Cargando…

Comparing Coronal Discoloration Between AH26 and ZOE Sealers

INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discolora...

Descripción completa

Detalles Bibliográficos
Autores principales: Zare Jahromi, Maryam, Navabi, Amir Arsalan, Ekhtiari, Mahsa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Center for Endodontic Research 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471592/
https://www.ncbi.nlm.nih.gov/pubmed/23130069
_version_ 1782246446500675584
author Zare Jahromi, Maryam
Navabi, Amir Arsalan
Ekhtiari, Mahsa
author_facet Zare Jahromi, Maryam
Navabi, Amir Arsalan
Ekhtiari, Mahsa
author_sort Zare Jahromi, Maryam
collection PubMed
description INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discoloration. The objective of this in vitro study was to evaluate coronal discoloration created by AH26 and ZOE sealers after four months. MATERIALS AND METHODS: Fifty intact human extracted maxillary central incisors were employed. Access cavities were prepared in all samples and root canals were instrumented; coronal orifices were then sealed using self-cure glass ionomer. The teeth were divided into two experimental groups (n=20) according to utilized sealer in pulp chambers including AH26 and Dorifill (ZOE). The remaining 10 teeth served as negative and positive controls (n=5). The access cavities were sealed with self-cure glass ionomer. Teeth were kept in incubator for four month. Preliminary digital images of the teeth were taken and then compared with those related to 4-month follow-up. The images were assessed using Photoshop software. Data was analyzed using paired t-test and independent samples t-test. RESULTS: The teeth which were filled with AH26 sealer showed significantly greater discoloration than those filled with ZOE sealer (Dorifill) (P<0.05). CONCLUSION: AH26 sealer causes greater discoloration of the crown compared to ZOE sealer. Despite the other disadvantage of AH26 sealer, it seems that Dorifill is more esthetically considerate.
format Online
Article
Text
id pubmed-3471592
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Iranian Center for Endodontic Research
record_format MEDLINE/PubMed
spelling pubmed-34715922012-11-05 Comparing Coronal Discoloration Between AH26 and ZOE Sealers Zare Jahromi, Maryam Navabi, Amir Arsalan Ekhtiari, Mahsa Iran Endod J Original Article INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discoloration. The objective of this in vitro study was to evaluate coronal discoloration created by AH26 and ZOE sealers after four months. MATERIALS AND METHODS: Fifty intact human extracted maxillary central incisors were employed. Access cavities were prepared in all samples and root canals were instrumented; coronal orifices were then sealed using self-cure glass ionomer. The teeth were divided into two experimental groups (n=20) according to utilized sealer in pulp chambers including AH26 and Dorifill (ZOE). The remaining 10 teeth served as negative and positive controls (n=5). The access cavities were sealed with self-cure glass ionomer. Teeth were kept in incubator for four month. Preliminary digital images of the teeth were taken and then compared with those related to 4-month follow-up. The images were assessed using Photoshop software. Data was analyzed using paired t-test and independent samples t-test. RESULTS: The teeth which were filled with AH26 sealer showed significantly greater discoloration than those filled with ZOE sealer (Dorifill) (P<0.05). CONCLUSION: AH26 sealer causes greater discoloration of the crown compared to ZOE sealer. Despite the other disadvantage of AH26 sealer, it seems that Dorifill is more esthetically considerate. Iranian Center for Endodontic Research 2011 2011-11-15 /pmc/articles/PMC3471592/ /pubmed/23130069 Text en Copyright © Iranian Endodontic Journal, 2011. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zare Jahromi, Maryam
Navabi, Amir Arsalan
Ekhtiari, Mahsa
Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title_full Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title_fullStr Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title_full_unstemmed Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title_short Comparing Coronal Discoloration Between AH26 and ZOE Sealers
title_sort comparing coronal discoloration between ah26 and zoe sealers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471592/
https://www.ncbi.nlm.nih.gov/pubmed/23130069
work_keys_str_mv AT zarejahromimaryam comparingcoronaldiscolorationbetweenah26andzoesealers
AT navabiamirarsalan comparingcoronaldiscolorationbetweenah26andzoesealers
AT ekhtiarimahsa comparingcoronaldiscolorationbetweenah26andzoesealers