Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) w...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471569/ https://www.ncbi.nlm.nih.gov/pubmed/23130022 |
_version_ | 1782246439939735552 |
---|---|
author | Razmi, Hasan Parvizi, Shaghayegh Khorshidian, Azam |
author_facet | Razmi, Hasan Parvizi, Shaghayegh Khorshidian, Azam |
author_sort | Razmi, Hasan |
collection | PubMed |
description | INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) which tests the physicochemical properties of endodontic sealers. Three samples of each of tested materials including AH26 alone, AH26/amoxicillin and AH26/doxycycline were used to test each of the properties. They were prepared according to ISO protocols. RESULTS: The setting time of studied materials was 46 hours for AH26, 29 hours for AH26/amoxicillin, 49 hours for AH26/doxycycline. Flow test results were as follows, for AH 26, 15.6 mm; AH26/amoxicillin, 14.9 mm; AH26/doxycycline, 14.2 mm. Film thickness was 0.024 mm in AH26, 0.0283 mm in AH26/amoxicillin, 0.0276 mm AH26/doxycycline. The solubility of AH26 was 0.0076%, AH26/amoxicillin, 0.0113%, and for AH26/doxycycline, 0.013 %. Dimensional changes following setting was 0.07 mm, 2.6 mm, and 1.1 mm for AH 26, AH26/amoxicillin, and AH26/doxycycline, respectively. CONCLUSION: The physico-mechanical properties of AH26 antibiotic combinations were superior compared with AH26, with the exception of flow. Also, AH26/amoxicillin had a lower setting time than AH26. However, all values were within an acceptable range which conformed to ISO. |
format | Online Article Text |
id | pubmed-3471569 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-34715692012-11-05 Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations Razmi, Hasan Parvizi, Shaghayegh Khorshidian, Azam Iran Endod J Original Article INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) which tests the physicochemical properties of endodontic sealers. Three samples of each of tested materials including AH26 alone, AH26/amoxicillin and AH26/doxycycline were used to test each of the properties. They were prepared according to ISO protocols. RESULTS: The setting time of studied materials was 46 hours for AH26, 29 hours for AH26/amoxicillin, 49 hours for AH26/doxycycline. Flow test results were as follows, for AH 26, 15.6 mm; AH26/amoxicillin, 14.9 mm; AH26/doxycycline, 14.2 mm. Film thickness was 0.024 mm in AH26, 0.0283 mm in AH26/amoxicillin, 0.0276 mm AH26/doxycycline. The solubility of AH26 was 0.0076%, AH26/amoxicillin, 0.0113%, and for AH26/doxycycline, 0.013 %. Dimensional changes following setting was 0.07 mm, 2.6 mm, and 1.1 mm for AH 26, AH26/amoxicillin, and AH26/doxycycline, respectively. CONCLUSION: The physico-mechanical properties of AH26 antibiotic combinations were superior compared with AH26, with the exception of flow. Also, AH26/amoxicillin had a lower setting time than AH26. However, all values were within an acceptable range which conformed to ISO. Iranian Center for Endodontic Research 2010 2010-02-20 /pmc/articles/PMC3471569/ /pubmed/23130022 Text en Copyright © Iranian Endodontic Journal, 2010. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Razmi, Hasan Parvizi, Shaghayegh Khorshidian, Azam Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title | Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title_full | Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title_fullStr | Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title_full_unstemmed | Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title_short | Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations |
title_sort | comparison of ah26 physicochemical properties with two ah26/antibiotic combinations |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471569/ https://www.ncbi.nlm.nih.gov/pubmed/23130022 |
work_keys_str_mv | AT razmihasan comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations AT parvizishaghayegh comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations AT khorshidianazam comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations |