Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths
Standoff detection measuring the fluorescence spectra of seven different biological agents excited by 294 nm as well as 355 nm wavelength laser pulses has been undertaken. The biological warfare agent simulants were released in a semi-closed aerosol chamber at 210 m standoff distance and excited by...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493216/ https://www.ncbi.nlm.nih.gov/pubmed/23162732 http://dx.doi.org/10.1364/BOE.3.002964 |
_version_ | 1782249220665769984 |
---|---|
author | Farsund, Øystein Rustad, Gunnar Skogan, Gunnar |
author_facet | Farsund, Øystein Rustad, Gunnar Skogan, Gunnar |
author_sort | Farsund, Øystein |
collection | PubMed |
description | Standoff detection measuring the fluorescence spectra of seven different biological agents excited by 294 nm as well as 355 nm wavelength laser pulses has been undertaken. The biological warfare agent simulants were released in a semi-closed aerosol chamber at 210 m standoff distance and excited by light at either of the two wavelengths using the same instrument. Significant differences in several of the agents’ fluorescence response were seen at the two wavelengths. The anthrax simulants’ fluorescence responses were almost an order of magnitude stronger at the shorter wavelength excitation. However, most importantly, the fluorescence spectra were significantly more dissimilar at 294 nm than at 355 nm excitation with ~7 nm spectral resolution. This indicates that classification of the substances should be possible with a lower error rate for standoff detection using 294 nm rather than 355 nm excitation wavelength, or even better, utilizing both. |
format | Online Article Text |
id | pubmed-3493216 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-34932162012-11-16 Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths Farsund, Øystein Rustad, Gunnar Skogan, Gunnar Biomed Opt Express Biodefense and Bioterrorism Standoff detection measuring the fluorescence spectra of seven different biological agents excited by 294 nm as well as 355 nm wavelength laser pulses has been undertaken. The biological warfare agent simulants were released in a semi-closed aerosol chamber at 210 m standoff distance and excited by light at either of the two wavelengths using the same instrument. Significant differences in several of the agents’ fluorescence response were seen at the two wavelengths. The anthrax simulants’ fluorescence responses were almost an order of magnitude stronger at the shorter wavelength excitation. However, most importantly, the fluorescence spectra were significantly more dissimilar at 294 nm than at 355 nm excitation with ~7 nm spectral resolution. This indicates that classification of the substances should be possible with a lower error rate for standoff detection using 294 nm rather than 355 nm excitation wavelength, or even better, utilizing both. Optical Society of America 2012-10-24 /pmc/articles/PMC3493216/ /pubmed/23162732 http://dx.doi.org/10.1364/BOE.3.002964 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Biodefense and Bioterrorism Farsund, Øystein Rustad, Gunnar Skogan, Gunnar Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title | Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title_full | Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title_fullStr | Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title_full_unstemmed | Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title_short | Standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
title_sort | standoff detection of biological agents using laser induced fluorescence—a comparison of 294 nm and 355 nm excitation wavelengths |
topic | Biodefense and Bioterrorism |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493216/ https://www.ncbi.nlm.nih.gov/pubmed/23162732 http://dx.doi.org/10.1364/BOE.3.002964 |
work_keys_str_mv | AT farsundøystein standoffdetectionofbiologicalagentsusinglaserinducedfluorescenceacomparisonof294nmand355nmexcitationwavelengths AT rustadgunnar standoffdetectionofbiologicalagentsusinglaserinducedfluorescenceacomparisonof294nmand355nmexcitationwavelengths AT skogangunnar standoffdetectionofbiologicalagentsusinglaserinducedfluorescenceacomparisonof294nmand355nmexcitationwavelengths |