Cargando…

A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy

A novel method to assess left ventricular (LV) mechanical dyssynchrony using three-dimensional echocardiography (3DE) and semi-automated border detection was investigated, which might be superior in prediction of response to cardiac resynchronisation therapy (CRT) compared to traditional measures th...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Heide, J. A., Aly, M. F. A., Kleijn, S. A., van Dijk, J., Kamp, O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485531/
https://www.ncbi.nlm.nih.gov/pubmed/22302648
http://dx.doi.org/10.1007/s10554-012-0019-3
_version_ 1782248314317570048
author van der Heide, J. A.
Aly, M. F. A.
Kleijn, S. A.
van Dijk, J.
Kamp, O.
author_facet van der Heide, J. A.
Aly, M. F. A.
Kleijn, S. A.
van Dijk, J.
Kamp, O.
author_sort van der Heide, J. A.
collection PubMed
description A novel method to assess left ventricular (LV) mechanical dyssynchrony using three-dimensional echocardiography (3DE) and semi-automated border detection was investigated, which might be superior in prediction of response to cardiac resynchronisation therapy (CRT) compared to traditional measures that rely solely on segmental time-to-contraction. Twenty-eight heart failure patients underwent real-time 3DE before CRT and at 6–12 months follow-up. Analysis of 3DE was performed using TomTec Research-Arena software featuring semi-automated endocardial border detection. The following echocardiographic parameters were calculated in a 16-segment model: areas under segmental time-volume-curves (STV); delay between contraction of the earliest and latest segment (L-E); and standard deviation of segmental time-to-contraction (SDI). Response to CRT was defined as ≥10% decrease in LV end-systolic volume at follow-up. Baseline Pre-STV had a higher sensitivity than SDI for prediction of response (94 vs 67%, respectively), with equal specificity (78%) and a higher area under receiver operator characteristic curve. In contrast, L-E had a sensitivity of 83% and a specificity of 56%. Using 3DE, methods that combine segmental time-to-contraction with segmental contractility might improve LV dyssynchrony assessment compared to traditional methods based on segmental time-to-contraction alone. Pre-STV might be a better predictor of response to CRT than SDI.
format Online
Article
Text
id pubmed-3485531
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-34855312012-11-05 A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy van der Heide, J. A. Aly, M. F. A. Kleijn, S. A. van Dijk, J. Kamp, O. Int J Cardiovasc Imaging Original Paper A novel method to assess left ventricular (LV) mechanical dyssynchrony using three-dimensional echocardiography (3DE) and semi-automated border detection was investigated, which might be superior in prediction of response to cardiac resynchronisation therapy (CRT) compared to traditional measures that rely solely on segmental time-to-contraction. Twenty-eight heart failure patients underwent real-time 3DE before CRT and at 6–12 months follow-up. Analysis of 3DE was performed using TomTec Research-Arena software featuring semi-automated endocardial border detection. The following echocardiographic parameters were calculated in a 16-segment model: areas under segmental time-volume-curves (STV); delay between contraction of the earliest and latest segment (L-E); and standard deviation of segmental time-to-contraction (SDI). Response to CRT was defined as ≥10% decrease in LV end-systolic volume at follow-up. Baseline Pre-STV had a higher sensitivity than SDI for prediction of response (94 vs 67%, respectively), with equal specificity (78%) and a higher area under receiver operator characteristic curve. In contrast, L-E had a sensitivity of 83% and a specificity of 56%. Using 3DE, methods that combine segmental time-to-contraction with segmental contractility might improve LV dyssynchrony assessment compared to traditional methods based on segmental time-to-contraction alone. Pre-STV might be a better predictor of response to CRT than SDI. Springer Netherlands 2012-02-03 2012 /pmc/articles/PMC3485531/ /pubmed/22302648 http://dx.doi.org/10.1007/s10554-012-0019-3 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Paper
van der Heide, J. A.
Aly, M. F. A.
Kleijn, S. A.
van Dijk, J.
Kamp, O.
A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title_full A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title_fullStr A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title_full_unstemmed A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title_short A new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
title_sort new quantification method for mechanical dyssynchrony with three-dimensional echocardiography; segmental time and volume loss for prediction of response to cardiac resynchronisation therapy
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485531/
https://www.ncbi.nlm.nih.gov/pubmed/22302648
http://dx.doi.org/10.1007/s10554-012-0019-3
work_keys_str_mv AT vanderheideja anewquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT alymfa anewquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT kleijnsa anewquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT vandijkj anewquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT kampo anewquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT vanderheideja newquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT alymfa newquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT kleijnsa newquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT vandijkj newquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy
AT kampo newquantificationmethodformechanicaldyssynchronywiththreedimensionalechocardiographysegmentaltimeandvolumelossforpredictionofresponsetocardiacresynchronisationtherapy