OBJECTIVES: To determine the level of agreement between a ‘conventional’ Ankle-Brachial Index (ABI) measurement (using Doppler and mercury sphygmomanometer taken by a research nurse) and a ‘pragmatic’ ABI measure (using an oscillometric device taken by a practice nurse) in primary care. To ascertain...

Descripción completa

Detalles Bibliográficos
Autores principales: Nelson, Mark R, Quinn, Stephen, Winzenberg, Tania M, Howes, Faline, Shiel, Louise, Reid, Christopher M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3488728/
https://www.ncbi.nlm.nih.gov/pubmed/23100446
http://dx.doi.org/10.1136/bmjopen-2012-001689
_version_ 1782248668144861184
author Nelson, Mark R
Quinn, Stephen
Winzenberg, Tania M
Howes, Faline
Shiel, Louise
Reid, Christopher M
author_facet Nelson, Mark R
Quinn, Stephen
Winzenberg, Tania M
Howes, Faline
Shiel, Louise
Reid, Christopher M
author_sort Nelson, Mark R
collection PubMed
description OBJECTIVES: To determine the level of agreement between a ‘conventional’ Ankle-Brachial Index (ABI) measurement (using Doppler and mercury sphygmomanometer taken by a research nurse) and a ‘pragmatic’ ABI measure (using an oscillometric device taken by a practice nurse) in primary care. To ascertain the utility of a pragmatic ABI measure for the diagnosis of peripheral arterial disease (PAD) in primary care. DESIGN: Cross-sectional validation and diagnostic accuracy study. Descriptive analyses were used to investigate the agreement between the two procedures using the Bland and Altman method to determine whether the correlation between ABI readings varied systematically. Diagnostic accuracy was assessed via sensitivity, specificity, accuracy, likelihood ratios, positive and negative predictive values, with ABI readings dichotomised and Receiver Operating Curve analysis using both univariable and multivariable logistic regression. SETTING: Primary care in metropolitan and rural Victoria, Australia between October 2009 and November 2010. PARTICIPANTS: 250 persons with cardiovascular disease (CVD) or at high risk (three or more risk factors) of CVD. RESULTS: Despite a strong association between the two method's measurements of ABI there was poor agreement with 95% of readings within ±0.4 of the 0.9 ABI cut point. The multivariable C statistic of diagnosis of PAD was 0.89. Other diagnostic measures were sensitivity 62%, specificity 92%, positive predictive value 67%, negative predictive value 90%, accuracy 85%, positive likelihood ratio 7.3 and the negative likelihood ratio 0.42. CONCLUSIONS: Oscillometric ABI measures by primary care nurses on a population with a 22% prevalence of PAD lacked sufficient agreement with conventional measures to be recommended for routine diagnosis of PAD. This pragmatic method may however be used as a screening tool high-risk and overt CVD patients in primary care as it can reliably exclude the condition.
format Online
Article
Text
id pubmed-3488728
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-34887282012-11-05 Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study Nelson, Mark R Quinn, Stephen Winzenberg, Tania M Howes, Faline Shiel, Louise Reid, Christopher M BMJ Open General practice / Family practice OBJECTIVES: To determine the level of agreement between a ‘conventional’ Ankle-Brachial Index (ABI) measurement (using Doppler and mercury sphygmomanometer taken by a research nurse) and a ‘pragmatic’ ABI measure (using an oscillometric device taken by a practice nurse) in primary care. To ascertain the utility of a pragmatic ABI measure for the diagnosis of peripheral arterial disease (PAD) in primary care. DESIGN: Cross-sectional validation and diagnostic accuracy study. Descriptive analyses were used to investigate the agreement between the two procedures using the Bland and Altman method to determine whether the correlation between ABI readings varied systematically. Diagnostic accuracy was assessed via sensitivity, specificity, accuracy, likelihood ratios, positive and negative predictive values, with ABI readings dichotomised and Receiver Operating Curve analysis using both univariable and multivariable logistic regression. SETTING: Primary care in metropolitan and rural Victoria, Australia between October 2009 and November 2010. PARTICIPANTS: 250 persons with cardiovascular disease (CVD) or at high risk (three or more risk factors) of CVD. RESULTS: Despite a strong association between the two method's measurements of ABI there was poor agreement with 95% of readings within ±0.4 of the 0.9 ABI cut point. The multivariable C statistic of diagnosis of PAD was 0.89. Other diagnostic measures were sensitivity 62%, specificity 92%, positive predictive value 67%, negative predictive value 90%, accuracy 85%, positive likelihood ratio 7.3 and the negative likelihood ratio 0.42. CONCLUSIONS: Oscillometric ABI measures by primary care nurses on a population with a 22% prevalence of PAD lacked sufficient agreement with conventional measures to be recommended for routine diagnosis of PAD. This pragmatic method may however be used as a screening tool high-risk and overt CVD patients in primary care as it can reliably exclude the condition. BMJ Publishing Group 2012 2012-10-25 /pmc/articles/PMC3488728/ /pubmed/23100446 http://dx.doi.org/10.1136/bmjopen-2012-001689 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/ and http://creativecommons.org/licenses/by-nc/2.0/legalcode.
spellingShingle General practice / Family practice
Nelson, Mark R
Quinn, Stephen
Winzenberg, Tania M
Howes, Faline
Shiel, Louise
Reid, Christopher M
Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title_full Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title_fullStr Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title_full_unstemmed Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title_short Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
title_sort ankle-brachial index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
topic General practice / Family practice
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3488728/
https://www.ncbi.nlm.nih.gov/pubmed/23100446
http://dx.doi.org/10.1136/bmjopen-2012-001689
work_keys_str_mv AT nelsonmarkr anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy
AT quinnstephen anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy
AT winzenbergtaniam anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy
AT howesfaline anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy
AT shiellouise anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy
AT reidchristopherm anklebrachialindexdeterminationandperipheralarterialdiseasediagnosisbyanoscillometricbloodpressuredeviceinprimarycarevalidationanddiagnosticaccuracystudy