Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years
BACKGROUND: A retained intrauterine device is a rare, but easily correctable, cause of postmenopausal bleeding (PMB). CASE: A 64-year-old woman presented to her gynecologist with PMB. Sonographic evaluation of the endometrium revealed the presence of a Cu-7 IUD retained for at least 30 years. Hyster...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Laparoendoscopic Surgeons
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3481229/ https://www.ncbi.nlm.nih.gov/pubmed/23477190 http://dx.doi.org/10.4293/108680812X13427982376743 |
_version_ | 1782247704574820352 |
---|---|
author | Wagner, Corey A. Gimpelson, Richard J. |
author_facet | Wagner, Corey A. Gimpelson, Richard J. |
author_sort | Wagner, Corey A. |
collection | PubMed |
description | BACKGROUND: A retained intrauterine device is a rare, but easily correctable, cause of postmenopausal bleeding (PMB). CASE: A 64-year-old woman presented to her gynecologist with PMB. Sonographic evaluation of the endometrium revealed the presence of a Cu-7 IUD retained for at least 30 years. Hysteroscopically assisted retrieval of the IUD resulted in complete resolution of symptoms. CONCLUSION: A retained IUD should be considered in the differential diagnosis for PMB. In addition, the authors recommend pelvic sonography as the first-line diagnostic modality for PMB to aid the diagnosis of retained IUD as well as other pathology. |
format | Online Article Text |
id | pubmed-3481229 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Society of Laparoendoscopic Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-34812292012-11-02 Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years Wagner, Corey A. Gimpelson, Richard J. JSLS Case Reports BACKGROUND: A retained intrauterine device is a rare, but easily correctable, cause of postmenopausal bleeding (PMB). CASE: A 64-year-old woman presented to her gynecologist with PMB. Sonographic evaluation of the endometrium revealed the presence of a Cu-7 IUD retained for at least 30 years. Hysteroscopically assisted retrieval of the IUD resulted in complete resolution of symptoms. CONCLUSION: A retained IUD should be considered in the differential diagnosis for PMB. In addition, the authors recommend pelvic sonography as the first-line diagnostic modality for PMB to aid the diagnosis of retained IUD as well as other pathology. Society of Laparoendoscopic Surgeons 2012 /pmc/articles/PMC3481229/ /pubmed/23477190 http://dx.doi.org/10.4293/108680812X13427982376743 Text en © 2012 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way. |
spellingShingle | Case Reports Wagner, Corey A. Gimpelson, Richard J. Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title | Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title_full | Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title_fullStr | Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title_full_unstemmed | Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title_short | Postmenopausal Bleeding due to a Cu-7 Intrauterine Device Retained for Thirty Years |
title_sort | postmenopausal bleeding due to a cu-7 intrauterine device retained for thirty years |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3481229/ https://www.ncbi.nlm.nih.gov/pubmed/23477190 http://dx.doi.org/10.4293/108680812X13427982376743 |
work_keys_str_mv | AT wagnercoreya postmenopausalbleedingduetoacu7intrauterinedeviceretainedforthirtyyears AT gimpelsonrichardj postmenopausalbleedingduetoacu7intrauterinedeviceretainedforthirtyyears |