Cargando…
Comparing Coronal Discoloration Between AH26 and ZOE Sealers
INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discolora...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471592/ https://www.ncbi.nlm.nih.gov/pubmed/23130069 |
_version_ | 1782246446500675584 |
---|---|
author | Zare Jahromi, Maryam Navabi, Amir Arsalan Ekhtiari, Mahsa |
author_facet | Zare Jahromi, Maryam Navabi, Amir Arsalan Ekhtiari, Mahsa |
author_sort | Zare Jahromi, Maryam |
collection | PubMed |
description | INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discoloration. The objective of this in vitro study was to evaluate coronal discoloration created by AH26 and ZOE sealers after four months. MATERIALS AND METHODS: Fifty intact human extracted maxillary central incisors were employed. Access cavities were prepared in all samples and root canals were instrumented; coronal orifices were then sealed using self-cure glass ionomer. The teeth were divided into two experimental groups (n=20) according to utilized sealer in pulp chambers including AH26 and Dorifill (ZOE). The remaining 10 teeth served as negative and positive controls (n=5). The access cavities were sealed with self-cure glass ionomer. Teeth were kept in incubator for four month. Preliminary digital images of the teeth were taken and then compared with those related to 4-month follow-up. The images were assessed using Photoshop software. Data was analyzed using paired t-test and independent samples t-test. RESULTS: The teeth which were filled with AH26 sealer showed significantly greater discoloration than those filled with ZOE sealer (Dorifill) (P<0.05). CONCLUSION: AH26 sealer causes greater discoloration of the crown compared to ZOE sealer. Despite the other disadvantage of AH26 sealer, it seems that Dorifill is more esthetically considerate. |
format | Online Article Text |
id | pubmed-3471592 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-34715922012-11-05 Comparing Coronal Discoloration Between AH26 and ZOE Sealers Zare Jahromi, Maryam Navabi, Amir Arsalan Ekhtiari, Mahsa Iran Endod J Original Article INTRODUCTION: Intrinsic tooth discolorations after endodontic treatment are principally attributed to the composition of necrotic pulp tissue, hemorrhage within the pulp cavity, endodontic medicaments and/or filling materials. Residual sealer left in pulp chamber after obturation can cause discoloration. The objective of this in vitro study was to evaluate coronal discoloration created by AH26 and ZOE sealers after four months. MATERIALS AND METHODS: Fifty intact human extracted maxillary central incisors were employed. Access cavities were prepared in all samples and root canals were instrumented; coronal orifices were then sealed using self-cure glass ionomer. The teeth were divided into two experimental groups (n=20) according to utilized sealer in pulp chambers including AH26 and Dorifill (ZOE). The remaining 10 teeth served as negative and positive controls (n=5). The access cavities were sealed with self-cure glass ionomer. Teeth were kept in incubator for four month. Preliminary digital images of the teeth were taken and then compared with those related to 4-month follow-up. The images were assessed using Photoshop software. Data was analyzed using paired t-test and independent samples t-test. RESULTS: The teeth which were filled with AH26 sealer showed significantly greater discoloration than those filled with ZOE sealer (Dorifill) (P<0.05). CONCLUSION: AH26 sealer causes greater discoloration of the crown compared to ZOE sealer. Despite the other disadvantage of AH26 sealer, it seems that Dorifill is more esthetically considerate. Iranian Center for Endodontic Research 2011 2011-11-15 /pmc/articles/PMC3471592/ /pubmed/23130069 Text en Copyright © Iranian Endodontic Journal, 2011. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Zare Jahromi, Maryam Navabi, Amir Arsalan Ekhtiari, Mahsa Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title | Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title_full | Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title_fullStr | Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title_full_unstemmed | Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title_short | Comparing Coronal Discoloration Between AH26 and ZOE Sealers |
title_sort | comparing coronal discoloration between ah26 and zoe sealers |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471592/ https://www.ncbi.nlm.nih.gov/pubmed/23130069 |
work_keys_str_mv | AT zarejahromimaryam comparingcoronaldiscolorationbetweenah26andzoesealers AT navabiamirarsalan comparingcoronaldiscolorationbetweenah26andzoesealers AT ekhtiarimahsa comparingcoronaldiscolorationbetweenah26andzoesealers |