Cargando…

Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents

Objectives. This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Study Design. Crown copings were fabricated using: (1) direct metal las...

Descripción completa

Detalles Bibliográficos
Autores principales: Castillo-de-Oyagüe, Raquel, Sánchez-Turrión, Andrés, López-Lozano, José F., Albaladejo, Alberto, Torres-Lagares, Daniel, Montero, Javier, Suárez-García, Maria J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3476024/
https://www.ncbi.nlm.nih.gov/pubmed/22322524
http://dx.doi.org/10.4317/medoral.17997
_version_ 1782247030821748736
author Castillo-de-Oyagüe, Raquel
Sánchez-Turrión, Andrés
López-Lozano, José F.
Albaladejo, Alberto
Torres-Lagares, Daniel
Montero, Javier
Suárez-García, Maria J.
author_facet Castillo-de-Oyagüe, Raquel
Sánchez-Turrión, Andrés
López-Lozano, José F.
Albaladejo, Alberto
Torres-Lagares, Daniel
Montero, Javier
Suárez-García, Maria J.
author_sort Castillo-de-Oyagüe, Raquel
collection PubMed
description Objectives. This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Study Design. Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure. Each alloy group was randomly divided into 5 subgroups (n = 10 each) according to the cement system utilized: Subgroup 1 (KC) used resin-modified glass-ionomer Ketac Cem Plus; Subgroup 2 (PF) used Panavia F 2.0 dual-cure resin cement; Subgroup 3 (RXU) used RelyX Unicem 2 Automix self-adhesive dual-cure resin cement; Subgroup 4 (PIC) used acrylic/urethane-based temporary Premier Implant Cement; and Subgroup 5 (DT) used acrylic/urethane-based temporary DentoTemp cement. Vertical misfit was measured by scanning electron microscopy (SEM). Two-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, and cement type on vertical misfit. The statistical significance was set at α = 0.05. Results. The alloy/manufacturing technique and the luting cement affected the vertical discrepancy (p < 0.001). For each cement type, LS samples exhibited the best fit (p < 0.01) whereas CC and CT frames were statistically similar. Within each alloy group, PF and RXU provided comparably greater discrepancies than KC, PIC, and DT, which showed no differences. Conclusions. Laser sintering may be an alternative to vacuum-casting of base metals to obtain passive-fitting implant-supported crown copings. The best marginal adaptation corresponded to laser sintered structures luted with glass-ionomer KC, or temporary PIC or DT cements. The highest discrepancies were recorded for Co-Cr and Ti cast frameworks bonded with PF or RXU resinous agents. All groups were within the clinically acceptable misfit range. Key words:Dental alloy, laser sintering, implant-supported prostheses, vertical discrepancy, vertical misfit.
format Online
Article
Text
id pubmed-3476024
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-34760242012-10-19 Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents Castillo-de-Oyagüe, Raquel Sánchez-Turrión, Andrés López-Lozano, José F. Albaladejo, Alberto Torres-Lagares, Daniel Montero, Javier Suárez-García, Maria J. Med Oral Patol Oral Cir Bucal Research-Article Objectives. This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Study Design. Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure. Each alloy group was randomly divided into 5 subgroups (n = 10 each) according to the cement system utilized: Subgroup 1 (KC) used resin-modified glass-ionomer Ketac Cem Plus; Subgroup 2 (PF) used Panavia F 2.0 dual-cure resin cement; Subgroup 3 (RXU) used RelyX Unicem 2 Automix self-adhesive dual-cure resin cement; Subgroup 4 (PIC) used acrylic/urethane-based temporary Premier Implant Cement; and Subgroup 5 (DT) used acrylic/urethane-based temporary DentoTemp cement. Vertical misfit was measured by scanning electron microscopy (SEM). Two-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, and cement type on vertical misfit. The statistical significance was set at α = 0.05. Results. The alloy/manufacturing technique and the luting cement affected the vertical discrepancy (p < 0.001). For each cement type, LS samples exhibited the best fit (p < 0.01) whereas CC and CT frames were statistically similar. Within each alloy group, PF and RXU provided comparably greater discrepancies than KC, PIC, and DT, which showed no differences. Conclusions. Laser sintering may be an alternative to vacuum-casting of base metals to obtain passive-fitting implant-supported crown copings. The best marginal adaptation corresponded to laser sintered structures luted with glass-ionomer KC, or temporary PIC or DT cements. The highest discrepancies were recorded for Co-Cr and Ti cast frameworks bonded with PF or RXU resinous agents. All groups were within the clinically acceptable misfit range. Key words:Dental alloy, laser sintering, implant-supported prostheses, vertical discrepancy, vertical misfit. Medicina Oral S.L. 2012-07 2012-02-09 /pmc/articles/PMC3476024/ /pubmed/22322524 http://dx.doi.org/10.4317/medoral.17997 Text en Copyright: © 2012 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research-Article
Castillo-de-Oyagüe, Raquel
Sánchez-Turrión, Andrés
López-Lozano, José F.
Albaladejo, Alberto
Torres-Lagares, Daniel
Montero, Javier
Suárez-García, Maria J.
Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title_full Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title_fullStr Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title_full_unstemmed Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title_short Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
title_sort vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3476024/
https://www.ncbi.nlm.nih.gov/pubmed/22322524
http://dx.doi.org/10.4317/medoral.17997
work_keys_str_mv AT castillodeoyagueraquel verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT sanchezturrionandres verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT lopezlozanojosef verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT albaladejoalberto verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT torreslagaresdaniel verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT monterojavier verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents
AT suarezgarciamariaj verticalmisfitoflasersinteredandvacuumcastimplantsupportedcrowncopingslutedwithdefinitiveandtemporarylutingagents