Cargando…

Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model

This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even thoug...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Kuang Hua, Lin, Yu Ting, Hsu, Chia Chun, Chen, Chien Yi, Pan, Lung Kwang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483851/
https://www.ncbi.nlm.nih.gov/pubmed/22915780
http://dx.doi.org/10.1093/jrr/rrs050
_version_ 1782248075102781440
author Chu, Kuang Hua
Lin, Yu Ting
Hsu, Chia Chun
Chen, Chien Yi
Pan, Lung Kwang
author_facet Chu, Kuang Hua
Lin, Yu Ting
Hsu, Chia Chun
Chen, Chien Yi
Pan, Lung Kwang
author_sort Chu, Kuang Hua
collection PubMed
description This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility.
format Online
Article
Text
id pubmed-3483851
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-34838512012-10-30 Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model Chu, Kuang Hua Lin, Yu Ting Hsu, Chia Chun Chen, Chien Yi Pan, Lung Kwang J Radiat Res Technology This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. Oxford University Press 2012-11 2012-08-21 /pmc/articles/PMC3483851/ /pubmed/22915780 http://dx.doi.org/10.1093/jrr/rrs050 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technology
Chu, Kuang Hua
Lin, Yu Ting
Hsu, Chia Chun
Chen, Chien Yi
Pan, Lung Kwang
Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title_full Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title_fullStr Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title_full_unstemmed Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title_short Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model
title_sort evaluation of effective dose for a patient under ga-67 nuclear examination using tld, water phantom and a simplified model
topic Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483851/
https://www.ncbi.nlm.nih.gov/pubmed/22915780
http://dx.doi.org/10.1093/jrr/rrs050
work_keys_str_mv AT chukuanghua evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel
AT linyuting evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel
AT hsuchiachun evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel
AT chenchienyi evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel
AT panlungkwang evaluationofeffectivedoseforapatientunderga67nuclearexaminationusingtldwaterphantomandasimplifiedmodel