Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery
BACKGROUND: Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transva...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3490917/ https://www.ncbi.nlm.nih.gov/pubmed/22970933 http://dx.doi.org/10.1186/1471-2393-12-95 |
_version_ | 1782248902930464768 |
---|---|
author | Murphy, Deirdre J Burke, Gerard Montgomery, Alan A Ramphul, Meenakshi |
author_facet | Murphy, Deirdre J Burke, Gerard Montgomery, Alan A Ramphul, Meenakshi |
author_sort | Murphy, Deirdre J |
collection | PubMed |
description | BACKGROUND: Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice. METHODS/DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha. DISCUSSION: It is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries. TRIAL REGISTRATION: Current Controlled Trials ISRCTN72230496 |
format | Online Article Text |
id | pubmed-3490917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34909172012-11-07 Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery Murphy, Deirdre J Burke, Gerard Montgomery, Alan A Ramphul, Meenakshi BMC Pregnancy Childbirth Study Protocol BACKGROUND: Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 – 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice. METHODS/DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha. DISCUSSION: It is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries. TRIAL REGISTRATION: Current Controlled Trials ISRCTN72230496 BioMed Central 2012-09-13 /pmc/articles/PMC3490917/ /pubmed/22970933 http://dx.doi.org/10.1186/1471-2393-12-95 Text en Copyright ©2012 Murphy et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Study Protocol Murphy, Deirdre J Burke, Gerard Montgomery, Alan A Ramphul, Meenakshi Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title | Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title_full | Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title_fullStr | Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title_full_unstemmed | Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title_short | Study Protocol. IDUS – Instrumental delivery & ultrasound. A multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
title_sort | study protocol. idus – instrumental delivery & ultrasound. a multi-centre randomised controlled trial of ultrasound assessment of the fetal head position versus standard care as an approach to prevent morbidity at instrumental delivery |
topic | Study Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3490917/ https://www.ncbi.nlm.nih.gov/pubmed/22970933 http://dx.doi.org/10.1186/1471-2393-12-95 |
work_keys_str_mv | AT murphydeirdrej studyprotocolidusinstrumentaldeliveryultrasoundamulticentrerandomisedcontrolledtrialofultrasoundassessmentofthefetalheadpositionversusstandardcareasanapproachtopreventmorbidityatinstrumentaldelivery AT burkegerard studyprotocolidusinstrumentaldeliveryultrasoundamulticentrerandomisedcontrolledtrialofultrasoundassessmentofthefetalheadpositionversusstandardcareasanapproachtopreventmorbidityatinstrumentaldelivery AT montgomeryalana studyprotocolidusinstrumentaldeliveryultrasoundamulticentrerandomisedcontrolledtrialofultrasoundassessmentofthefetalheadpositionversusstandardcareasanapproachtopreventmorbidityatinstrumentaldelivery AT ramphulmeenakshi studyprotocolidusinstrumentaldeliveryultrasoundamulticentrerandomisedcontrolledtrialofultrasoundassessmentofthefetalheadpositionversusstandardcareasanapproachtopreventmorbidityatinstrumentaldelivery |