Cargando…
Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan
PURPOSE: To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. MATERIALS AND METHODS: We determined the radiation pneumonitis (RP) a...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Radiation Oncology
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3475962/ https://www.ncbi.nlm.nih.gov/pubmed/23120743 http://dx.doi.org/10.3857/roj.2012.30.1.43 |
_version_ | 1782247019955355648 |
---|---|
author | Kim, BoKyong Park, Hee Chul Oh, Dongryul Shin, Eun Hyuk Ahn, Yong Chan Kim, Jinsung Han, Youngyih |
author_facet | Kim, BoKyong Park, Hee Chul Oh, Dongryul Shin, Eun Hyuk Ahn, Yong Chan Kim, Jinsung Han, Youngyih |
author_sort | Kim, BoKyong |
collection | PubMed |
description | PURPOSE: To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. MATERIALS AND METHODS: We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectively reviewed the medical records of lung cancer patients treated with curative 3-dimensional conformal radiation therapy (3D-CRT). The biological event was defined as RP of the Radiation Therapy Oncology Group (RTOG) grade III or more. RESULTS: The DVH management software consisted of three parts (pre-existing DVH database, graphical tool, and Pinnacle(3) script). The pre-existing DVH data were retrieved from 128 patients. RP events were tagged to the specific DVH data through retrospective review of patients' medical records. The graphical tool was developed to present the complication histogram derived from the pre-existing database (DVH and RP) and was implemented into the radiation treatment planning (RTP) system, Pinnacle(3) v8.0 (Phillips Healthcare). The software was designed for the pre-existing database to be updated easily by tagging the specific DVH data with the new incidence of RP events at the time of patients' follow-up. CONCLUSION: We developed the DVH management software as an effective tool to incorporate the phenomenological consequences derived from the pre-existing database in the evaluation of a new RT plan. It can be used not only for lung cancer patients but also for the other disease site with different toxicity parameters. |
format | Online Article Text |
id | pubmed-3475962 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Society for Radiation Oncology |
record_format | MEDLINE/PubMed |
spelling | pubmed-34759622012-11-01 Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan Kim, BoKyong Park, Hee Chul Oh, Dongryul Shin, Eun Hyuk Ahn, Yong Chan Kim, Jinsung Han, Youngyih Radiation Oncol J Original Article PURPOSE: To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. MATERIALS AND METHODS: We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectively reviewed the medical records of lung cancer patients treated with curative 3-dimensional conformal radiation therapy (3D-CRT). The biological event was defined as RP of the Radiation Therapy Oncology Group (RTOG) grade III or more. RESULTS: The DVH management software consisted of three parts (pre-existing DVH database, graphical tool, and Pinnacle(3) script). The pre-existing DVH data were retrieved from 128 patients. RP events were tagged to the specific DVH data through retrospective review of patients' medical records. The graphical tool was developed to present the complication histogram derived from the pre-existing database (DVH and RP) and was implemented into the radiation treatment planning (RTP) system, Pinnacle(3) v8.0 (Phillips Healthcare). The software was designed for the pre-existing database to be updated easily by tagging the specific DVH data with the new incidence of RP events at the time of patients' follow-up. CONCLUSION: We developed the DVH management software as an effective tool to incorporate the phenomenological consequences derived from the pre-existing database in the evaluation of a new RT plan. It can be used not only for lung cancer patients but also for the other disease site with different toxicity parameters. The Korean Society for Radiation Oncology 2012-03 2012-03-31 /pmc/articles/PMC3475962/ /pubmed/23120743 http://dx.doi.org/10.3857/roj.2012.30.1.43 Text en Copyright © 2012. The Korean Society for Radiation Oncology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, BoKyong Park, Hee Chul Oh, Dongryul Shin, Eun Hyuk Ahn, Yong Chan Kim, Jinsung Han, Youngyih Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title | Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title_full | Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title_fullStr | Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title_full_unstemmed | Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title_short | Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan |
title_sort | development of the dvh management software for the biologically-guided evaluation of radiotherapy plan |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3475962/ https://www.ncbi.nlm.nih.gov/pubmed/23120743 http://dx.doi.org/10.3857/roj.2012.30.1.43 |
work_keys_str_mv | AT kimbokyong developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT parkheechul developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT ohdongryul developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT shineunhyuk developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT ahnyongchan developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT kimjinsung developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan AT hanyoungyih developmentofthedvhmanagementsoftwareforthebiologicallyguidedevaluationofradiotherapyplan |