Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method

BACKGROUND: Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS: MCNP-4C and MCNPX Monte...

Descripción completa

Detalles Bibliográficos
Autores principales: Bahreyni Toossi, Mohammad Taghi, Ghorbani, Mahdi, Mowlavi, Ali Asghar, Meigooni, Ali Soleimani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Versita, Warsaw 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472933/
https://www.ncbi.nlm.nih.gov/pubmed/23077455
http://dx.doi.org/10.2478/v10019-012-0005-3
_version_ 1782246689111801856
author Bahreyni Toossi, Mohammad Taghi
Ghorbani, Mahdi
Mowlavi, Ali Asghar
Meigooni, Ali Soleimani
author_facet Bahreyni Toossi, Mohammad Taghi
Ghorbani, Mahdi
Mowlavi, Ali Asghar
Meigooni, Ali Soleimani
author_sort Bahreyni Toossi, Mohammad Taghi
collection PubMed
description BACKGROUND: Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS: MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution, radial dose function and 2D anisotropy function of the source. These parameters of this source are compared with the available data for Ralstron (60)Co and microSelectron(192)Ir sources. Besides, a superimposition method was developed to extend the obtained results for the GZP6 source No. 3 to other GZP6 sources. RESULTS: The simulated value for dose rate constant for GZP6 source was 1.104±0.03 cGyh-1U-1. The graphical and tabulated radial dose function and 2D anisotropy function of this source are presented here. The results of these investigations show that the dosimetric parameters of GZP6 source are comparable to those for the Ralstron source. While dose rate constant for the two (60)Co sources are similar to that for the microSelectron(192)Ir source, there are differences between radial dose function and anisotropy functions. Radial dose function of the (192)Ir source is less steep than both (60)Co source models. In addition, the (60)Co sources are showing more isotropic dose distribution than the (192)Ir source. CONCLUSIONS: The superimposition method is applicable to produce dose distributions for other source arrangements from the dose distribution of a single source. The calculated dosimetric quantities of this new source can be introduced as input data to the GZP6 treatment planning system (TPS) and to validate the performance of the TPS.
format Online
Article
Text
id pubmed-3472933
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Versita, Warsaw
record_format MEDLINE/PubMed
spelling pubmed-34729332012-10-17 Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method Bahreyni Toossi, Mohammad Taghi Ghorbani, Mahdi Mowlavi, Ali Asghar Meigooni, Ali Soleimani Radiol Oncol Research Article BACKGROUND: Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS: MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution, radial dose function and 2D anisotropy function of the source. These parameters of this source are compared with the available data for Ralstron (60)Co and microSelectron(192)Ir sources. Besides, a superimposition method was developed to extend the obtained results for the GZP6 source No. 3 to other GZP6 sources. RESULTS: The simulated value for dose rate constant for GZP6 source was 1.104±0.03 cGyh-1U-1. The graphical and tabulated radial dose function and 2D anisotropy function of this source are presented here. The results of these investigations show that the dosimetric parameters of GZP6 source are comparable to those for the Ralstron source. While dose rate constant for the two (60)Co sources are similar to that for the microSelectron(192)Ir source, there are differences between radial dose function and anisotropy functions. Radial dose function of the (192)Ir source is less steep than both (60)Co source models. In addition, the (60)Co sources are showing more isotropic dose distribution than the (192)Ir source. CONCLUSIONS: The superimposition method is applicable to produce dose distributions for other source arrangements from the dose distribution of a single source. The calculated dosimetric quantities of this new source can be introduced as input data to the GZP6 treatment planning system (TPS) and to validate the performance of the TPS. Versita, Warsaw 2012-01-02 /pmc/articles/PMC3472933/ /pubmed/23077455 http://dx.doi.org/10.2478/v10019-012-0005-3 Text en Copyright © by Association of Radiology & Oncology http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Research Article
Bahreyni Toossi, Mohammad Taghi
Ghorbani, Mahdi
Mowlavi, Ali Asghar
Meigooni, Ali Soleimani
Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title_full Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title_fullStr Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title_full_unstemmed Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title_short Dosimetric characterizations of GZP6 (60)Co high dose rate brachytherapy sources: application of superimposition method
title_sort dosimetric characterizations of gzp6 (60)co high dose rate brachytherapy sources: application of superimposition method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3472933/
https://www.ncbi.nlm.nih.gov/pubmed/23077455
http://dx.doi.org/10.2478/v10019-012-0005-3
work_keys_str_mv AT bahreynitoossimohammadtaghi dosimetriccharacterizationsofgzp660cohighdoseratebrachytherapysourcesapplicationofsuperimpositionmethod
AT ghorbanimahdi dosimetriccharacterizationsofgzp660cohighdoseratebrachytherapysourcesapplicationofsuperimpositionmethod
AT mowlavialiasghar dosimetriccharacterizationsofgzp660cohighdoseratebrachytherapysourcesapplicationofsuperimpositionmethod
AT meigoonialisoleimani dosimetriccharacterizationsofgzp660cohighdoseratebrachytherapysourcesapplicationofsuperimpositionmethod