Cargando…

Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study

BACKGROUND: Prosthetic hand users have to rely extensively on visual feedback, which seems to lead to a high conscious burden for the users, in order to manipulate their prosthetic devices. Indirect methods (electro-cutaneous, vibrotactile, auditory cues) have been used to convey information from th...

Descripción completa

Detalles Bibliográficos
Autores principales: Gonzalez, Jose, Soma, Hirokazu, Sekine, Masashi, Yu, Wenwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3481360/
https://www.ncbi.nlm.nih.gov/pubmed/22682425
http://dx.doi.org/10.1186/1743-0003-9-33
_version_ 1782247716366057472
author Gonzalez, Jose
Soma, Hirokazu
Sekine, Masashi
Yu, Wenwei
author_facet Gonzalez, Jose
Soma, Hirokazu
Sekine, Masashi
Yu, Wenwei
author_sort Gonzalez, Jose
collection PubMed
description BACKGROUND: Prosthetic hand users have to rely extensively on visual feedback, which seems to lead to a high conscious burden for the users, in order to manipulate their prosthetic devices. Indirect methods (electro-cutaneous, vibrotactile, auditory cues) have been used to convey information from the artificial limb to the amputee, but the usability and advantages of these feedback methods were explored mainly by looking at the performance results, not taking into account measurements of the user’s mental effort, attention, and emotions. The main objective of this study was to explore the feasibility of using psycho-physiological measurements to assess cognitive effort when manipulating a robot hand with and without the usage of a sensory substitution system based on auditory feedback, and how these psycho-physiological recordings relate to temporal and grasping performance in a static setting. METHODS: 10 male subjects (26+/-years old), participated in this study and were asked to come for 2 consecutive days. On the first day the experiment objective, tasks, and experiment setting was explained. Then, they completed a 30 minutes guided training. On the second day each subject was tested in 3 different modalities: Auditory Feedback only control (AF), Visual Feedback only control (VF), and Audiovisual Feedback control (AVF). For each modality they were asked to perform 10 trials. At the end of each test, the subject had to answer the NASA TLX questionnaire. Also, during the test the subject’s EEG, ECG, electro-dermal activity (EDA), and respiration rate were measured. RESULTS: The results show that a higher mental effort is needed when the subjects rely only on their vision, and that this effort seems to be reduced when auditory feedback is added to the human-machine interaction (multimodal feedback). Furthermore, better temporal performance and better grasping performance was obtained in the audiovisual modality. CONCLUSIONS: The performance improvements when using auditory cues, along with vision (multimodal feedback), can be attributed to a reduced attentional demand during the task, which can be attributed to a visual “pop-out” or enhance effect. Also, the NASA TLX, the EEG’s Alpha and Beta band, and the Heart Rate could be used to further evaluate sensory feedback systems in prosthetic applications.
format Online
Article
Text
id pubmed-3481360
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34813602012-10-27 Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study Gonzalez, Jose Soma, Hirokazu Sekine, Masashi Yu, Wenwei J Neuroeng Rehabil Research BACKGROUND: Prosthetic hand users have to rely extensively on visual feedback, which seems to lead to a high conscious burden for the users, in order to manipulate their prosthetic devices. Indirect methods (electro-cutaneous, vibrotactile, auditory cues) have been used to convey information from the artificial limb to the amputee, but the usability and advantages of these feedback methods were explored mainly by looking at the performance results, not taking into account measurements of the user’s mental effort, attention, and emotions. The main objective of this study was to explore the feasibility of using psycho-physiological measurements to assess cognitive effort when manipulating a robot hand with and without the usage of a sensory substitution system based on auditory feedback, and how these psycho-physiological recordings relate to temporal and grasping performance in a static setting. METHODS: 10 male subjects (26+/-years old), participated in this study and were asked to come for 2 consecutive days. On the first day the experiment objective, tasks, and experiment setting was explained. Then, they completed a 30 minutes guided training. On the second day each subject was tested in 3 different modalities: Auditory Feedback only control (AF), Visual Feedback only control (VF), and Audiovisual Feedback control (AVF). For each modality they were asked to perform 10 trials. At the end of each test, the subject had to answer the NASA TLX questionnaire. Also, during the test the subject’s EEG, ECG, electro-dermal activity (EDA), and respiration rate were measured. RESULTS: The results show that a higher mental effort is needed when the subjects rely only on their vision, and that this effort seems to be reduced when auditory feedback is added to the human-machine interaction (multimodal feedback). Furthermore, better temporal performance and better grasping performance was obtained in the audiovisual modality. CONCLUSIONS: The performance improvements when using auditory cues, along with vision (multimodal feedback), can be attributed to a reduced attentional demand during the task, which can be attributed to a visual “pop-out” or enhance effect. Also, the NASA TLX, the EEG’s Alpha and Beta band, and the Heart Rate could be used to further evaluate sensory feedback systems in prosthetic applications. BioMed Central 2012-06-09 /pmc/articles/PMC3481360/ /pubmed/22682425 http://dx.doi.org/10.1186/1743-0003-9-33 Text en Copyright ©2012 Gonzalez et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Gonzalez, Jose
Soma, Hirokazu
Sekine, Masashi
Yu, Wenwei
Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title_full Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title_fullStr Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title_full_unstemmed Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title_short Psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
title_sort psycho-physiological assessment of a prosthetic hand sensory feedback system based on an auditory display: a preliminary study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3481360/
https://www.ncbi.nlm.nih.gov/pubmed/22682425
http://dx.doi.org/10.1186/1743-0003-9-33
work_keys_str_mv AT gonzalezjose psychophysiologicalassessmentofaprosthetichandsensoryfeedbacksystembasedonanauditorydisplayapreliminarystudy
AT somahirokazu psychophysiologicalassessmentofaprosthetichandsensoryfeedbacksystembasedonanauditorydisplayapreliminarystudy
AT sekinemasashi psychophysiologicalassessmentofaprosthetichandsensoryfeedbacksystembasedonanauditorydisplayapreliminarystudy
AT yuwenwei psychophysiologicalassessmentofaprosthetichandsensoryfeedbacksystembasedonanauditorydisplayapreliminarystudy