Cargando…

Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction

PURPOSE: The aim of this study was to evaluate the clinical outcome and differences in anterior–posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation. METHODS: Clinical outcome was evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Frosch, Stephan, Rittstieg, Anne, Balcarek, Peter, Walde, Tim Alexander, Schüttrumpf, Jan P., Wachowski, Martin M., Stürmer, Klaus M., Frosch, Karl-Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3477476/
https://www.ncbi.nlm.nih.gov/pubmed/22290125
http://dx.doi.org/10.1007/s00167-011-1875-4
_version_ 1782247219716423680
author Frosch, Stephan
Rittstieg, Anne
Balcarek, Peter
Walde, Tim Alexander
Schüttrumpf, Jan P.
Wachowski, Martin M.
Stürmer, Klaus M.
Frosch, Karl-Heinz
author_facet Frosch, Stephan
Rittstieg, Anne
Balcarek, Peter
Walde, Tim Alexander
Schüttrumpf, Jan P.
Wachowski, Martin M.
Stürmer, Klaus M.
Frosch, Karl-Heinz
author_sort Frosch, Stephan
collection PubMed
description PURPOSE: The aim of this study was to evaluate the clinical outcome and differences in anterior–posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation. METHODS: Clinical outcome was evaluated among 59 patients 1 year after arthroscopic ACL reconstruction with hamstrings graft in a prospective, non-randomised study. In 31 cases, femoral fixation of the graft was performed using a bioabsorbable interference screw. In 28 cases, two bioabsorbable cross pins were used for femoral fixation. Patients were evaluated using Tegner, Lysholm and Marshall scores, the visual analogue scale for pain and KT-1000 arthrometer measurement. RESULTS: No significant difference (P ≥ 0.05) was observed at follow-up for the knee scores. The average Tegner score was 5.83 points (±2.00) for the interference screw fixation and 5.83 points (±1.24) for the cross pin fixation; the average Lysholm score was 93.58 (±5.79) to 92.72 (±6.34) points; and the average Marshall score 46.72 (±2.4) to 47.30 (±2.35) points. No significant difference was found for the visual analogue scale for pain. KT-1000 arthrometer measurement revealed a significant (P < 0.05) difference in the mean side-to-side anterior translation at all applied forces. At 67 N, the mean difference was 1.53 mm (±1.24) in the interference screw group and 0.47 mm (±1.18) in the cross pin group (P < 0.05). At 89 N, the mean differences were 1.85 mm (±1.29) versus 0.59 mm (±1.59), respectively, (P < 0.05), and maximum manual displacements were 2.02 mm (±1.26) versus 1.22 mm (1.18; P < 0.05). CONCLUSIONS: In ACL reconstruction with hamstrings graft, similar clinical results are obtained for the use of bioabsorbable cross pins when compared to bioabsorbable interference screws for femoral fixation. Cross pin fixation was superior with regard to the anteroposterior laxity as measured with KT-1000.
format Online
Article
Text
id pubmed-3477476
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-34774762012-10-31 Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction Frosch, Stephan Rittstieg, Anne Balcarek, Peter Walde, Tim Alexander Schüttrumpf, Jan P. Wachowski, Martin M. Stürmer, Klaus M. Frosch, Karl-Heinz Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: The aim of this study was to evaluate the clinical outcome and differences in anterior–posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation. METHODS: Clinical outcome was evaluated among 59 patients 1 year after arthroscopic ACL reconstruction with hamstrings graft in a prospective, non-randomised study. In 31 cases, femoral fixation of the graft was performed using a bioabsorbable interference screw. In 28 cases, two bioabsorbable cross pins were used for femoral fixation. Patients were evaluated using Tegner, Lysholm and Marshall scores, the visual analogue scale for pain and KT-1000 arthrometer measurement. RESULTS: No significant difference (P ≥ 0.05) was observed at follow-up for the knee scores. The average Tegner score was 5.83 points (±2.00) for the interference screw fixation and 5.83 points (±1.24) for the cross pin fixation; the average Lysholm score was 93.58 (±5.79) to 92.72 (±6.34) points; and the average Marshall score 46.72 (±2.4) to 47.30 (±2.35) points. No significant difference was found for the visual analogue scale for pain. KT-1000 arthrometer measurement revealed a significant (P < 0.05) difference in the mean side-to-side anterior translation at all applied forces. At 67 N, the mean difference was 1.53 mm (±1.24) in the interference screw group and 0.47 mm (±1.18) in the cross pin group (P < 0.05). At 89 N, the mean differences were 1.85 mm (±1.29) versus 0.59 mm (±1.59), respectively, (P < 0.05), and maximum manual displacements were 2.02 mm (±1.26) versus 1.22 mm (1.18; P < 0.05). CONCLUSIONS: In ACL reconstruction with hamstrings graft, similar clinical results are obtained for the use of bioabsorbable cross pins when compared to bioabsorbable interference screws for femoral fixation. Cross pin fixation was superior with regard to the anteroposterior laxity as measured with KT-1000. Springer-Verlag 2012-01-31 2012 /pmc/articles/PMC3477476/ /pubmed/22290125 http://dx.doi.org/10.1007/s00167-011-1875-4 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Knee
Frosch, Stephan
Rittstieg, Anne
Balcarek, Peter
Walde, Tim Alexander
Schüttrumpf, Jan P.
Wachowski, Martin M.
Stürmer, Klaus M.
Frosch, Karl-Heinz
Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title_full Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title_fullStr Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title_full_unstemmed Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title_short Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
title_sort bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after acl reconstruction
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3477476/
https://www.ncbi.nlm.nih.gov/pubmed/22290125
http://dx.doi.org/10.1007/s00167-011-1875-4
work_keys_str_mv AT froschstephan bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT rittstieganne bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT balcarekpeter bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT waldetimalexander bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT schuttrumpfjanp bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT wachowskimartinm bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT sturmerklausm bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction
AT froschkarlheinz bioabsorbableinterferencescrewversusbioabsorbablecrosspinsinfluenceoffemoralgraftfixationontheclinicaloutcomeafteraclreconstruction