Cargando…

Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy

We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic temp...

Descripción completa

Detalles Bibliográficos
Autores principales: Arimura, Hidetaka, Itano, Wataru, Shioyama, Yoshiyuki, Matsushita, Norimasa, Magome, Taiki, Yoshitake, Tadamasa, Anai, Shigeo, Nakamura, Katsumasa, Yoshidome, Satoshi, Yamagami, Akihiko, Honda, Hiroshi, Ohki, Masafumi, Toyofuku, Fukai, Hirata, Hideki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483845/
https://www.ncbi.nlm.nih.gov/pubmed/22843375
http://dx.doi.org/10.1093/jrr/rrs043
_version_ 1782248073695592448
author Arimura, Hidetaka
Itano, Wataru
Shioyama, Yoshiyuki
Matsushita, Norimasa
Magome, Taiki
Yoshitake, Tadamasa
Anai, Shigeo
Nakamura, Katsumasa
Yoshidome, Satoshi
Yamagami, Akihiko
Honda, Hiroshi
Ohki, Masafumi
Toyofuku, Fukai
Hirata, Hideki
author_facet Arimura, Hidetaka
Itano, Wataru
Shioyama, Yoshiyuki
Matsushita, Norimasa
Magome, Taiki
Yoshitake, Tadamasa
Anai, Shigeo
Nakamura, Katsumasa
Yoshidome, Satoshi
Yamagami, Akihiko
Honda, Hiroshi
Ohki, Masafumi
Toyofuku, Fukai
Hirata, Hideki
author_sort Arimura, Hidetaka
collection PubMed
description We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic template image with a clinical target volume produced from a digitally reconstructed radiography (DRR) image of each patient. We evaluated the proposed method by calculating the residual error between the patient setup error obtained by the proposed method and the gold standard setup error determined by consensus between two radiation oncologists. Eleven training cases with prostate cancer were used for development of the proposed method, and then we applied the method to 10 test cases as a validation test. As a result, the residual errors in the anterior–posterior, superior–inferior and left–right directions were smaller than 2 mm for the validation test. The mean residual error was 2.65 ± 1.21 mm in the Euclidean distance for training cases, and 3.10 ± 1.49 mm for the validation test. There was no statistically significant difference in the residual error between the test for training cases and the validation test (P = 0.438). The proposed method appears to be robust for detecting patient setup error in the treatment of prostate cancer radiotherapy.
format Online
Article
Text
id pubmed-3483845
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-34838452012-10-30 Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy Arimura, Hidetaka Itano, Wataru Shioyama, Yoshiyuki Matsushita, Norimasa Magome, Taiki Yoshitake, Tadamasa Anai, Shigeo Nakamura, Katsumasa Yoshidome, Satoshi Yamagami, Akihiko Honda, Hiroshi Ohki, Masafumi Toyofuku, Fukai Hirata, Hideki J Radiat Res Technology We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic template image with a clinical target volume produced from a digitally reconstructed radiography (DRR) image of each patient. We evaluated the proposed method by calculating the residual error between the patient setup error obtained by the proposed method and the gold standard setup error determined by consensus between two radiation oncologists. Eleven training cases with prostate cancer were used for development of the proposed method, and then we applied the method to 10 test cases as a validation test. As a result, the residual errors in the anterior–posterior, superior–inferior and left–right directions were smaller than 2 mm for the validation test. The mean residual error was 2.65 ± 1.21 mm in the Euclidean distance for training cases, and 3.10 ± 1.49 mm for the validation test. There was no statistically significant difference in the residual error between the test for training cases and the validation test (P = 0.438). The proposed method appears to be robust for detecting patient setup error in the treatment of prostate cancer radiotherapy. Oxford University Press 2012-11 2012-07-26 /pmc/articles/PMC3483845/ /pubmed/22843375 http://dx.doi.org/10.1093/jrr/rrs043 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technology
Arimura, Hidetaka
Itano, Wataru
Shioyama, Yoshiyuki
Matsushita, Norimasa
Magome, Taiki
Yoshitake, Tadamasa
Anai, Shigeo
Nakamura, Katsumasa
Yoshidome, Satoshi
Yamagami, Akihiko
Honda, Hiroshi
Ohki, Masafumi
Toyofuku, Fukai
Hirata, Hideki
Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title_full Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title_fullStr Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title_full_unstemmed Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title_short Computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
title_sort computerized estimation of patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy
topic Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483845/
https://www.ncbi.nlm.nih.gov/pubmed/22843375
http://dx.doi.org/10.1093/jrr/rrs043
work_keys_str_mv AT arimurahidetaka computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT itanowataru computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT shioyamayoshiyuki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT matsushitanorimasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT magometaiki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT yoshitaketadamasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT anaishigeo computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT nakamurakatsumasa computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT yoshidomesatoshi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT yamagamiakihiko computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT hondahiroshi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT ohkimasafumi computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT toyofukufukai computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy
AT hiratahideki computerizedestimationofpatientsetuperrorsinportalimagesbasedonlocalizedpelvictemplatesforprostatecancerradiotherapy