Cargando…

Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations

INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) w...

Descripción completa

Detalles Bibliográficos
Autores principales: Razmi, Hasan, Parvizi, Shaghayegh, Khorshidian, Azam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Center for Endodontic Research 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471569/
https://www.ncbi.nlm.nih.gov/pubmed/23130022
_version_ 1782246439939735552
author Razmi, Hasan
Parvizi, Shaghayegh
Khorshidian, Azam
author_facet Razmi, Hasan
Parvizi, Shaghayegh
Khorshidian, Azam
author_sort Razmi, Hasan
collection PubMed
description INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) which tests the physicochemical properties of endodontic sealers. Three samples of each of tested materials including AH26 alone, AH26/amoxicillin and AH26/doxycycline were used to test each of the properties. They were prepared according to ISO protocols. RESULTS: The setting time of studied materials was 46 hours for AH26, 29 hours for AH26/amoxicillin, 49 hours for AH26/doxycycline. Flow test results were as follows, for AH 26, 15.6 mm; AH26/amoxicillin, 14.9 mm; AH26/doxycycline, 14.2 mm. Film thickness was 0.024 mm in AH26, 0.0283 mm in AH26/amoxicillin, 0.0276 mm AH26/doxycycline. The solubility of AH26 was 0.0076%, AH26/amoxicillin, 0.0113%, and for AH26/doxycycline, 0.013 %. Dimensional changes following setting was 0.07 mm, 2.6 mm, and 1.1 mm for AH 26, AH26/amoxicillin, and AH26/doxycycline, respectively. CONCLUSION: The physico-mechanical properties of AH26 antibiotic combinations were superior compared with AH26, with the exception of flow. Also, AH26/amoxicillin had a lower setting time than AH26. However, all values were within an acceptable range which conformed to ISO.
format Online
Article
Text
id pubmed-3471569
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Iranian Center for Endodontic Research
record_format MEDLINE/PubMed
spelling pubmed-34715692012-11-05 Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations Razmi, Hasan Parvizi, Shaghayegh Khorshidian, Azam Iran Endod J Original Article INTRODUCTION: The purpose of this study was to compare the setting time and post-setting solubility, flow, film thickness and dimensional changes of AH26 root canal sealer with AH26-Antibiotic combination. MATERIALS AND METHODS: This study was performed according to British standard BS 6876 (2001) which tests the physicochemical properties of endodontic sealers. Three samples of each of tested materials including AH26 alone, AH26/amoxicillin and AH26/doxycycline were used to test each of the properties. They were prepared according to ISO protocols. RESULTS: The setting time of studied materials was 46 hours for AH26, 29 hours for AH26/amoxicillin, 49 hours for AH26/doxycycline. Flow test results were as follows, for AH 26, 15.6 mm; AH26/amoxicillin, 14.9 mm; AH26/doxycycline, 14.2 mm. Film thickness was 0.024 mm in AH26, 0.0283 mm in AH26/amoxicillin, 0.0276 mm AH26/doxycycline. The solubility of AH26 was 0.0076%, AH26/amoxicillin, 0.0113%, and for AH26/doxycycline, 0.013 %. Dimensional changes following setting was 0.07 mm, 2.6 mm, and 1.1 mm for AH 26, AH26/amoxicillin, and AH26/doxycycline, respectively. CONCLUSION: The physico-mechanical properties of AH26 antibiotic combinations were superior compared with AH26, with the exception of flow. Also, AH26/amoxicillin had a lower setting time than AH26. However, all values were within an acceptable range which conformed to ISO. Iranian Center for Endodontic Research 2010 2010-02-20 /pmc/articles/PMC3471569/ /pubmed/23130022 Text en Copyright © Iranian Endodontic Journal, 2010. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Razmi, Hasan
Parvizi, Shaghayegh
Khorshidian, Azam
Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title_full Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title_fullStr Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title_full_unstemmed Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title_short Comparison of AH26 Physicochemical Properties with Two AH26/Antibiotic Combinations
title_sort comparison of ah26 physicochemical properties with two ah26/antibiotic combinations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471569/
https://www.ncbi.nlm.nih.gov/pubmed/23130022
work_keys_str_mv AT razmihasan comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations
AT parvizishaghayegh comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations
AT khorshidianazam comparisonofah26physicochemicalpropertieswithtwoah26antibioticcombinations