Cargando…

Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages

BACKGROUND: Titanium (TTN) cages have a higher modulus of elasticity when compared with polyetheretherketone (PEEK) cages. This suggests that TTN-cages could show more frequent cage subsidence after anterior cervical discectomy and fusion (ACDF) and therefore might lead to a higher loss of correctio...

Descripción completa

Detalles Bibliográficos
Autores principales: Cabraja, Mario, Oezdemir, Soner, Koeppen, Daniel, Kroppenstedt, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493386/
https://www.ncbi.nlm.nih.gov/pubmed/22978810
http://dx.doi.org/10.1186/1471-2474-13-172
_version_ 1782249257556770816
author Cabraja, Mario
Oezdemir, Soner
Koeppen, Daniel
Kroppenstedt, Stefan
author_facet Cabraja, Mario
Oezdemir, Soner
Koeppen, Daniel
Kroppenstedt, Stefan
author_sort Cabraja, Mario
collection PubMed
description BACKGROUND: Titanium (TTN) cages have a higher modulus of elasticity when compared with polyetheretherketone (PEEK) cages. This suggests that TTN-cages could show more frequent cage subsidence after anterior cervical discectomy and fusion (ACDF) and therefore might lead to a higher loss of correction. We compared the long term results of stand-alone PEEK- and TTN-cages in a comparable patient collective that was operated under identical operative settings. METHODS: From 2002 to 2007 154 patients underwent single-level ACDF for degenerative disc disease (DDD). Clinical and radiological outcome were assessed in 86 eligible patients after a mean of 28.4 months. 44 patients received a TTN- and 42 patients a PEEK-cage. RESULTS: Solid arthrodesis was found in 93.2% of the TTN-group and 88.1% of the PEEK-group. Cage subsidence was observed in 20.5% of the TTN- and 14.3% of the PEEK-group. A significant segmental lordotic correction was achieved by both cage-types. Even though a loss of correction was found at the last follow-up in both groups, it did not reach the level of statistical significance. Statistical analysis of these results revealed no differences between the TTN- and PEEK-group. When assessed with the neck disability index (NDI), the visual analogue scale (VAS) of neck and arm pain and Odom’s criteria the clinical data showed no significant differences between the groups. CONCLUSIONS: Clinical and radiological outcomes of ACDF with TTN- or PEEK-cages do not appear to be influenced by the chosen synthetic graft. The modulus of elasticity represents only one of many physical properties of a cage. Design, shape, size, surface architecture of a cage as well as bone density, endplate preparation and applied distraction during surgery need to be considered as further important factors.
format Online
Article
Text
id pubmed-3493386
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34933862012-11-09 Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages Cabraja, Mario Oezdemir, Soner Koeppen, Daniel Kroppenstedt, Stefan BMC Musculoskelet Disord Research Article BACKGROUND: Titanium (TTN) cages have a higher modulus of elasticity when compared with polyetheretherketone (PEEK) cages. This suggests that TTN-cages could show more frequent cage subsidence after anterior cervical discectomy and fusion (ACDF) and therefore might lead to a higher loss of correction. We compared the long term results of stand-alone PEEK- and TTN-cages in a comparable patient collective that was operated under identical operative settings. METHODS: From 2002 to 2007 154 patients underwent single-level ACDF for degenerative disc disease (DDD). Clinical and radiological outcome were assessed in 86 eligible patients after a mean of 28.4 months. 44 patients received a TTN- and 42 patients a PEEK-cage. RESULTS: Solid arthrodesis was found in 93.2% of the TTN-group and 88.1% of the PEEK-group. Cage subsidence was observed in 20.5% of the TTN- and 14.3% of the PEEK-group. A significant segmental lordotic correction was achieved by both cage-types. Even though a loss of correction was found at the last follow-up in both groups, it did not reach the level of statistical significance. Statistical analysis of these results revealed no differences between the TTN- and PEEK-group. When assessed with the neck disability index (NDI), the visual analogue scale (VAS) of neck and arm pain and Odom’s criteria the clinical data showed no significant differences between the groups. CONCLUSIONS: Clinical and radiological outcomes of ACDF with TTN- or PEEK-cages do not appear to be influenced by the chosen synthetic graft. The modulus of elasticity represents only one of many physical properties of a cage. Design, shape, size, surface architecture of a cage as well as bone density, endplate preparation and applied distraction during surgery need to be considered as further important factors. BioMed Central 2012-09-14 /pmc/articles/PMC3493386/ /pubmed/22978810 http://dx.doi.org/10.1186/1471-2474-13-172 Text en Copyright ©2012 Cabraja et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Cabraja, Mario
Oezdemir, Soner
Koeppen, Daniel
Kroppenstedt, Stefan
Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title_full Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title_fullStr Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title_full_unstemmed Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title_short Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
title_sort anterior cervical discectomy and fusion: comparison of titanium and polyetheretherketone cages
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493386/
https://www.ncbi.nlm.nih.gov/pubmed/22978810
http://dx.doi.org/10.1186/1471-2474-13-172
work_keys_str_mv AT cabrajamario anteriorcervicaldiscectomyandfusioncomparisonoftitaniumandpolyetheretherketonecages
AT oezdemirsoner anteriorcervicaldiscectomyandfusioncomparisonoftitaniumandpolyetheretherketonecages
AT koeppendaniel anteriorcervicaldiscectomyandfusioncomparisonoftitaniumandpolyetheretherketonecages
AT kroppenstedtstefan anteriorcervicaldiscectomyandfusioncomparisonoftitaniumandpolyetheretherketonecages