Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report
INTRODUCTION: Interprosthetic fractures of the humerus are rare. Revisions of total elbow arthroplasty components in these cases are difficult. We report the first case of a patient with hemophilia who underwent a revision with a tibial allograft prosthetic composite without the need for hardware au...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3492012/ https://www.ncbi.nlm.nih.gov/pubmed/23009283 http://dx.doi.org/10.1186/1752-1947-6-319 |
_version_ | 1782249037013975040 |
---|---|
author | LeBlanc, Justin Puloski, Shannon Hildebrand, Kevin |
author_facet | LeBlanc, Justin Puloski, Shannon Hildebrand, Kevin |
author_sort | LeBlanc, Justin |
collection | PubMed |
description | INTRODUCTION: Interprosthetic fractures of the humerus are rare. Revisions of total elbow arthroplasty components in these cases are difficult. We report the first case of a patient with hemophilia who underwent a revision with a tibial allograft prosthetic composite without the need for hardware augmentation. CASE PRESENTATION: A 43-year-old Caucasian man with a history of hemophilia and transfusion-related human immunodeficiency virus and hepatitis B and C presented with an interprosthetic fracture of his humerus after months of pain between his total elbow and total shoulder arthroplasties. Because of the poor remaining bone stock available in his distal humerus, a revision using a barrel-staved tibial allograft prosthetic composite was performed. Our patients’ factor VIII level was optimized before the operation and he suffered no major long-term complications at 28 months. His only complication was an incomplete radial nerve palsy that ultimately recovered and left him with some numbness on the dorsum of his hand. CONCLUSION: Careful use of an allograft prosthetic composite is a very reasonable option when a patient experiences an interprosthetic fracture. We have successfully performed revision total elbow arthroplasty for a patient with hemophilia with an interprosthetic fracture using a tibial allograft and no additional fixation, which resulted in his return to full activities of daily living, minimal pain and full incorporation of the allograft to host bone. |
format | Online Article Text |
id | pubmed-3492012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34920122012-11-08 Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report LeBlanc, Justin Puloski, Shannon Hildebrand, Kevin J Med Case Rep Case Report INTRODUCTION: Interprosthetic fractures of the humerus are rare. Revisions of total elbow arthroplasty components in these cases are difficult. We report the first case of a patient with hemophilia who underwent a revision with a tibial allograft prosthetic composite without the need for hardware augmentation. CASE PRESENTATION: A 43-year-old Caucasian man with a history of hemophilia and transfusion-related human immunodeficiency virus and hepatitis B and C presented with an interprosthetic fracture of his humerus after months of pain between his total elbow and total shoulder arthroplasties. Because of the poor remaining bone stock available in his distal humerus, a revision using a barrel-staved tibial allograft prosthetic composite was performed. Our patients’ factor VIII level was optimized before the operation and he suffered no major long-term complications at 28 months. His only complication was an incomplete radial nerve palsy that ultimately recovered and left him with some numbness on the dorsum of his hand. CONCLUSION: Careful use of an allograft prosthetic composite is a very reasonable option when a patient experiences an interprosthetic fracture. We have successfully performed revision total elbow arthroplasty for a patient with hemophilia with an interprosthetic fracture using a tibial allograft and no additional fixation, which resulted in his return to full activities of daily living, minimal pain and full incorporation of the allograft to host bone. BioMed Central 2012-09-25 /pmc/articles/PMC3492012/ /pubmed/23009283 http://dx.doi.org/10.1186/1752-1947-6-319 Text en Copyright ©2012 LeBlanc et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report LeBlanc, Justin Puloski, Shannon Hildebrand, Kevin Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title | Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title_full | Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title_fullStr | Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title_full_unstemmed | Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title_short | Interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia A : a case report |
title_sort | interprosthetic humeral fracture revision using a tibial allograft total elbow prosthetic composite in a patient with hemophilia a : a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3492012/ https://www.ncbi.nlm.nih.gov/pubmed/23009283 http://dx.doi.org/10.1186/1752-1947-6-319 |
work_keys_str_mv | AT leblancjustin interprosthetichumeralfracturerevisionusingatibialallografttotalelbowprostheticcompositeinapatientwithhemophiliaaacasereport AT puloskishannon interprosthetichumeralfracturerevisionusingatibialallografttotalelbowprostheticcompositeinapatientwithhemophiliaaacasereport AT hildebrandkevin interprosthetichumeralfracturerevisionusingatibialallografttotalelbowprostheticcompositeinapatientwithhemophiliaaacasereport |