Cargando…

Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas

BACKGROUND: Using high-resolution ultrasonography (US) to measure the median nerve cross-sectional areas (CSAs) such as in the “inching test” conducted in nerve conduction studies is a valuable tool to assess carpal tunnel syndrome (CTS). However, using this US measurement method to assess the media...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Shu-Fang, Huang, Chi-Ren, Tsai, Nai-Wen, Chang, Chiung-Chih, Lu, Cheng-Hsien, Chuang, Yao-Chung, Chang, Wen-Neng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3490711/
https://www.ncbi.nlm.nih.gov/pubmed/22768921
http://dx.doi.org/10.1186/1471-2342-12-15
_version_ 1782248854927704064
author Chen, Shu-Fang
Huang, Chi-Ren
Tsai, Nai-Wen
Chang, Chiung-Chih
Lu, Cheng-Hsien
Chuang, Yao-Chung
Chang, Wen-Neng
author_facet Chen, Shu-Fang
Huang, Chi-Ren
Tsai, Nai-Wen
Chang, Chiung-Chih
Lu, Cheng-Hsien
Chuang, Yao-Chung
Chang, Wen-Neng
author_sort Chen, Shu-Fang
collection PubMed
description BACKGROUND: Using high-resolution ultrasonography (US) to measure the median nerve cross-sectional areas (CSAs) such as in the “inching test” conducted in nerve conduction studies is a valuable tool to assess carpal tunnel syndrome (CTS). However, using this US measurement method to assess the median nerve CSA in diabetic patients with CTS has rarely been reported. Therefore, we used this US measurement method in this study to measure median nerve CSAs and to compare the CSAs of idiopathic, diabetic and diabetic polyneuropathy (DPN) patients with CTS. METHODS: 124 hands belonging to 89 participants were included and assigned into four groups: control (32), idiopathic (38), diabetic (38) and DPN (16) CTS. In the latter two groups, only patients with mild and moderately severe CTS were included. The median nerve CSAs were measured at 8 points marked as i4, i3, i2, i1, w, o1, o2, and o3 in the inching test. The measured CSAs in each group of participants were compared. RESULTS: Compared with the CSAs of the control group, enlarged CSAs were found in the idiopathic, diabetic and DPN CTS groups. The CSAs were larger at i4, i3 and i2 in the diabetic CTS group compared to the idiopathic CTS group. The CSAs measured at the i1 and w levels of the DPN CTS group were smaller than those of the diabetic CTS group. In the diabetic CTS group, the cut-off values of CSAs measured at the inlet, wrist crease, and outlet were 15.3 mm(2), 13.4 mm(2) and 10.0 mm(2), respectively, and 14.0 mm(2), 12.5 mm(2) and 10.5 mm(2), respectively, in the DPN CTS group. CONCLUSIONS: Compared with the median nerve CSAs of the control and idiopathic CTS groups, the median nerve CSAs of the diabetic patients with CTS were significantly enlarged. However, compared with the diabetic CTS group, the CSAs were significantly smaller in the DPN CTS group. This US 8-point measurement method can be of value as an important complementary tool for CTS studies and diagnosis among diabetic patients.
format Online
Article
Text
id pubmed-3490711
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34907112012-11-07 Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas Chen, Shu-Fang Huang, Chi-Ren Tsai, Nai-Wen Chang, Chiung-Chih Lu, Cheng-Hsien Chuang, Yao-Chung Chang, Wen-Neng BMC Med Imaging Research Article BACKGROUND: Using high-resolution ultrasonography (US) to measure the median nerve cross-sectional areas (CSAs) such as in the “inching test” conducted in nerve conduction studies is a valuable tool to assess carpal tunnel syndrome (CTS). However, using this US measurement method to assess the median nerve CSA in diabetic patients with CTS has rarely been reported. Therefore, we used this US measurement method in this study to measure median nerve CSAs and to compare the CSAs of idiopathic, diabetic and diabetic polyneuropathy (DPN) patients with CTS. METHODS: 124 hands belonging to 89 participants were included and assigned into four groups: control (32), idiopathic (38), diabetic (38) and DPN (16) CTS. In the latter two groups, only patients with mild and moderately severe CTS were included. The median nerve CSAs were measured at 8 points marked as i4, i3, i2, i1, w, o1, o2, and o3 in the inching test. The measured CSAs in each group of participants were compared. RESULTS: Compared with the CSAs of the control group, enlarged CSAs were found in the idiopathic, diabetic and DPN CTS groups. The CSAs were larger at i4, i3 and i2 in the diabetic CTS group compared to the idiopathic CTS group. The CSAs measured at the i1 and w levels of the DPN CTS group were smaller than those of the diabetic CTS group. In the diabetic CTS group, the cut-off values of CSAs measured at the inlet, wrist crease, and outlet were 15.3 mm(2), 13.4 mm(2) and 10.0 mm(2), respectively, and 14.0 mm(2), 12.5 mm(2) and 10.5 mm(2), respectively, in the DPN CTS group. CONCLUSIONS: Compared with the median nerve CSAs of the control and idiopathic CTS groups, the median nerve CSAs of the diabetic patients with CTS were significantly enlarged. However, compared with the diabetic CTS group, the CSAs were significantly smaller in the DPN CTS group. This US 8-point measurement method can be of value as an important complementary tool for CTS studies and diagnosis among diabetic patients. BioMed Central 2012-07-07 /pmc/articles/PMC3490711/ /pubmed/22768921 http://dx.doi.org/10.1186/1471-2342-12-15 Text en Copyright ©2012 Chen et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chen, Shu-Fang
Huang, Chi-Ren
Tsai, Nai-Wen
Chang, Chiung-Chih
Lu, Cheng-Hsien
Chuang, Yao-Chung
Chang, Wen-Neng
Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title_full Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title_fullStr Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title_full_unstemmed Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title_short Ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
title_sort ultrasonographic assessment of carpal tunnel syndrome of mild and moderate severity in diabetic patients by using an 8-point measurement of median nerve cross-sectional areas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3490711/
https://www.ncbi.nlm.nih.gov/pubmed/22768921
http://dx.doi.org/10.1186/1471-2342-12-15
work_keys_str_mv AT chenshufang ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT huangchiren ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT tsainaiwen ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT changchiungchih ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT luchenghsien ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT chuangyaochung ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas
AT changwenneng ultrasonographicassessmentofcarpaltunnelsyndromeofmildandmoderateseverityindiabeticpatientsbyusingan8pointmeasurementofmediannervecrosssectionalareas