Cargando…

Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose

OBJECTIVE: In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yi-Wei, Yang, Ching-Ching, Mok, Greta S. P., Law, Wei-Yip, Su, Cheng-Tau, Wu, Tung-Hsin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3492273/
https://www.ncbi.nlm.nih.gov/pubmed/23145126
http://dx.doi.org/10.1371/journal.pone.0049212
_version_ 1782249097478012928
author Lee, Yi-Wei
Yang, Ching-Ching
Mok, Greta S. P.
Law, Wei-Yip
Su, Cheng-Tau
Wu, Tung-Hsin
author_facet Lee, Yi-Wei
Yang, Ching-Ching
Mok, Greta S. P.
Law, Wei-Yip
Su, Cheng-Tau
Wu, Tung-Hsin
author_sort Lee, Yi-Wei
collection PubMed
description OBJECTIVE: In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice CT. METHODS: We studied 124 grafts with 577 segments in 64 patients with a heart rate (HR) <85 bpm who underwent CT coronary angiography (CTCA); 34 patients with RGH-CTCA and 30 patients with PGA-CTCA. The image quality of the bypass grafts was assessed by a 5-point scale (1 = excellent to 5 = non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Other objective image quality indices such as noise, signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) were assessed. Radiation doses were also compared. RESULTS: Patient characteristics of the two groups were well matched except HR. The HR of the PGA group was lower than that of the RGH group (62.0±5.0 vs. 65.7±7.4). For both groups, over 90% of segments received excellent or good image quality scores and none was non-evaluative. The image quality generally degraded as graft segment approached to distal anastomosis regardless of techniques and graft types. Image quality scores of the PGA group were better than those of the RGH group (1.51±0.53 vs. 1.73±0.62; p<0.001). There was no significantly difference of objective image quality between two techniques, and the effective radiation dose was significantly lower in the PGA group (7.0±1.2 mSv) than that of the RGH group (20.0±4.6 mSv) (p<0.001), with a 65.0% dose reduction. CONCLUSIONS: Following bypass surgery, 256-slice PGA-CTCA is superior to RGH-CTCA in limiting the radiation dose and obtaining better image quality for bypass grafts.
format Online
Article
Text
id pubmed-3492273
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34922732012-11-09 Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose Lee, Yi-Wei Yang, Ching-Ching Mok, Greta S. P. Law, Wei-Yip Su, Cheng-Tau Wu, Tung-Hsin PLoS One Research Article OBJECTIVE: In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice CT. METHODS: We studied 124 grafts with 577 segments in 64 patients with a heart rate (HR) <85 bpm who underwent CT coronary angiography (CTCA); 34 patients with RGH-CTCA and 30 patients with PGA-CTCA. The image quality of the bypass grafts was assessed by a 5-point scale (1 = excellent to 5 = non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Other objective image quality indices such as noise, signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) were assessed. Radiation doses were also compared. RESULTS: Patient characteristics of the two groups were well matched except HR. The HR of the PGA group was lower than that of the RGH group (62.0±5.0 vs. 65.7±7.4). For both groups, over 90% of segments received excellent or good image quality scores and none was non-evaluative. The image quality generally degraded as graft segment approached to distal anastomosis regardless of techniques and graft types. Image quality scores of the PGA group were better than those of the RGH group (1.51±0.53 vs. 1.73±0.62; p<0.001). There was no significantly difference of objective image quality between two techniques, and the effective radiation dose was significantly lower in the PGA group (7.0±1.2 mSv) than that of the RGH group (20.0±4.6 mSv) (p<0.001), with a 65.0% dose reduction. CONCLUSIONS: Following bypass surgery, 256-slice PGA-CTCA is superior to RGH-CTCA in limiting the radiation dose and obtaining better image quality for bypass grafts. Public Library of Science 2012-11-07 /pmc/articles/PMC3492273/ /pubmed/23145126 http://dx.doi.org/10.1371/journal.pone.0049212 Text en © 2012 Lee et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lee, Yi-Wei
Yang, Ching-Ching
Mok, Greta S. P.
Law, Wei-Yip
Su, Cheng-Tau
Wu, Tung-Hsin
Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title_full Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title_fullStr Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title_full_unstemmed Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title_short Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose
title_sort prospectively versus retrospectively ecg-gated 256-slice ct angiography to assess coronary artery bypass grafts — comparison of image quality and radiation dose
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3492273/
https://www.ncbi.nlm.nih.gov/pubmed/23145126
http://dx.doi.org/10.1371/journal.pone.0049212
work_keys_str_mv AT leeyiwei prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose
AT yangchingching prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose
AT mokgretasp prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose
AT lawweiyip prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose
AT suchengtau prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose
AT wutunghsin prospectivelyversusretrospectivelyecggated256slicectangiographytoassesscoronaryarterybypassgraftscomparisonofimagequalityandradiationdose