Cargando…

Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells

BACKGROUND: The reticulocyte count is a good marker of erythropoietic activity of the bone marrow. In the mid-1990s, automated flow cytometric analysis replaced microscopy for the quantification of reticulocytes. Leukocytosis cases with an erroneously high reticulocyte count and a high immature reti...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Ahhyun, Park, Joonhong, Kim, Myungshin, Lim, Jihyang, Oh, Eun-Jee, Kim, Yonggoo, Park, Yeon-Joon, Han, Kyungja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3486932/
https://www.ncbi.nlm.nih.gov/pubmed/23130337
http://dx.doi.org/10.3343/alm.2012.32.6.392
_version_ 1782248417929461760
author Kim, Ahhyun
Park, Joonhong
Kim, Myungshin
Lim, Jihyang
Oh, Eun-Jee
Kim, Yonggoo
Park, Yeon-Joon
Han, Kyungja
author_facet Kim, Ahhyun
Park, Joonhong
Kim, Myungshin
Lim, Jihyang
Oh, Eun-Jee
Kim, Yonggoo
Park, Yeon-Joon
Han, Kyungja
author_sort Kim, Ahhyun
collection PubMed
description BACKGROUND: The reticulocyte count is a good marker of erythropoietic activity of the bone marrow. In the mid-1990s, automated flow cytometric analysis replaced microscopy for the quantification of reticulocytes. Leukocytosis cases with an erroneously high reticulocyte count and a high immature reticulocyte fraction (IRF) have been reported. In this study, we analyzed reticulocyte counts in leukocytosis samples, in an effort to identify a correction method. METHODS: The study comprised of 21 samples from 16 leukocytosis patients. Results of reticulocyte analyses obtained using a XE-2100 hematology analyzer (Sysmex, Japan) were compared with those obtained using the supravital staining technique, which is a reference method. If the samples showed erroneously high reticulocyte counts and IRF, they were reanalyzed after serial dilution with isotonic solution. RESULTS: Five samples from 4 patients showed erroneously elevated reticulocyte counts and/or IRF on the XE-2100 analyzer. They displayed abnormal reticulocyte scattergrams, with 4 of 5 cases indicated by a flag. The white blood cell (WBC) fractions overlapped with the reticulocyte regions, especially with the IRF. Diagnoses and blast counts were variable when such errors occurred; WBC counts varied from 218.19×10(9)/L to 725.14×10(9)/L. The errors were corrected by simple dilution with isotonic solution. However, the corrective WBC counts differed according to individual cases. CONCLUSIONS: When leukocytosis samples exhibit an abnormal reticulocyte scattergram with a flag, or an abnormally high IRF, we recommend the dilution of the sample with isotonic solution to a WBC count of about 100.00×10(9)/L, followed by reanalysis of the reticulocyte count and reticulocyte scattergram.
format Online
Article
Text
id pubmed-3486932
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-34869322012-11-05 Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells Kim, Ahhyun Park, Joonhong Kim, Myungshin Lim, Jihyang Oh, Eun-Jee Kim, Yonggoo Park, Yeon-Joon Han, Kyungja Ann Lab Med Original Article BACKGROUND: The reticulocyte count is a good marker of erythropoietic activity of the bone marrow. In the mid-1990s, automated flow cytometric analysis replaced microscopy for the quantification of reticulocytes. Leukocytosis cases with an erroneously high reticulocyte count and a high immature reticulocyte fraction (IRF) have been reported. In this study, we analyzed reticulocyte counts in leukocytosis samples, in an effort to identify a correction method. METHODS: The study comprised of 21 samples from 16 leukocytosis patients. Results of reticulocyte analyses obtained using a XE-2100 hematology analyzer (Sysmex, Japan) were compared with those obtained using the supravital staining technique, which is a reference method. If the samples showed erroneously high reticulocyte counts and IRF, they were reanalyzed after serial dilution with isotonic solution. RESULTS: Five samples from 4 patients showed erroneously elevated reticulocyte counts and/or IRF on the XE-2100 analyzer. They displayed abnormal reticulocyte scattergrams, with 4 of 5 cases indicated by a flag. The white blood cell (WBC) fractions overlapped with the reticulocyte regions, especially with the IRF. Diagnoses and blast counts were variable when such errors occurred; WBC counts varied from 218.19×10(9)/L to 725.14×10(9)/L. The errors were corrected by simple dilution with isotonic solution. However, the corrective WBC counts differed according to individual cases. CONCLUSIONS: When leukocytosis samples exhibit an abnormal reticulocyte scattergram with a flag, or an abnormally high IRF, we recommend the dilution of the sample with isotonic solution to a WBC count of about 100.00×10(9)/L, followed by reanalysis of the reticulocyte count and reticulocyte scattergram. The Korean Society for Laboratory Medicine 2012-11 2012-10-17 /pmc/articles/PMC3486932/ /pubmed/23130337 http://dx.doi.org/10.3343/alm.2012.32.6.392 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Ahhyun
Park, Joonhong
Kim, Myungshin
Lim, Jihyang
Oh, Eun-Jee
Kim, Yonggoo
Park, Yeon-Joon
Han, Kyungja
Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title_full Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title_fullStr Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title_full_unstemmed Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title_short Correction of Pseudoreticulocytosis in Leukocytosis Samples Using the Sysmex XE-2100 Analyzer Depends on the Type and Number of White Blood Cells
title_sort correction of pseudoreticulocytosis in leukocytosis samples using the sysmex xe-2100 analyzer depends on the type and number of white blood cells
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3486932/
https://www.ncbi.nlm.nih.gov/pubmed/23130337
http://dx.doi.org/10.3343/alm.2012.32.6.392
work_keys_str_mv AT kimahhyun correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT parkjoonhong correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT kimmyungshin correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT limjihyang correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT oheunjee correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT kimyonggoo correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT parkyeonjoon correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells
AT hankyungja correctionofpseudoreticulocytosisinleukocytosissamplesusingthesysmexxe2100analyzerdependsonthetypeandnumberofwhitebloodcells