Cargando…

A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate

A novel lateral flow immunoassay (LFIA) signal amplification strategy for the detection of Cry1Ab based on amplification via a polylysine (PL) chain and biotin-streptavidin system (BSAS) is described. In this system, multiple fluorescence dyes (FL) were directly coated on the surface of PL and conju...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Chunxiang, Wu, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3478804/
https://www.ncbi.nlm.nih.gov/pubmed/23112677
http://dx.doi.org/10.3390/s120911684
_version_ 1782247349474557952
author Chen, Chunxiang
Wu, Jian
author_facet Chen, Chunxiang
Wu, Jian
author_sort Chen, Chunxiang
collection PubMed
description A novel lateral flow immunoassay (LFIA) signal amplification strategy for the detection of Cry1Ab based on amplification via a polylysine (PL) chain and biotin-streptavidin system (BSAS) is described. In this system, multiple fluorescence dyes (FL) were directly coated on the surface of PL and conjugated with antibody via the BSAS for construction of novel signal amplification (FLPL-BSAS-mAb1) conjugates, in which FL, PL and BSAS were employed to improve the sensitivity of LFIA. Compared with conventional LFIA, the sensitivity of FLPL-BSAS-mAb1-based LFIA was increased by approximately 100-fold. Quantified linearity was achieved in the value range of 0–1,000 pg/mL. The limit of detection (LOD) was reached 10 pg/mL after optimization of reaction conditions. To our knowledge, this represents one of the most sensitive LFIA for Cry1Ab yet reported. Furthermore, the detection time for this method was about 10 min. Therefore, it should be an attractive alternative compared to conventional immunoassays in routine control for Cry1Ab.
format Online
Article
Text
id pubmed-3478804
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-34788042012-10-30 A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate Chen, Chunxiang Wu, Jian Sensors (Basel) Article A novel lateral flow immunoassay (LFIA) signal amplification strategy for the detection of Cry1Ab based on amplification via a polylysine (PL) chain and biotin-streptavidin system (BSAS) is described. In this system, multiple fluorescence dyes (FL) were directly coated on the surface of PL and conjugated with antibody via the BSAS for construction of novel signal amplification (FLPL-BSAS-mAb1) conjugates, in which FL, PL and BSAS were employed to improve the sensitivity of LFIA. Compared with conventional LFIA, the sensitivity of FLPL-BSAS-mAb1-based LFIA was increased by approximately 100-fold. Quantified linearity was achieved in the value range of 0–1,000 pg/mL. The limit of detection (LOD) was reached 10 pg/mL after optimization of reaction conditions. To our knowledge, this represents one of the most sensitive LFIA for Cry1Ab yet reported. Furthermore, the detection time for this method was about 10 min. Therefore, it should be an attractive alternative compared to conventional immunoassays in routine control for Cry1Ab. Molecular Diversity Preservation International (MDPI) 2012-08-27 /pmc/articles/PMC3478804/ /pubmed/23112677 http://dx.doi.org/10.3390/s120911684 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Chen, Chunxiang
Wu, Jian
A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title_full A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title_fullStr A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title_full_unstemmed A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title_short A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
title_sort fast and sensitive quantitative lateral flow immunoassay for cry1ab based on a novel signal amplification conjugate
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3478804/
https://www.ncbi.nlm.nih.gov/pubmed/23112677
http://dx.doi.org/10.3390/s120911684
work_keys_str_mv AT chenchunxiang afastandsensitivequantitativelateralflowimmunoassayforcry1abbasedonanovelsignalamplificationconjugate
AT wujian afastandsensitivequantitativelateralflowimmunoassayforcry1abbasedonanovelsignalamplificationconjugate
AT chenchunxiang fastandsensitivequantitativelateralflowimmunoassayforcry1abbasedonanovelsignalamplificationconjugate
AT wujian fastandsensitivequantitativelateralflowimmunoassayforcry1abbasedonanovelsignalamplificationconjugate