Cargando…

A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures

The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveri...

Descripción completa

Detalles Bibliográficos
Autores principales: WANG, WULIAN, WU, GUANGWEN, SHEN, FUER, ZHANG, YIYUAN, LIU, XIANXIANG
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3494112/
https://www.ncbi.nlm.nih.gov/pubmed/23226778
http://dx.doi.org/10.3892/etm.2012.731
_version_ 1782249362340970496
author WANG, WULIAN
WU, GUANGWEN
SHEN, FUER
ZHANG, YIYUAN
LIU, XIANXIANG
author_facet WANG, WULIAN
WU, GUANGWEN
SHEN, FUER
ZHANG, YIYUAN
LIU, XIANXIANG
author_sort WANG, WULIAN
collection PubMed
description The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveric elbow joints were used as transverse, oblique and comminuted olecranon fracture models. Five techniques of internal fixation were investigated: circular wiring, figure of eight wiring, circular plus figure of eight wiring, Kirschner wire (K-wire) and screw fixation. The elbow joints were flexed at 90°. The fixation performance was tested using a high-precision displacement sensor. Displacement-load curves revealed that the strength of internal fixation was weakest when using circular wiring alone and that circular wiring plus figure of eight wiring fixation was stronger than that of figure of eight wiring or screw fixation. The difference was statistically significant (P<0.05). There were no significant differences between circular wiring plus figure of eight wiring fixation and K-wire fixation in the transverse and oblique fracture models (P>0.05). However, figure of eight plus circular wiring fixation was superior to K-wire fixation in the comminuted fracture model, with a tensile force of 67.42±2.17 vs. 58.52±2.17 N, respectively (P<0.05). All 152 patients with olecranon fractures who received circular wiring plus figure of eight wiring fixation recovered and 108 were included in the follow-up for an average of 12 months. The rate of excellent/fairly good recovery was 98.10%. Due to its reliability, simple surgery, lower invasiveness and lower cost, figure of eight plus circular wiring fixation is an ideal choice for the internal fixation of olecranon fractures, particularly comminuted fractures, compared with circular wiring, figure of eight wiring or screw fixation.
format Online
Article
Text
id pubmed-3494112
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-34941122012-12-06 A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures WANG, WULIAN WU, GUANGWEN SHEN, FUER ZHANG, YIYUAN LIU, XIANXIANG Exp Ther Med Articles The aim of the present study was to evaluate the stability of the figure of eight plus circular wiring fixation technique compared with four common internal fixation techniques and to provide experimental data for the selection of internal fixation techniques clinically. A total of 20 fresh cadaveric elbow joints were used as transverse, oblique and comminuted olecranon fracture models. Five techniques of internal fixation were investigated: circular wiring, figure of eight wiring, circular plus figure of eight wiring, Kirschner wire (K-wire) and screw fixation. The elbow joints were flexed at 90°. The fixation performance was tested using a high-precision displacement sensor. Displacement-load curves revealed that the strength of internal fixation was weakest when using circular wiring alone and that circular wiring plus figure of eight wiring fixation was stronger than that of figure of eight wiring or screw fixation. The difference was statistically significant (P<0.05). There were no significant differences between circular wiring plus figure of eight wiring fixation and K-wire fixation in the transverse and oblique fracture models (P>0.05). However, figure of eight plus circular wiring fixation was superior to K-wire fixation in the comminuted fracture model, with a tensile force of 67.42±2.17 vs. 58.52±2.17 N, respectively (P<0.05). All 152 patients with olecranon fractures who received circular wiring plus figure of eight wiring fixation recovered and 108 were included in the follow-up for an average of 12 months. The rate of excellent/fairly good recovery was 98.10%. Due to its reliability, simple surgery, lower invasiveness and lower cost, figure of eight plus circular wiring fixation is an ideal choice for the internal fixation of olecranon fractures, particularly comminuted fractures, compared with circular wiring, figure of eight wiring or screw fixation. D.A. Spandidos 2012-12 2012-09-01 /pmc/articles/PMC3494112/ /pubmed/23226778 http://dx.doi.org/10.3892/etm.2012.731 Text en Copyright © 2012, Spandidos Publications http://creativecommons.org/licenses/by/3.0 This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.
spellingShingle Articles
WANG, WULIAN
WU, GUANGWEN
SHEN, FUER
ZHANG, YIYUAN
LIU, XIANXIANG
A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title_full A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title_fullStr A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title_full_unstemmed A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title_short A biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
title_sort biomechanical experiment and clinical study of the use of figure of eight plus circular wiring fixation for the treatment of olecranon fractures
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3494112/
https://www.ncbi.nlm.nih.gov/pubmed/23226778
http://dx.doi.org/10.3892/etm.2012.731
work_keys_str_mv AT wangwulian abiomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT wuguangwen abiomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT shenfuer abiomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT zhangyiyuan abiomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT liuxianxiang abiomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT wangwulian biomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT wuguangwen biomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT shenfuer biomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT zhangyiyuan biomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures
AT liuxianxiang biomechanicalexperimentandclinicalstudyoftheuseoffigureofeightpluscircularwiringfixationforthetreatmentofolecranonfractures