Cargando…

Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes

BACKGROUND: The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiu, King-Wah, Tsai, Ming-Chao, Wu, Keng-Liang, Chiu, Yi-Chun, Lin, Ming-Tzung, Hu, Tsung-Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3482587/
https://www.ncbi.nlm.nih.gov/pubmed/22943739
http://dx.doi.org/10.1186/1471-230X-12-120
_version_ 1782247885652361216
author Chiu, King-Wah
Tsai, Ming-Chao
Wu, Keng-Liang
Chiu, Yi-Chun
Lin, Ming-Tzung
Hu, Tsung-Hui
author_facet Chiu, King-Wah
Tsai, Ming-Chao
Wu, Keng-Liang
Chiu, Yi-Chun
Lin, Ming-Tzung
Hu, Tsung-Hui
author_sort Chiu, King-Wah
collection PubMed
description BACKGROUND: The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. METHODS: We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. RESULTS: The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). CONCLUSIONS: Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not.
format Online
Article
Text
id pubmed-3482587
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34825872012-10-29 Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes Chiu, King-Wah Tsai, Ming-Chao Wu, Keng-Liang Chiu, Yi-Chun Lin, Ming-Tzung Hu, Tsung-Hui BMC Gastroenterol Research Article BACKGROUND: The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. METHODS: We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. RESULTS: The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). CONCLUSIONS: Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. BioMed Central 2012-09-03 /pmc/articles/PMC3482587/ /pubmed/22943739 http://dx.doi.org/10.1186/1471-230X-12-120 Text en Copyright ©2012 Chiu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chiu, King-Wah
Tsai, Ming-Chao
Wu, Keng-Liang
Chiu, Yi-Chun
Lin, Ming-Tzung
Hu, Tsung-Hui
Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title_full Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title_fullStr Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title_full_unstemmed Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title_short Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
title_sort surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3482587/
https://www.ncbi.nlm.nih.gov/pubmed/22943739
http://dx.doi.org/10.1186/1471-230X-12-120
work_keys_str_mv AT chiukingwah surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes
AT tsaimingchao surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes
AT wukengliang surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes
AT chiuyichun surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes
AT linmingtzung surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes
AT hutsunghui surveillanceculturesofsamplesobtainedfrombiopsychannelsandautomatedendoscopereprocessorsafterhighleveldisinfectionofgastrointestinalendoscopes