A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model

INTRODUCTION: This study was designed to quantitatively evaluate the sealing effect of a polyvinyl chloride tapered endotracheal tube cuff and to compare the tapered cuff with cylindrical endotracheal tube cuffs using an in vitro viscous fluid model. METHODS: Five types of 8.0 mm inner diameter endo...

Descripción completa

Detalles Bibliográficos
Autores principales: Shiotsuka, J, Lefor, A T, Sanui, M, Nagata, O, Horiguchi, A, Sasabuchi, Y
Formato: Online Artículo Texto
Lenguaje:English
Publicado: EDIMES Edizioni Internazionali Srl 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485387/
https://www.ncbi.nlm.nih.gov/pubmed/23439857
_version_ 1782248298637164544
author Shiotsuka, J
Lefor, A T
Sanui, M
Nagata, O
Horiguchi, A
Sasabuchi, Y
author_facet Shiotsuka, J
Lefor, A T
Sanui, M
Nagata, O
Horiguchi, A
Sasabuchi, Y
author_sort Shiotsuka, J
collection PubMed
description INTRODUCTION: This study was designed to quantitatively evaluate the sealing effect of a polyvinyl chloride tapered endotracheal tube cuff and to compare the tapered cuff with cylindrical endotracheal tube cuffs using an in vitro viscous fluid model. METHODS: Five types of 8.0 mm inner diameter endotracheal tubes (TaperGuard, PortexSacett, PortexSoftseal, Sheridan HVT, Sheridan CF) were fixed in vertically placed 20mm internal diameter acrylic tubes. The cuffs were inflated to 25 mmHg pressure and water was added to the top of the cuff. The amount of water leaking around the cuff at five minutes was measured. Afterwards a viscous fluid was poured above the cuff and the amount of fluid passing around the cuff at five minutes and four hours was measured. Each determination was repeated five times and the data analyzed. RESULTS: The median (range) amount (ml) of dyed water passing around the cuff at 5 minutes was TaperGuard tube 0 (0-0.2), PortexSacett 81.1 (44.6-107.9), PortexSoftseal 95.4 (91.4-113.7), Sheridan HVT 46.5 (32.7-74.6) and Sheridan CF 52.6 (31.9-62.2), suggesting that TaperGuard significantly (P<0.05) reduced fluid leakage. The viscous fluid leakage at 5 minutes was not significantly different among the groups while the amount of leaked viscous fluid at 4 hours was 0.2 (0-1.1) for the TaperGuard, 57.6 (11.9-117.4) for the PortexSacett, 23.2 (13.8-33.0) for the PortexSoftseal, 5.5 (2.7-15.4) for the Sheridan HVT and 5.6 (1.8-7.9) for the Sheridan CF. CONCLUSION: An endotracheal tube with a tapered polyvinyl chloride cuff had significantly less fluid leakage compared to four tubes with cylindrical cuffs.
format Online
Article
Text
id pubmed-3485387
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher EDIMES Edizioni Internazionali Srl
record_format MEDLINE/PubMed
spelling pubmed-34853872013-02-25 A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model Shiotsuka, J Lefor, A T Sanui, M Nagata, O Horiguchi, A Sasabuchi, Y HSR Proc Intensive Care Cardiovasc Anesth Research-Article INTRODUCTION: This study was designed to quantitatively evaluate the sealing effect of a polyvinyl chloride tapered endotracheal tube cuff and to compare the tapered cuff with cylindrical endotracheal tube cuffs using an in vitro viscous fluid model. METHODS: Five types of 8.0 mm inner diameter endotracheal tubes (TaperGuard, PortexSacett, PortexSoftseal, Sheridan HVT, Sheridan CF) were fixed in vertically placed 20mm internal diameter acrylic tubes. The cuffs were inflated to 25 mmHg pressure and water was added to the top of the cuff. The amount of water leaking around the cuff at five minutes was measured. Afterwards a viscous fluid was poured above the cuff and the amount of fluid passing around the cuff at five minutes and four hours was measured. Each determination was repeated five times and the data analyzed. RESULTS: The median (range) amount (ml) of dyed water passing around the cuff at 5 minutes was TaperGuard tube 0 (0-0.2), PortexSacett 81.1 (44.6-107.9), PortexSoftseal 95.4 (91.4-113.7), Sheridan HVT 46.5 (32.7-74.6) and Sheridan CF 52.6 (31.9-62.2), suggesting that TaperGuard significantly (P<0.05) reduced fluid leakage. The viscous fluid leakage at 5 minutes was not significantly different among the groups while the amount of leaked viscous fluid at 4 hours was 0.2 (0-1.1) for the TaperGuard, 57.6 (11.9-117.4) for the PortexSacett, 23.2 (13.8-33.0) for the PortexSoftseal, 5.5 (2.7-15.4) for the Sheridan HVT and 5.6 (1.8-7.9) for the Sheridan CF. CONCLUSION: An endotracheal tube with a tapered polyvinyl chloride cuff had significantly less fluid leakage compared to four tubes with cylindrical cuffs. EDIMES Edizioni Internazionali Srl 2012 /pmc/articles/PMC3485387/ /pubmed/23439857 Text en Copyright © 2012, HSR Proceedings in Intensive Care and Cardiovascular Anesthesia http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License 3.0, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/3.0/ and http://creativecommons.org/licenses/by-nc/3.0/legalcode.
spellingShingle Research-Article
Shiotsuka, J
Lefor, A T
Sanui, M
Nagata, O
Horiguchi, A
Sasabuchi, Y
A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title_full A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title_fullStr A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title_full_unstemmed A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title_short A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
title_sort quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
topic Research-Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485387/
https://www.ncbi.nlm.nih.gov/pubmed/23439857
work_keys_str_mv AT shiotsukaj aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT leforat aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT sanuim aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT nagatao aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT horiguchia aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT sasabuchiy aquantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT shiotsukaj quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT leforat quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT sanuim quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT nagatao quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT horiguchia quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel
AT sasabuchiy quantitativeevaluationoffluidleakagearoundapolyvinylchloridetaperedendotrachealtubecuffusinganinvitromodel