Cargando…
Mitral valve restoration using the No-React(R) MitroFix™: a novel concept
BACKGROUND: Mitral Valve Repair (MVRP) has been shown to be significantly superior to Mitral Valve Replacement (MVR). Since the majority of repairs involve the Posterior Mitral Leaflet (PML) and not the Anterior Mitral Leaflet (AML), the monocuspidalisation of the Mitral Valve (MV) can be achieved w...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3494579/ https://www.ncbi.nlm.nih.gov/pubmed/22947441 http://dx.doi.org/10.1186/1749-8090-7-82 |
Sumario: | BACKGROUND: Mitral Valve Repair (MVRP) has been shown to be significantly superior to Mitral Valve Replacement (MVR). Since the majority of repairs involve the Posterior Mitral Leaflet (PML) and not the Anterior Mitral Leaflet (AML), the monocuspidalisation of the Mitral Valve (MV) can be achieved with a bio-posterior leaflet that imitates a closed PML. This approach may have the benefit of restoring the competence of the MV without reducing its effective orifice area. METHODS: We have used a new concept and device, the MitroFixTM, to correct MV regurgitation due to pathology of the PML. The device comes with functional sizers both of which have identical shape and size. This allows the surgeon to pre-test the success of the restoration. From December 2006 to October 2011, 51 MitroFixTM devices were implanted at three institutions. RESULTS: The mean age of the patients (32 males and 19 females) was 67.7 years. 37 of them were in NYHA class III or IV and all patients suffered from severe mitral valve regurgitation (MR). 31 patients underwent combined surgery. Successful implantation of the MitroFix™ device was performed in 51/53 patients.Mean cross-clamp time was 63.6 min (range: 29-118 min). Six patients had additional reconstructive procedures of the AML (chordae transfer, neo-chordae, triangular resection). At discharge, 33 patients showed no MR in the TTE and 17 patients exhibited trivial (I) or moderate (II) MR. The mean gradient was 4.0 mmHg and mean EOA was 2.52cm^2 (range: 1.5-4.0cm2). All patients were classified as being in NYHA class I or II. CONCLUSION: The MitroFixTM Mitral Valve Restoration Device is a new concept that offers an effective treatment of MR. The restoration of the mitral valve with the MitroFix™ device offers the advantage of preserving the AML and providing good coaptation with a prosthetic PML. Importantly, this preliminary evaluation indicates a mean effective orifice area ( EOA ) of 2.5cm2 in MV receiving a MitroFix™ device, witch is higher than EOA resulting from MVR or MVRP. The present study has also shown that severe regurgitation due to ischemic/rheumatic MR, endocarditis and complex prolapse of the PML are clear candidates for correction with the MitroFix™. Larger studies and a longer follow up period are needed to validate these promising results. |
---|