Cargando…
Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study
BACKGROUND: Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large hea...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483233/ https://www.ncbi.nlm.nih.gov/pubmed/23144694 http://dx.doi.org/10.1371/journal.pone.0045786 |
_version_ | 1782247971035807744 |
---|---|
author | Liu, Feng Chen, Zhefeng Gu, Yanqing Wang, Qing Cui, Weiding Fan, Weimin |
author_facet | Liu, Feng Chen, Zhefeng Gu, Yanqing Wang, Qing Cui, Weiding Fan, Weimin |
author_sort | Liu, Feng |
collection | PubMed |
description | BACKGROUND: Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. METHODS: Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. RESULTS: The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm(3)/MC and 0.89±0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS: This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE: This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care. |
format | Online Article Text |
id | pubmed-3483233 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-34832332012-11-09 Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study Liu, Feng Chen, Zhefeng Gu, Yanqing Wang, Qing Cui, Weiding Fan, Weimin PLoS One Research Article BACKGROUND: Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. METHODS: Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. RESULTS: The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78±8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65±0.29 mm(3)/MC and 0.89±0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS: This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE: This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care. Public Library of Science 2012-10-29 /pmc/articles/PMC3483233/ /pubmed/23144694 http://dx.doi.org/10.1371/journal.pone.0045786 Text en © 2012 Liu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Liu, Feng Chen, Zhefeng Gu, Yanqing Wang, Qing Cui, Weiding Fan, Weimin Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title | Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title_full | Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title_fullStr | Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title_full_unstemmed | Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title_short | Deformation of the Durom Acetabular Component and Its Impact on Tribology in a Cadaveric Model—A Simulator Study |
title_sort | deformation of the durom acetabular component and its impact on tribology in a cadaveric model—a simulator study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483233/ https://www.ncbi.nlm.nih.gov/pubmed/23144694 http://dx.doi.org/10.1371/journal.pone.0045786 |
work_keys_str_mv | AT liufeng deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy AT chenzhefeng deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy AT guyanqing deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy AT wangqing deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy AT cuiweiding deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy AT fanweimin deformationoftheduromacetabularcomponentanditsimpactontribologyinacadavericmodelasimulatorstudy |