Cargando…
Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation
BACKGROUND/AIMS: Various strategies to expand the ablation zone have been attempted using hepatic radiofrequency ablation (RFA). The optimal strategy, however, is unknown. We compared hepatic RFA with an internally cooled wet (ICW) electrode and vascular inflow occlusion. METHODS: Eight dogs were as...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Pancreatobiliary Association; Korean Society of Gastrointestinal Cancer
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493728/ https://www.ncbi.nlm.nih.gov/pubmed/23170152 http://dx.doi.org/10.5009/gnl.2012.6.4.471 |
_version_ | 1782249314770223104 |
---|---|
author | Park, Mi-Hyun Cho, June-Sik Shin, Byung Seok Jeon, Gyeong Sik Lee, Byungmo Lee, Kichang |
author_facet | Park, Mi-Hyun Cho, June-Sik Shin, Byung Seok Jeon, Gyeong Sik Lee, Byungmo Lee, Kichang |
author_sort | Park, Mi-Hyun |
collection | PubMed |
description | BACKGROUND/AIMS: Various strategies to expand the ablation zone have been attempted using hepatic radiofrequency ablation (RFA). The optimal strategy, however, is unknown. We compared hepatic RFA with an internally cooled wet (ICW) electrode and vascular inflow occlusion. METHODS: Eight dogs were assigned to one of three groups: only RFA using an internally cooled electrode (group A), RFA using an ICW electrode (group B), and RFA using an internally cooled electrode with the Pringle maneuver (group C). The ablation zone diameters were measured on the gross specimens, and the volume of the ablation zone was calculated. RESULTS: The ablation zone volume was greatest in group B (1.82±1.23 cm(3)), followed by group C (1.22±0.47 cm(3)), and then group A (0.48±0.33 cm(3)). The volumes for group B were significantly larger than the volumes for group A (p=0.030). There was no significant difference in the volumes between groups A and C (p=0.079) and between groups B and C (p=0.827). CONCLUSIONS: Both the usage of an ICW electrode and hepatic vascular occlusion effectively expanded the ablation zone. The use of an ICW electrode induced a larger ablation zone with easy handling compared with using hepatic vascular occlusion, although this difference was not statistically significant. |
format | Online Article Text |
id | pubmed-3493728 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Pancreatobiliary Association; Korean Society of Gastrointestinal Cancer |
record_format | MEDLINE/PubMed |
spelling | pubmed-34937282012-11-20 Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation Park, Mi-Hyun Cho, June-Sik Shin, Byung Seok Jeon, Gyeong Sik Lee, Byungmo Lee, Kichang Gut Liver Original Article BACKGROUND/AIMS: Various strategies to expand the ablation zone have been attempted using hepatic radiofrequency ablation (RFA). The optimal strategy, however, is unknown. We compared hepatic RFA with an internally cooled wet (ICW) electrode and vascular inflow occlusion. METHODS: Eight dogs were assigned to one of three groups: only RFA using an internally cooled electrode (group A), RFA using an ICW electrode (group B), and RFA using an internally cooled electrode with the Pringle maneuver (group C). The ablation zone diameters were measured on the gross specimens, and the volume of the ablation zone was calculated. RESULTS: The ablation zone volume was greatest in group B (1.82±1.23 cm(3)), followed by group C (1.22±0.47 cm(3)), and then group A (0.48±0.33 cm(3)). The volumes for group B were significantly larger than the volumes for group A (p=0.030). There was no significant difference in the volumes between groups A and C (p=0.079) and between groups B and C (p=0.827). CONCLUSIONS: Both the usage of an ICW electrode and hepatic vascular occlusion effectively expanded the ablation zone. The use of an ICW electrode induced a larger ablation zone with easy handling compared with using hepatic vascular occlusion, although this difference was not statistically significant. The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Pancreatobiliary Association; Korean Society of Gastrointestinal Cancer 2012-10 2012-08-07 /pmc/articles/PMC3493728/ /pubmed/23170152 http://dx.doi.org/10.5009/gnl.2012.6.4.471 Text en Copyright © 2012 by the Korean Society of Gastroenterology, the Korean Society of Gastrointestinal Endoscopy, the Korean Society of Neurogastroenterology and Motility, Korean College of Helicobacter and Upper Gastrointestinal Research, Korean Association for the Study of Intestinal Diseases, the Korean Association for the Study of the Liver, Korean Pancreatobiliary Association, and Korean Society of Gastrointestinal Cancer http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Mi-Hyun Cho, June-Sik Shin, Byung Seok Jeon, Gyeong Sik Lee, Byungmo Lee, Kichang Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title | Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title_full | Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title_fullStr | Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title_full_unstemmed | Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title_short | Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation |
title_sort | comparison of internally cooled wet electrode and hepatic vascular inflow occlusion method for hepatic radiofrequency ablation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3493728/ https://www.ncbi.nlm.nih.gov/pubmed/23170152 http://dx.doi.org/10.5009/gnl.2012.6.4.471 |
work_keys_str_mv | AT parkmihyun comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation AT chojunesik comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation AT shinbyungseok comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation AT jeongyeongsik comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation AT leebyungmo comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation AT leekichang comparisonofinternallycooledwetelectrodeandhepaticvascularinflowocclusionmethodforhepaticradiofrequencyablation |