Cargando…

Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

OBJECTIVE: To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. MATERIALS AND METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Juan, Sun, Gang, Lu, Yang, Yu, Bing-bing, Li, Min, Li, Li, Li, Guo-ying, Peng, Zhao-hui, Zhang, Xu-Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3484286/
https://www.ncbi.nlm.nih.gov/pubmed/23118564
http://dx.doi.org/10.3348/kjr.2012.13.6.667
_version_ 1782248125658824704
author Ding, Juan
Sun, Gang
Lu, Yang
Yu, Bing-bing
Li, Min
Li, Li
Li, Guo-ying
Peng, Zhao-hui
Zhang, Xu-Ping
author_facet Ding, Juan
Sun, Gang
Lu, Yang
Yu, Bing-bing
Li, Min
Li, Li
Li, Guo-ying
Peng, Zhao-hui
Zhang, Xu-Ping
author_sort Ding, Juan
collection PubMed
description OBJECTIVE: To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. MATERIALS AND METHODS: From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. RESULTS: The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 ± 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 ± 0.01 mSv) (p < 0.001). CONCLUSION: 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.
format Online
Article
Text
id pubmed-3484286
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-34842862012-11-02 Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences Ding, Juan Sun, Gang Lu, Yang Yu, Bing-bing Li, Min Li, Li Li, Guo-ying Peng, Zhao-hui Zhang, Xu-Ping Korean J Radiol Original Article OBJECTIVE: To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. MATERIALS AND METHODS: From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. RESULTS: The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 ± 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 ± 0.01 mSv) (p < 0.001). CONCLUSION: 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases. The Korean Society of Radiology 2012 2012-10-12 /pmc/articles/PMC3484286/ /pubmed/23118564 http://dx.doi.org/10.3348/kjr.2012.13.6.667 Text en Copyright © 2012 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ding, Juan
Sun, Gang
Lu, Yang
Yu, Bing-bing
Li, Min
Li, Li
Li, Guo-ying
Peng, Zhao-hui
Zhang, Xu-Ping
Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title_full Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title_fullStr Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title_full_unstemmed Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title_short Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences
title_sort evaluation of anterior ethmoidal artery by 320-slice ct angiography with comparison to three-dimensional spin digital subtraction angiography: initial experiences
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3484286/
https://www.ncbi.nlm.nih.gov/pubmed/23118564
http://dx.doi.org/10.3348/kjr.2012.13.6.667
work_keys_str_mv AT dingjuan evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT sungang evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT luyang evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT yubingbing evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT limin evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT lili evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT liguoying evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT pengzhaohui evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences
AT zhangxuping evaluationofanteriorethmoidalarteryby320slicectangiographywithcomparisontothreedimensionalspindigitalsubtractionangiographyinitialexperiences