Cargando…
Undersampled Cine 3D tagging for rapid assessment of cardiac motion
BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient coop...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472184/ https://www.ncbi.nlm.nih.gov/pubmed/22935509 http://dx.doi.org/10.1186/1532-429X-14-60 |
_version_ | 1782246542305918976 |
---|---|
author | Stoeck, Christian T Manka, Robert Boesiger, Peter Kozerke, Sebastian |
author_facet | Stoeck, Christian T Manka, Robert Boesiger, Peter Kozerke, Sebastian |
author_sort | Stoeck, Christian T |
collection | PubMed |
description | BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. METHODS: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. RESULTS: In computer simulations, the error for circumferential shortening was 2.8 ± 2.3% and 2.7 ± 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 ± 1.9% and 3.0 ± 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of −0.14 ± 5.18% and 0.71 ± 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 ± 1.8° and 0.73 ± 1.67° for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced (p < 0.002 for all patients) in regions with late gadolinium enhancement. CONCLUSION: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches. |
format | Online Article Text |
id | pubmed-3472184 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34721842012-10-23 Undersampled Cine 3D tagging for rapid assessment of cardiac motion Stoeck, Christian T Manka, Robert Boesiger, Peter Kozerke, Sebastian J Cardiovasc Magn Reson Research BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. METHODS: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. RESULTS: In computer simulations, the error for circumferential shortening was 2.8 ± 2.3% and 2.7 ± 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 ± 1.9% and 3.0 ± 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of −0.14 ± 5.18% and 0.71 ± 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 ± 1.8° and 0.73 ± 1.67° for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced (p < 0.002 for all patients) in regions with late gadolinium enhancement. CONCLUSION: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches. BioMed Central 2012-08-30 /pmc/articles/PMC3472184/ /pubmed/22935509 http://dx.doi.org/10.1186/1532-429X-14-60 Text en Copyright ©2012 Stoeck et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Stoeck, Christian T Manka, Robert Boesiger, Peter Kozerke, Sebastian Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title | Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title_full | Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title_fullStr | Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title_full_unstemmed | Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title_short | Undersampled Cine 3D tagging for rapid assessment of cardiac motion |
title_sort | undersampled cine 3d tagging for rapid assessment of cardiac motion |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472184/ https://www.ncbi.nlm.nih.gov/pubmed/22935509 http://dx.doi.org/10.1186/1532-429X-14-60 |
work_keys_str_mv | AT stoeckchristiant undersampledcine3dtaggingforrapidassessmentofcardiacmotion AT mankarobert undersampledcine3dtaggingforrapidassessmentofcardiacmotion AT boesigerpeter undersampledcine3dtaggingforrapidassessmentofcardiacmotion AT kozerkesebastian undersampledcine3dtaggingforrapidassessmentofcardiacmotion |