to a need to translate noninvasive imaging techniques such as magnetic resonance imaging (MRI) from the clinic to the animal laboratory. The aim of this study was to develop phantoms simulating the short-axis view of left ventricular motion of rats and mice, thus reducing the need for live animals in the development of MRI. Cylindrical phantoms were moulded from polyvinyl alcohol (PVA) Cryogel and attached via stiff water-filled tubing to a gear pump. Pulsatile distension of the phantoms was effected by suitable programming of the pump. Cine MRI scanning was carried out at 7 T and compared with in vivo rodent cardiac imaging. Suitable pulsatile performance was achieved with phantoms for which the PVA material had been subjected to two freeze–thaw cycles, resulting in T1 and T2 relaxation time constants of 1656±124 ms and 55±10 ms, respectively. For the rat phantom operating at 240 beats per min (bpm), the dynamic range of the outer diameter was from 10.3 to 12.4 mm with the wall thickness varying between 1.9 and 1.2 mm. Corresponding figures for the mouse phantom at 480 bpm were outer diameter range from 5.4 to 6.4 mm and wall thickness from 1.5 to 1.2 mm. Dynamic cardiac phantoms simulating rodent left ventricular motion in the short-axis view were successfully developed and compared with in vivo imaging. The phantoms can be used for future development work with reduced need of live animals. Elsevier 2012-10 /pmc/articles/PMC3471072/ /pubmed/22770689 http://dx.doi.org/10.1016/j.mri.2012.04.008 Text en © 2012 Elsevier Inc. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Technical Note
Fortune, Steven
Jansen, Maurits A.
Anderson, Tom
Gray, Gillian A.
Schneider, Jürgen E.
Hoskins, Peter R.
Marshall, Ian
Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title_full Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title_fullStr Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title_full_unstemmed Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title_short Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
title_sort development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471072/
https://www.ncbi.nlm.nih.gov/pubmed/22770689
http://dx.doi.org/10.1016/j.mri.2012.04.008
work_keys_str_mv AT fortunesteven developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT jansenmauritsa developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT andersontom developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT graygilliana developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT schneiderjurgene developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT hoskinspeterr developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging
AT marshallian developmentandcharacterizationofrodentcardiacphantomscomparisonwithinvivocardiacimaging