Cargando…
Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even thoug...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483851/ https://www.ncbi.nlm.nih.gov/pubmed/22915780 http://dx.doi.org/10.1093/jrr/rrs050 |
_version_ | 1782248075102781440 |
---|---|
author | Chu, Kuang Hua Lin, Yu Ting Hsu, Chia Chun Chen, Chien Yi Pan, Lung Kwang |
author_facet | Chu, Kuang Hua Lin, Yu Ting Hsu, Chia Chun Chen, Chien Yi Pan, Lung Kwang |
author_sort | Chu, Kuang Hua |
collection | PubMed |
description | This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. |
format | Online Article Text |
id | pubmed-3483851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34838512012-10-30 Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model Chu, Kuang Hua Lin, Yu Ting Hsu, Chia Chun Chen, Chien Yi Pan, Lung Kwang J Radiat Res Technology This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. Oxford University Press 2012-11 2012-08-21 /pmc/articles/PMC3483851/ /pubmed/22915780 http://dx.doi.org/10.1093/jrr/rrs050 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technology Chu, Kuang Hua Lin, Yu Ting Hsu, Chia Chun Chen, Chien Yi Pan, Lung Kwang Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title | Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title_full | Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title_fullStr | Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title_full_unstemmed | Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title_short | Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model |
title_sort | evaluation of effective dose for a patient under ga-67 nuclear examination using tld, water phantom and a simplified model |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483851/ https://www.ncbi.nlm.nih.gov/pubmed/22915780 http://dx.doi.org/10.1093/jrr/rrs050 |
work_keys_str_mv | AT chukuanghua evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel AT linyuting evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel AT hsuchiachun evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel AT chenchienyi evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel AT panlungkwang evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel |