Cargando…
Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic temp...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483845/ https://www.ncbi.nlm.nih.gov/pubmed/22843375 http://dx.doi.org/10.1093/jrr/rrs043 |
_version_ | 1782248073695592448 |
---|---|
author | Arimura, Hidetaka Itano, Wataru Shioyama, Yoshiyuki Matsushita, Norimasa Magome, Taiki Yoshitake, Tadamasa Anai, Shigeo Nakamura, Katsumasa Yoshidome, Satoshi Yamagami, Akihiko Honda, Hiroshi Ohki, Masafumi Toyofuku, Fukai Hirata, Hideki |
author_facet | Arimura, Hidetaka Itano, Wataru Shioyama, Yoshiyuki Matsushita, Norimasa Magome, Taiki Yoshitake, Tadamasa Anai, Shigeo Nakamura, Katsumasa Yoshidome, Satoshi Yamagami, Akihiko Honda, Hiroshi Ohki, Masafumi Toyofuku, Fukai Hirata, Hideki |
author_sort | Arimura, Hidetaka |
collection | PubMed |
description | We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic template image with a clinical target volume produced from a digitally reconstructed radiography (DRR) image of each patient. We evaluated the proposed method by calculating the residual error between the patient setup error obtained by the proposed method and the gold standard setup error determined by consensus between two radiation oncologists. Eleven training cases with prostate cancer were used for development of the proposed method, and then we applied the method to 10 test cases as a validation test. As a result, the residual errors in the anterior–posterior, superior–inferior and left–right directions were smaller than 2 mm for the validation test. The mean residual error was 2.65 ± 1.21 mm in the Euclidean distance for training cases, and 3.10 ± 1.49 mm for the validation test. There was no statistically significant difference in the residual error between the test for training cases and the validation test (P = 0.438). The proposed method appears to be robust for detecting patient setup error in the treatment of prostate cancer radiotherapy. |
format | Online Article Text |
id | pubmed-3483845 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34838452012-10-30 Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy Arimura, Hidetaka Itano, Wataru Shioyama, Yoshiyuki Matsushita, Norimasa Magome, Taiki Yoshitake, Tadamasa Anai, Shigeo Nakamura, Katsumasa Yoshidome, Satoshi Yamagami, Akihiko Honda, Hiroshi Ohki, Masafumi Toyofuku, Fukai Hirata, Hideki J Radiat Res Technology We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic template image with a clinical target volume produced from a digitally reconstructed radiography (DRR) image of each patient. We evaluated the proposed method by calculating the residual error between the patient setup error obtained by the proposed method and the gold standard setup error determined by consensus between two radiation oncologists. Eleven training cases with prostate cancer were used for development of the proposed method, and then we applied the method to 10 test cases as a validation test. As a result, the residual errors in the anterior–posterior, superior–inferior and left–right directions were smaller than 2 mm for the validation test. The mean residual error was 2.65 ± 1.21 mm in the Euclidean distance for training cases, and 3.10 ± 1.49 mm for the validation test. There was no statistically significant difference in the residual error between the test for training cases and the validation test (P = 0.438). The proposed method appears to be robust for detecting patient setup error in the treatment of prostate cancer radiotherapy. Oxford University Press 2012-11 2012-07-26 /pmc/articles/PMC3483845/ /pubmed/22843375 http://dx.doi.org/10.1093/jrr/rrs043 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technology Arimura, Hidetaka Itano, Wataru Shioyama, Yoshiyuki Matsushita, Norimasa Magome, Taiki Yoshitake, Tadamasa Anai, Shigeo Nakamura, Katsumasa Yoshidome, Satoshi Yamagami, Akihiko Honda, Hiroshi Ohki, Masafumi Toyofuku, Fukai Hirata, Hideki Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title | Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title_full | Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title_fullStr | Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title_full_unstemmed | Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title_short | Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
title_sort | computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483845/ https://www.ncbi.nlm.nih.gov/pubmed/22843375 http://dx.doi.org/10.1093/jrr/rrs043 |
work_keys_str_mv | AT arimurahidetaka computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT itanowataru computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT shioyamayoshiyuki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT matsushitanorimasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT magometaiki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT yoshitaketadamasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT anaishigeo computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT nakamurakatsumasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT yoshidomesatoshi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT yamagamiakihiko computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT hondahiroshi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT ohkimasafumi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT toyofukufukai computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy AT hiratahideki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy |