Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients

BACKGROUND AND PURPOSE: Although a tourniquet may reduce bleeding during total knee replacement (TKA), and thereby possibly improve fixation, it might also cause complications. Migration as measured by radiostereometric analysis (RSA) can predict future loosening. We investigated whether the use of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ledin, Håkan, Aspenberg, Per, Good, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3488177/
https://www.ncbi.nlm.nih.gov/pubmed/22974220
http://dx.doi.org/10.3109/17453674.2012.727078
_version_ 1782248576279117824
author Ledin, Håkan
Aspenberg, Per
Good, Lars
author_facet Ledin, Håkan
Aspenberg, Per
Good, Lars
author_sort Ledin, Håkan
collection PubMed
description BACKGROUND AND PURPOSE: Although a tourniquet may reduce bleeding during total knee replacement (TKA), and thereby possibly improve fixation, it might also cause complications. Migration as measured by radiostereometric analysis (RSA) can predict future loosening. We investigated whether the use of a tourniquet influences prosthesis fixation measured with RSA. This has not been investigated previously to our knowledge. METHODS: 50 patients with osteoarthritis of the knee were randomized to cemented TKA with or without tourniquet. RSA was performed postoperatively and at 6 months, 1 year, and 2 years. Pain during hospital stay was registered with a visual analog scale (VAS) and morphine consumption was measured. Overt bleeding and blood transfusions were registered, and total bleeding was estimated by the hemoglobin dilution method. Range of motion was measured up to 2 years. RESULTS: RSA maximal total point motion (MTPM) differed by 0.01 mm (95% CI –0.13 to 0.15). Patients in the tourniquet group had less overt bleeding (317 mL vs. 615 mL), but the total bleeding estimated by hemoglobin dilution at day 4 was only slightly less (1,184 mL vs. 1,236 mL) with a mean difference of –54 mL (95% CI –256 to 152). Pain VAS measurements were lower in the non-tourniquet group (p = 0.01). There was no significant difference in morphine consumption. Range of motion was 11° more in the non-tourniquet group (p = 0.001 at 2 years). INTERPRETATION: Tourniquet use did not improve fixation but it may cause more postoperative pain and less range of motion.
format Online
Article
Text
id pubmed-3488177
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-34881772012-11-05 Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients Ledin, Håkan Aspenberg, Per Good, Lars Acta Orthop Knee BACKGROUND AND PURPOSE: Although a tourniquet may reduce bleeding during total knee replacement (TKA), and thereby possibly improve fixation, it might also cause complications. Migration as measured by radiostereometric analysis (RSA) can predict future loosening. We investigated whether the use of a tourniquet influences prosthesis fixation measured with RSA. This has not been investigated previously to our knowledge. METHODS: 50 patients with osteoarthritis of the knee were randomized to cemented TKA with or without tourniquet. RSA was performed postoperatively and at 6 months, 1 year, and 2 years. Pain during hospital stay was registered with a visual analog scale (VAS) and morphine consumption was measured. Overt bleeding and blood transfusions were registered, and total bleeding was estimated by the hemoglobin dilution method. Range of motion was measured up to 2 years. RESULTS: RSA maximal total point motion (MTPM) differed by 0.01 mm (95% CI –0.13 to 0.15). Patients in the tourniquet group had less overt bleeding (317 mL vs. 615 mL), but the total bleeding estimated by hemoglobin dilution at day 4 was only slightly less (1,184 mL vs. 1,236 mL) with a mean difference of –54 mL (95% CI –256 to 152). Pain VAS measurements were lower in the non-tourniquet group (p = 0.01). There was no significant difference in morphine consumption. Range of motion was 11° more in the non-tourniquet group (p = 0.001 at 2 years). INTERPRETATION: Tourniquet use did not improve fixation but it may cause more postoperative pain and less range of motion. Informa Healthcare 2012-10 2012-10-22 /pmc/articles/PMC3488177/ /pubmed/22974220 http://dx.doi.org/10.3109/17453674.2012.727078 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Knee
Ledin, Håkan
Aspenberg, Per
Good, Lars
Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title_full Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title_fullStr Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title_full_unstemmed Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title_short Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: A randomized RSA study involving 50 patients
title_sort tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion: a randomized rsa study involving 50 patients
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3488177/
https://www.ncbi.nlm.nih.gov/pubmed/22974220
http://dx.doi.org/10.3109/17453674.2012.727078
work_keys_str_mv AT ledinhakan tourniquetuseintotalkneereplacementdoesnotimprovefixationbutappearstoreducefinalrangeofmotionarandomizedrsastudyinvolving50patients
AT aspenbergper tourniquetuseintotalkneereplacementdoesnotimprovefixationbutappearstoreducefinalrangeofmotionarandomizedrsastudyinvolving50patients
AT goodlars tourniquetuseintotalkneereplacementdoesnotimprovefixationbutappearstoreducefinalrangeofmotionarandomizedrsastudyinvolving50patients