Cargando…

Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias

BACKGROUND: The diagnosis of malignant hematologic diseases has become increasingly complex during the last decade. It is based on the interpretation of results from different laboratory analyses, which range from microscopy to gene expression profiling. Recently, a method for the analysis of RNA ph...

Descripción completa

Detalles Bibliográficos
Autores principales: Fernandez, Paula, Solenthaler, Max, Spertini, Olivier, Quarroz, Stephane, Rovo, Alicia, Lovey, Pierre-Yves, Leoncini, Leda, Ruault-Jungblut, Sylvie, D’Asaro, Mathilde, Schaad, Olivier, Docquier, Mylène, Descombes, Patrick, Matthes, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3494663/
https://www.ncbi.nlm.nih.gov/pubmed/23152841
http://dx.doi.org/10.1371/journal.pone.0049010
_version_ 1782249426277892096
author Fernandez, Paula
Solenthaler, Max
Spertini, Olivier
Quarroz, Stephane
Rovo, Alicia
Lovey, Pierre-Yves
Leoncini, Leda
Ruault-Jungblut, Sylvie
D’Asaro, Mathilde
Schaad, Olivier
Docquier, Mylène
Descombes, Patrick
Matthes, Thomas
author_facet Fernandez, Paula
Solenthaler, Max
Spertini, Olivier
Quarroz, Stephane
Rovo, Alicia
Lovey, Pierre-Yves
Leoncini, Leda
Ruault-Jungblut, Sylvie
D’Asaro, Mathilde
Schaad, Olivier
Docquier, Mylène
Descombes, Patrick
Matthes, Thomas
author_sort Fernandez, Paula
collection PubMed
description BACKGROUND: The diagnosis of malignant hematologic diseases has become increasingly complex during the last decade. It is based on the interpretation of results from different laboratory analyses, which range from microscopy to gene expression profiling. Recently, a method for the analysis of RNA phenotypes has been developed, the nCounter technology (Nanostring® Technologies), which allows for simultaneous quantification of hundreds of RNA molecules in biological samples. We evaluated this technique in a Swiss multi-center study on eighty-six samples from acute leukemia patients. METHODS: mRNA and protein profiles were established for normal peripheral blood and bone marrow samples. Signal intensities of the various tested antigens with surface expression were similar to those found in previously performed Affymetrix microarray analyses. Acute leukemia samples were analyzed for a set of twenty-two validated antigens and the Pearson Correlation Coefficient for nCounter and flow cytometry results was calculated. RESULTS: Highly significant values between 0.40 and 0.97 were found for the twenty-two antigens tested. A second correlation analysis performed on a per sample basis resulted in concordant results between flow cytometry and nCounter in 44–100% of the antigens tested (mean = 76%), depending on the number of blasts present in a sample, the homogeneity of the blast population, and the type of leukemia (AML or ALL). CONCLUSIONS: The nCounter technology allows for fast and easy depiction of a mRNA profile from hematologic samples. This technology has the potential to become a valuable tool for the diagnosis of acute leukemias, in addition to multi-color flow cytometry.
format Online
Article
Text
id pubmed-3494663
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-34946632012-11-14 Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias Fernandez, Paula Solenthaler, Max Spertini, Olivier Quarroz, Stephane Rovo, Alicia Lovey, Pierre-Yves Leoncini, Leda Ruault-Jungblut, Sylvie D’Asaro, Mathilde Schaad, Olivier Docquier, Mylène Descombes, Patrick Matthes, Thomas PLoS One Research Article BACKGROUND: The diagnosis of malignant hematologic diseases has become increasingly complex during the last decade. It is based on the interpretation of results from different laboratory analyses, which range from microscopy to gene expression profiling. Recently, a method for the analysis of RNA phenotypes has been developed, the nCounter technology (Nanostring® Technologies), which allows for simultaneous quantification of hundreds of RNA molecules in biological samples. We evaluated this technique in a Swiss multi-center study on eighty-six samples from acute leukemia patients. METHODS: mRNA and protein profiles were established for normal peripheral blood and bone marrow samples. Signal intensities of the various tested antigens with surface expression were similar to those found in previously performed Affymetrix microarray analyses. Acute leukemia samples were analyzed for a set of twenty-two validated antigens and the Pearson Correlation Coefficient for nCounter and flow cytometry results was calculated. RESULTS: Highly significant values between 0.40 and 0.97 were found for the twenty-two antigens tested. A second correlation analysis performed on a per sample basis resulted in concordant results between flow cytometry and nCounter in 44–100% of the antigens tested (mean = 76%), depending on the number of blasts present in a sample, the homogeneity of the blast population, and the type of leukemia (AML or ALL). CONCLUSIONS: The nCounter technology allows for fast and easy depiction of a mRNA profile from hematologic samples. This technology has the potential to become a valuable tool for the diagnosis of acute leukemias, in addition to multi-color flow cytometry. Public Library of Science 2012-11-09 /pmc/articles/PMC3494663/ /pubmed/23152841 http://dx.doi.org/10.1371/journal.pone.0049010 Text en © 2012 Fernandez et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Fernandez, Paula
Solenthaler, Max
Spertini, Olivier
Quarroz, Stephane
Rovo, Alicia
Lovey, Pierre-Yves
Leoncini, Leda
Ruault-Jungblut, Sylvie
D’Asaro, Mathilde
Schaad, Olivier
Docquier, Mylène
Descombes, Patrick
Matthes, Thomas
Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title_full Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title_fullStr Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title_full_unstemmed Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title_short Using Digital RNA Counting and Flow Cytometry to Compare mRNA with Protein Expression in Acute Leukemias
title_sort using digital rna counting and flow cytometry to compare mrna with protein expression in acute leukemias
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3494663/
https://www.ncbi.nlm.nih.gov/pubmed/23152841
http://dx.doi.org/10.1371/journal.pone.0049010
work_keys_str_mv AT fernandezpaula usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT solenthalermax usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT spertiniolivier usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT quarrozstephane usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT rovoalicia usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT loveypierreyves usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT leoncinileda usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT ruaultjungblutsylvie usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT dasaromathilde usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT schaadolivier usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT docquiermylene usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT descombespatrick usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT matthesthomas usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias
AT usingdigitalrnacountingandflowcytometrytocomparemrnawithproteinexpressioninacuteleukemias