Cargando…

Undersampled Cine 3D tagging for rapid assessment of cardiac motion

BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient coop...

Descripción completa

Detalles Bibliográficos
Autores principales: Stoeck, Christian T, Manka, Robert, Boesiger, Peter, Kozerke, Sebastian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472184/
https://www.ncbi.nlm.nih.gov/pubmed/22935509
http://dx.doi.org/10.1186/1532-429X-14-60
_version_ 1782246542305918976
author Stoeck, Christian T
Manka, Robert
Boesiger, Peter
Kozerke, Sebastian
author_facet Stoeck, Christian T
Manka, Robert
Boesiger, Peter
Kozerke, Sebastian
author_sort Stoeck, Christian T
collection PubMed
description BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. METHODS: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. RESULTS: In computer simulations, the error for circumferential shortening was 2.8 ± 2.3% and 2.7 ± 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 ± 1.9% and 3.0 ± 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of −0.14 ± 5.18% and 0.71 ± 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 ± 1.8° and 0.73 ± 1.67° for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced (p < 0.002 for all patients) in regions with late gadolinium enhancement. CONCLUSION: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches.
format Online
Article
Text
id pubmed-3472184
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34721842012-10-23 Undersampled Cine 3D tagging for rapid assessment of cardiac motion Stoeck, Christian T Manka, Robert Boesiger, Peter Kozerke, Sebastian J Cardiovasc Magn Reson Research BACKGROUND: CMR allows investigating cardiac contraction, rotation and torsion non-invasively by the use of tagging sequences. Three-dimensional tagging has been proposed to cover the whole-heart but data acquisition requires three consecutive breath holds and hence demands considerable patient cooperation. In this study we have implemented and studied k-t undersampled cine 3D tagging in conjunction with k-t PCA reconstruction to potentially permit for single breath-hold acquisitions. METHODS: The performance of undersampled cine 3D tagging was investigated using computer simulations and in-vivo measurements in 8 healthy subjects and 5 patients with myocardial infarction. Fully sampled data was obtained and compared to retrospectively and prospectively undersampled acquisitions. Fully sampled data was acquired in three consecutive breath holds. Prospectively undersampled data was obtained within a single breath hold. Based on harmonic phase (HARP) analysis, circumferential shortening, rotation and torsion were compared between fully sampled and undersampled data using Bland-Altman and linear regression analysis. RESULTS: In computer simulations, the error for circumferential shortening was 2.8 ± 2.3% and 2.7 ± 2.1% for undersampling rates of R = 3 and 4 respectively. Errors in ventricular rotation were 2.5 ± 1.9% and 3.0 ± 2.2% for R = 3 and 4. Comparison of results from fully sampled in-vivo data acquired with prospectively undersampled acquisitions showed a mean difference in circumferential shortening of −0.14 ± 5.18% and 0.71 ± 6.16% for R = 3 and 4. The mean differences in rotation were 0.44 ± 1.8° and 0.73 ± 1.67° for R = 3 and 4, respectively. In patients peak, circumferential shortening was significantly reduced (p < 0.002 for all patients) in regions with late gadolinium enhancement. CONCLUSION: Undersampled cine 3D tagging enables significant reduction in scan time of whole-heart tagging and facilitates quantification of shortening, rotation and torsion of the left ventricle without adding significant errors compared to previous 3D tagging approaches. BioMed Central 2012-08-30 /pmc/articles/PMC3472184/ /pubmed/22935509 http://dx.doi.org/10.1186/1532-429X-14-60 Text en Copyright ©2012 Stoeck et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Stoeck, Christian T
Manka, Robert
Boesiger, Peter
Kozerke, Sebastian
Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title_full Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title_fullStr Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title_full_unstemmed Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title_short Undersampled Cine 3D tagging for rapid assessment of cardiac motion
title_sort undersampled cine 3d tagging for rapid assessment of cardiac motion
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472184/
https://www.ncbi.nlm.nih.gov/pubmed/22935509
http://dx.doi.org/10.1186/1532-429X-14-60
work_keys_str_mv AT stoeckchristiant undersampledcine3dtaggingforrapidassessmentofcardiacmotion
AT mankarobert undersampledcine3dtaggingforrapidassessmentofcardiacmotion
AT boesigerpeter undersampledcine3dtaggingforrapidassessmentofcardiacmotion
AT kozerkesebastian undersampledcine3dtaggingforrapidassessmentofcardiacmotion